• Title/Summary/Keyword: MV image

Search Result 76, Processing Time 0.028 seconds

A Study on New Hierarchical Motion Compensation Pyramid Coding (새로운 계층적 이동 보상 피라미드 부호화 방식 연구)

  • 전준현
    • Journal of Broadcast Engineering
    • /
    • v.8 no.2
    • /
    • pp.181-197
    • /
    • 2003
  • Notion Compensation(MC) technique using Sub-Band Coding with the hierarchical structure is efficient to estimate real motion. In the hierarchical pyramid method, low-band MC pyramid method is popular, where the upper layer estimate the glover motion and next lower layer estimate the local motion. The low-band MC pyramid scheme has two problems. First, because the quantization errors at lower layer are accumulated when using coding and quantizing, it is impossible to search the exact Motion Vector(MV) Second, because of the top-down search problem in the hierarchical structure, MV mismatch in upper layer causes serious MV in lower layer So. we propose new hierarchical MC pyramid method based on edge classification. In this Paper, we show that the performance of proposed Pass-band motion compensation pyramid technique is better than low-band motion compensation pyramid. Also, in the pyramid motion estimation, we propose initial MV estimation scheme based on the edge-pattern classification. As a result, we find that PSNR was increased.

Adaptive Motion Vector Estimation Using the Regional Feature (영역별 특성을 이용한 적응적 움직임 벡터 추정 기법)

  • Park, Tae-Hee;Lee, Dong-Wook;Kim, Jae-Min;Kim, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.502-504
    • /
    • 1995
  • In video image compression, it is important to extract the exact notion information from image sequence in order to perform the data compression, the field rate conversion, and the motion compensated interpolation effectively. It is well known that the location of the smallest sum of absolute difference(SAD) does not always give the true motion vector(MV) since the MV obtained via full block search is often corrupted by noise. In this paper, we first classifies the input blocks into 3 categories : the background, the shade-motion, and the edge-motion. According to the characteristics of the classified blocks, multiple locations of relatively small SAD are searched with an adaptive search window by using the proposed method. The proposed method picks MVs among those candidates by using temporal correlation. Since temporal correlation reveals the noise level in a particular region of the video image sequence, we are able to reduce the search are very effectively.

  • PDF

The quantitative analysis by the image processing of sperm changes according to the radiation irradiation of white rat testicle (흰쥐 정소의 방사선 조사에 따른 정자변화의 영상처리에 의한 정량분석)

  • Na, Soo-Kyung;Kim, Sung-In;Lee, On-Seok
    • Journal of Digital Convergence
    • /
    • v.12 no.6
    • /
    • pp.433-438
    • /
    • 2014
  • This study aims to get more accurate and objective result by quantifying the result for the sperm changes through the quantitative analysis by the image processing based on the image obtained microscopically for the testicle cell and sperm change appeared with the passage of time when the radiation is irradiated to the white rat testicle. This study has targeted the white rat of 8 weeks lifespan, the X-ray of 6 MV with 1 time of 2 Gy has been irradiated to the whole body. The testicles of 5 rats at each test group immediately after irradiation, after 2 hours of irradiation, 4 hours, 8 hours and 24 hours has been respectively extracted targeting all 30 white rats of normal control group not irradiated by the radiation and the test group. The state of testicle cell and sperm has been observed in the normal control group and the test group by implementing Periodic acid Schiff dyeing after extraction. 24 hours after irradiation, a gradual decrease in sperm count and testicular cells qualitatively and quantitatively that were identified as significant.

A Fast and Robust Algorithm for Fighting Behavior Detection Based on Motion Vectors

  • Xie, Jianbin;Liu, Tong;Yan, Wei;Li, Peiqin;Zhuang, Zhaowen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.11
    • /
    • pp.2191-2203
    • /
    • 2011
  • In this paper, we propose a fast and robust algorithm for fighting behavior detection based on Motion Vectors (MV), in order to solve the problem of low speed and weak robustness in traditional fighting behavior detection. Firstly, we analyze the characteristics of fighting scenes and activities, and then use motion estimation algorithm based on block-matching to calculate MV of motion regions. Secondly, we extract features from magnitudes and directions of MV, and normalize these features by using Joint Gaussian Membership Function, and then fuse these features by using weighted arithmetic average method. Finally, we present the conception of Average Maximum Violence Index (AMVI) to judge the fighting behavior in surveillance scenes. Experiments show that the new algorithm achieves high speed and strong robustness for fighting behavior detection in surveillance scenes.

The Effects of the CT Voltages on the Dose Calculated by a Commercial RTP System (CT 관전압이 상용 전산화치료계획장치의 선량계산에 미치는 영향)

  • 강세권;조병철;박희철;배훈식
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • The relationship between the dose calculated with a radiotherapy treatment planning system (RTPS) and CT number verses the relative electron density curve was investigated for various CT voltages and beam qualifies. We obtained the relationship between the CT numbers and electron densities of the tissue equivalent materials for various CT voltages and beam qualifies. At lower CT voltages, the higher density materials, like cortical bone, showed larger CT numbers and the soft tissues showed no variations. We peformed a phantom study in a RTPS, where a phantom consisted of lung and bone legions in water. We calculated the dose received behind the lung and bone regions for 6 MV photon beams, in which the regions below the lung, water and bone received higher doses in this listed order. The result was the same for 10 MV photon beams. For the clinical application, the doses were calculated for the lung and pelvis. No difference was observed when using different electron density conversion tables with various CT voltages from a same CT. A relative dose difference of 1.5% was obtained when the CT machine for the density conversion table was different from that for the CT image for planning.

  • PDF

3-D Graphics Simulators : SOFTGRA and RACA (3차원 그래픽스 시뮬레이터 : SOFTGRA와 RACA)

  • Eo, Kil-Su;Choi, Hun-Kyu;Kyung, Chong-Min
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1528-1531
    • /
    • 1987
  • Two graphics simulators, SOFTGRA and RACA, have been developed. The SOFTGRA has been implemented by the scan line algorithm using 2 shading models with multi-light sources. The RACA is a ray casting simulator which produces shadowed images with realism. Above two simulators run on Sun micro system and MV10000 and produce image data which are transfered into IBM AT with Metheus' Omega graphics board and drawn there.

  • PDF

Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging

  • Ji Young Choi;Jihye Yun;Subin Heo;Dong Wook Kim;Sang Hyun Choi;Jiyoung Yoon;Kyuwon Kim;Kee Wook Jung;Seung-Jae Myung
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1093-1101
    • /
    • 2023
  • Objective: Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility. Materials and Methods: A total of 174 participants (28.5 ± 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score's correlation (Spearman's ρ) with the reference standard and performance (area under the receiver operating characteristics curve [AUROC], sensitivity, and specificity) for diagnosing adynamic small bowel (MV of 1) were evaluated. Results: For the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean ± standard deviation values were 0.019 ± 0.003, 0.027 ± 0.010, 0.033 ± 0.008, 0.032 ± 0.009, and 0.043 ± 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (ρ = 0.531, P < 0.001). The AUROC value for diagnosing a MV of 1 (i.e., adynamic small bowel) was 0.953 (95% confidence interval, 0.923-0.984). Moreover, the optimal cutoff for the quantitative motility score was 0.024, with a sensitivity of 100% (15/15) and specificity of 89.9% (143/159). Conclusion: The quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

  • Jin, Hosang;Jesseph, Fredrick B.;Ahmad, Salahuddin
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the Varian Eclipse treatment planning system (TPS). An isocentrically mounted Sun Nuclear MapCHECK 2 diode array with 5 cm water-equivalent buildup was also used for the VMAT QAs and the measurements were compared to a composite dose plane from the Eclipse TPS. A ${\gamma}$ test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison at 1%/1 mm (dose difference/distance-to-agreement), 2%/2 mm, and 3%/3 mm criteria for both QA methods. The two-tailed paired Student's t-test was employed to analyze the statistical significance at 95% confidence level. The average ${\gamma}$ passing rates were greater than 95% at 3%/3 mm using both methods for all four energies. The differences in the average passing rates between the two methods were within 1.7% and 1.6% of each other when analyzed at 2%/2 mm and 3%/3 mm, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1 mm; the difference was lower for 8 MV and 10 MV. However, the differences were not statistically significant for all criteria and energies (p-values >0.05). The EPID-based QA showed large off-axis over-response and dependence of ${\gamma}$ passing rate on energy, while the MapCHECK 2 was susceptible to the MLC tongue-and-groove effect. The two fluence-based QA techniques can be an alternative tool of VMAT QA to each other, if the limitations of each QA method (mechanical sag, detector response, and detector alignment) are carefully considered.