• Title/Summary/Keyword: MS0

Search Result 4,759, Processing Time 0.036 seconds

A Study on the Characteristics of Nutrient Intake in Metabolic Syndrome Subjects (대사증후군 대상자의 영양소 섭취 특성에 관한 연구)

  • Yoo, Hyun-Jung;Kim, Yang-Ha
    • Journal of Nutrition and Health
    • /
    • v.41 no.6
    • /
    • pp.510-517
    • /
    • 2008
  • This study was conducted to investigate the prevalence of metabolic syndrome(MS) and characteristics of nutrient intake in MS subjects by gender and age. The subjects were 957(447 men and 510 women) who visited medical center for regular medical check-up. The diagnosis of MS subjects was adapted from NCEP-ATPIII with blood glucose, cholesterol, triglycerides, and blood pressure and Aisa-Pacific definition with waist-circumference. Anthropometric and biochemical measurements were practiced, then the nutrient intake analysis was assessed through the 24-hour recall method. The MS prevalence of all subjects was 10.3% in average -17% in men and 4.5% in women, respectively. The energy intake in MS group was 2,047.1 kcal and 1,699.5 kcal for normal group, showing significantly higher in MS compared to normal subjects. For intakes of animal fat, cholesterol, and sodium, MS group were significantly higher than normal group. In respect of gender, men subjects of MS group showed significantly higher nutrient intakes than normal group for energy, fat, and cholesterol. Women subjects of MS group showed higher intakes for energy, carbohydrate, and protein. For 30s, MS group showed higher intakes of energy, animal fat, and cholesterol than normal group. Fat and cholesterol for 40s and energy, carbohydrate, vegetable fat for 50s, MS group showed significantly higher intakes than normal group. In summary, MS group showed higher intakes of energy, animal fat, cholesterol, and sodium than normal group.

Determination of 8-iso-PGF as Oxidative Stress Marker in Human Urine by High Performance Liquid Chromatography with Tandem Mass Spectrometry (LC/MS/MS를 이용한 산화성 스트레스 지표로써 소변 중 8-iso-PGF 분석)

  • Kho, Young-Lim;Lee, Eun-Hee;Chae, Hong-Jae;Choi, Kyung-Ho;Paik, Do-Myung
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.1
    • /
    • pp.44-51
    • /
    • 2010
  • This study aimed to develop analytical method for 8-isoprostanes as biomarkers for oxidative stress with LC/MS/MS technique and to apply the method for human urine samples. Analyzed compounds for urinary oxidative stress markers were 7 stereo-isomers of prostaglandins and the internal standard (iso-$PGF_{2{\alpha}}-d_4$) was used to adjust the recovery rate. The method for determining urinary iso-$PGF_{2{\alpha}}$ consisted of solid phase extraction and LC/MS/MS detection. Separation of isomers of prostaglandins completed by porous graphitic carbon column and buffer solution. Detection limits for urinary markers of oxidative stress, iso-$PGF_{2{\alpha}}$ with LC/MS/MS were 0.01 ng/ml by S/N ratio 3 and 0.028 ng/ml by calculated as to FDA method. The recovery (92.8~101.9%) and precision (8.8~20.7%) of analysis were feasible for detecting iso-$PGF_{2{\alpha}}$ in real human urine samples. We detected 4 isomers of prostaglandins in human urine samples. Mean (standard deviation) of urinary iso-$PGF_{2{\alpha}}$ concentration were 0.231 (0.117) ng/mg creatinine for smoking group and 0.154 (0.082) ng/mg creatinine for non-smoking group.

Evaluation of Pre-treatment Stages for Microcystins Analysis using LC/MS/MS (LC/MS/MS 분석을 위한 microcystins 전처리 단계별 효율성 연구)

  • Kim, Hwa-Bin;Park, Hae-Kyung;Moon, Jeong-Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.720-726
    • /
    • 2009
  • We investigated the most effective pre-treatment processes and LC/MS/MS condition for microcystins analysis. With a step-by-step pre-treatment, efficiencies of several established methods were compared. At the level of cell burst, sonication method was found to be the most efficient. As a mycrocystins first extraction solvent, 5% acetic acid showed the highest efficiency. An isolation and recovery rate of mycrocystins of ODS Sep-Pak $C_{18}$ cartridge was higher than HLB SPE cartridge. As a final elution solvent from cartridge, 100% MeOH had a better efficiency than others. Using a LC/MS/MS, effective analytical methods were established. C18 reverse column was used and gradient elution was performed with using acetonitrile, 0.1% formic acid as a mobile phase. We analysed to 0.8 mL/min flow rate fit to the $5{\mu}m$ particle size column and $55^{\circ}C$ housing temperature. The validity of established analytical method was evaluated that MDL as average $0.050{\pm}0.014{\mu}g/L$ and LOQ as average $0.160{\pm}0.045{\mu}g/L$ had a good sensitivity over 40 magnification rather than $2{\mu}g/L$ detection limit of HPLC.

The analysis of pharmaceuticals in drinking water by HPLC/ESI-MS/MS (HPLC/ESI-MS/MS에 의한 먹는물(정수) 중 의약물질의 분석)

  • Park, Mi-Sun;Kim, Byung-Joo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.457-464
    • /
    • 2010
  • The analytical method of four pharmaceuticals (virginiamycin, erythromycin, tylosin and cimetidine) in drinking water was developed. Effective simultaneous sample clean-up and extraction by solid-phase extraction (SPE) using HLB cartridge prior to LC/ESI-MS/MS analysis were performed. A linear correlation observed in the calibration curves for drinking water in the range of 0.01~2.0 ng/mL showed above $r^2$=0.995. Absolute recovery was in the range of 64.7~118.1% (except cimetidine (37.7~48.1%)). Limit of detection (LOD) and limit of quantitation (LOQ) in spiked drinking water matrix were in the range of 1.6~74.8 pg/mL and 5.5~249.7 pg/mL, respectively. The established method can be used to determine low pg/mL levels of pharmaceuticals in the drinking water.

Determination of 105 pesticide residues by GC/MS/MS (GC/MS/MS를 이용한 105종의 잔류농약 분석에 관한 연구)

  • Kim, W.S.;Do, J.A.;Lee, H.J.;Lee, J.Y.;Yang, S.J.;Lee, S.H.
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.395-404
    • /
    • 2010
  • A multi-residual method using gas chromatography coupled with mass spectrometry (GC/MS/ MS) was developed for the analysis of 105 pesticides. This method was tested on lemons, beans and other vegetables. The pretreatment of these pesticides was performed by liquid-liquid partition followed by cleanup with solid phase extraction cartridge (SPE Florisil), after acetonitrile extraction from matrices and sodium chloride (15 g) addition. The recovery ranged from 71.1% to 126.0% except for azinphosmethyl, famoxadone, fenamidone, flufenoxuron and triadimefon in lemons and from 72.5% to 124.5% in bean. In lemon, the limit of detection (LOD) and limit of quantification (LOQ) were 0.001~150 ng/ mL and 0.004~500 ng/mL, respectively.

Callus induction and plant regeneration from in vitro cultured petiole of 3 Gerbera cultivars. (거베라 기내 엽병조직으로부터 Callus 유도 및 식물체 재분화)

  • 정용모;나애실;고은경;송혜정;김정부;권오창
    • Journal of Life Science
    • /
    • v.14 no.5
    • /
    • pp.855-858
    • /
    • 2004
  • The experiment was conducted to investigate optimal condition for callus induction and plant regeneration for transformation system of gerbera. Callus induction was more effective in 'white day' then other two cultivar 'Songsongee' and 'Love Song' The optimized plant growth regulators concentration on callus induction, was MS basal medium with NAA 0.1 mg/L+ TDZ 0.5 mg/L. The optimized plant growth regulators concentration on plant regeneration, which was used MS basal medium was IAA 1.0 mg/L + BA 1.0 mg/L + Zeatin 0.1 mg/L. The optimized petiole age for more effective plant regeneration was 32 days petiole after in vitro subculture and MS basal medium strength was 1/2 MS strength.

An 8b 220 MS/s 0.25 um CMOS Pipeline ADC with On-Chip RC-Filter Based Voltage References (온-칩 RC 필터 기반의 기준전압을 사용하는 8b 220 MS/s 0.25 um CMOS 파이프라인 A/D 변환기)

  • 이명진;배현희;배우진;조영재;이승훈;김영록
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.69-75
    • /
    • 2004
  • This work proposes an 8b 220 MS/s 230 mW 3-stage pipeline CMOS ADC with on-chip filers for temperature- and power- insensitive voltage references. The proposed RC low-pass filters improve switching noise performance and reduce reference settling time at heavy R & C loads without conventional off-chip large bypass capacitors. The prototype ABC fabricated in a 0.25 um CMOS occupies the active die area of 2.25 $\textrm{mm}^2$ and shows the measured DNL and INL of maximum 0.43 LSB and 0.82 LSB, respectively. The ADC maintains the SNDR of 43 dB and 41 dB up to the 110 MHz input at 200 MS/s and 220 MS/s, respectively, while the SNDR at the 500 MHz input is degraded as much as only 3 dB than the SNDR at the 110 MHz input.

Anomalous somatic embryos formation and plant regeneration from the cultures of immature embryos of Camellia japonica L. (동백나무 미숙배 배양으로부터 비정상 체세포배 형성과 식물체 재생)

  • Choi, Jong-Hye;Kwon, Suk-Yoon;Choi, Pil-Son
    • Journal of Plant Biotechnology
    • /
    • v.38 no.4
    • /
    • pp.258-262
    • /
    • 2011
  • Embryogenic callus was induced from the cultures of immature embryos of Camellia japonica L. on Murashige & Skoog's (MS) solid medium supplemented with 1 mg/L 2,4-dichlorophenoxy acetic acid (2,4-D), and then the embryogenic callus was proliferated on same medium for 4 weeks over. The embryogenic callus was sub-cultured on MS basal medium without 2,4-D to produce coyledonary stage of somatic embryo. The frequency (%) of somatic embryogenesis was 25.1%, and the majority of somatic embryos formed had a abnormal morphology with cupshaped cotyledon (48.3%), one cotyledon (12.6%), three cotyledons (9.4%), four cotyledons (1.9%), whereas was only normal morphology with two cotyledon (27.5%). When the somatic embryos with normal or abnormal cotyledons transfer to MS basal medium or $\frac{1}{2}$ MS medium with/or without plant growth regulators ($GA_3$, IBA) for regeneration, the frequency (%) of two-cotyledon embryos regenerated into plantlets was higher 11.1% than one cotyledon (0.0~8.3 %), three cotyledons (0.0~5.8%), four cotyledons (0.0%), cup-shaped (0.3~4.2%). These results demonstrated that the anomalous cotyledons of somatic embryos could caused to decrease the rate of plant regeneration.

Micropropagation from Corm Apical Meristems Culture of Freesia refrecta Hybrida (정단 분열 조직배양에 의한 후리지아의 미세번식)

  • 고정애;김명준;김현순;이진재;김영숙
    • Korean Journal of Plant Resources
    • /
    • v.16 no.1
    • /
    • pp.34-39
    • /
    • 2003
  • Corm apical meristem cultures of thirteen glasshouse freesia cultivars were tested to investigate the possibility of micropropagation using MS basal medium supplemented with 2,4-D, NAA(0.1, 0.5, 1.0mg/L, respectively) and BA (0.5∼2.0mg/L). The majority of the tested cultivars could be induced callus and shoot buds in all culture condition. The combinations of NAA and BA appeared superior to that of 2,4-D and BA depending on cultivars for callus induction and shoot formation. Among the cultivars, 'Golden Yellow' showed the highest regeneration capacity on MS media with 0.5mg/L NAA and 1.0 mg/L BA. The highest percentage of regeneration and the greatest number of shoot from calli were obtained through successive subculture on MS medium supplimented with 0.5mg/L BA. In that condition, more than 60 % shoot regeneration and average of 25.1 shoots per explant was achieved. Transformed shoots on half-strength MS medium without plant growth regulators rooted easily.

Development of LC-MS/MS analytical methods for metalaxyl in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai (LC-MS/MS를 이용한 생약 백출 및 우슬 중 Metalaxyl 잔류분석법 개발)

  • Yun, Myung-Sub;Yang, Seung-Hyun;Choi, Hoon
    • Journal of Applied Biological Chemistry
    • /
    • v.65 no.1
    • /
    • pp.17-21
    • /
    • 2022
  • A new rapid and simple method for metalaxyl in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai has been developed and validated. This study was conducted to develop a method for analyzing metalaxyl by a method based on QuEChERS using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Samples were extracted with acetonitrile and purified using amino-propyl (NH2) Solid Phase Extraction cartridge. The method limit of quantitation (MLOQ) was 0.01 mg/kg. The linearity of matrix-matched calibration curve (r2) was ≥0.99 at the calibration range of 0.001-0.05 mg/kg. For recovery test, Atractylodes macrocephala Koidzumi or Achyranthes japonica Nakai was treated with standard solutions at MLOQ and 10MLOQ levels. Recovery rates were in the range of 88.1-109.1% with <5.5% coefficient of variation. This established analytical method was fully validated. Based on these results, it can contribute to improving the safety of residual pesticides in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai.