• Title/Summary/Keyword: MRI magnet

Search Result 84, Processing Time 0.023 seconds

Fabrication of Prototype Persistent Current Switch System Using by BSCCO-2223 Tape (BSCCO-2223 선재를 이용한 Prototype 영구전류스위치 시스템의 제작)

  • 강형구;김정호;이응로;안민철;김호민;윤용수;오상수;주진호;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.72-75
    • /
    • 2001
  • The persistent current mode operation of HTS coils is one of the key technologies required for very high-field MRI magnets composed of LTS and HTS coils. But to date, the fabrication of persistent current mode system using HTS is not investigated well. In this paper, we fabricated the magnet and PCS using by BSCCO-2223 tape and jointed them with solder. The current decay behavior of the circuit was measured in liquid nitrogen by monitoring the magnetic field in the centre of magnet with a Hall sensor. To enhance the characteristic of persistent current mode system, superconducting joint method should be investigated.

  • PDF

The Study on the Characteristics and Design Method of High-Tc Superconducting Persistent Current Switch (고온초전도 영구전류스위치의 특성 및 설계에 관한 연구)

  • 박상건;강형구;배덕권;윤용수;김태중;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.216-219
    • /
    • 2003
  • Persistent Current Switch (PCS) is used in many superconducting magnet system. To apply the high-Tc superconductor in superconducting machine such as motor, generator, MAGLEV, MRI and NMR, the study on the persistent current mode should be performed. Because persistent current mode provide best stability and homogeneous characteristics to the superconducting machine. To stabilize the superconductor system, it is important to estimate the length of PCS. If the proper length of PCS is too short, it cause serious injury to system in fault state. So we calculated the optimal length of PCS in this paper.

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

Development of a magnetic field calculation program for air-core solenoids which can control the precision of a magnetic field

  • Huang, Li;Lee, Sangjin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.53-56
    • /
    • 2014
  • A numerical method of magnetic field calculation for the air-core solenoid is presented in this paper. In application of the Biot-Savart law, the magnetic field induced from the source current can be obtained by a double integration ormula. The numerical method named composite Simpson's rule for the integration is applied to the program and the adaptive quadrature method is used to adjust the step size in the calculation according to the precision we need. When the target point is in the solenoid and the intergrand's denominator may be zeroin the process of calculation, the method sill can provide an appropriate result. We have developed a program which calculates the magnetic field with at least 1ppm precision and named it as rzBI() to implement this method. The method has been used in the design of an MRI magnet, and the result show it is very flexible and convenient.

Study on the adiabatic method and condition of persist current switch for MRI (MRI용 영구전류스위치의 열적 트리거 제어를 위한 단열 방법 및 조건에 관한 연구)

  • Ko, Rock-Kil;Bae, Joon-Han;Sim, Ki-Deok;Jin, Hong-Beam;Kwon, Young-Kil;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.949-951
    • /
    • 2000
  • In order to design thermally trigger controlled persistent current switch(PCS) for MRI magnet system, it is very important to know informations of applied adiabatic method and condition to get designed resistance and characteristics. Adiabatic part of PCS is consist of cotton-gummed tape and cryogenic stycast. This adiabatic method has the advantage of continuously winding superconducting and adiabatic part of PCS and reducing the time of manufacture. We experimentally derived averaged thermal conductivity on the assumption that shape of adiabatic part of PCS is that of pipe. In result, averaged thermal conductivity is about 0.29 W/m K and designed value is very satisfied with actual experimental data.

  • PDF

Design of Body RF Coil with Multiple Strips for Open MRI System by Pseudo Electric Dipole Radiation

  • 김경락;류승학;류연철;양형진;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.76-76
    • /
    • 2002
  • Purpose: The purpose of this study is to optimize the configuration of body RF coil composed of 4 planar subcoils for low field open MRI. Method: Our low field RE coil is composed of 4 subcoils assumed to be located at both the bottom and top sides of permanent magnet. Each subcoils has 3 main strips. The coil system has mirror inversion symmetry. First, the currents on the strips are obtained by inductance calculation and circuit analysis, Second, all the strips are divided into line strip elements across the strips, the self Inductances of line strip elements and the mutual inductances among the line strip elements are calculated, and current distributions of strip are obtained by circuit analysis, where each strip is considered as parallel combination of line strip elements. Finally all the line strip elements are segmented, magnetic field has been calculated by pseudo electric dipole radiation method, where the current elements are regarded as pseudo electric dipole radiation sources. We have performed above procedures for various configurations of RE coil. The field homogeneity is calculated in the 25 cm DSV.

  • PDF

Fabrication and test of heater triggered persistent current switch using coated conductor tapes (Coated conductor를 이용한 히터트리거 방식의 영구전류 스위치의 제작과 실험)

  • Kim, Young-Jae;Yang, Seong-Eun;Park, Dong-Keun;Ahn, Min-Cheol;Yoon, Yong-Soo;Ko, Tae-Huk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2039-2040
    • /
    • 2006
  • Persistent current switch (PCS) system in NMR, MRI, MAGLEV and SMES has many advantages, such as uniformity and durability of magnetic field and reducing a thermal loss, which enable many superconducting application to operate effectively. This paper deals with fabrication and test of heater trigger persistent current switch using coated conductor (CC) which has high n-index, critical current independency from external magnetic field and adaptable selectivity of stabilizer. PCS system consists of magnet power supply for energizing current to a magnet, heater, switch and magnet using coated conductor tape. Finite element method (FEM) is used to simulate thermal quench (switching) characteristic and design heater trigger. With FEM simulation, optimal length of heater is calculated by temperature and time analysis. Fabrication of PCS system and test of heater trigger characteristic were performed and compared with simulation result. This paper would be the foundation of researches of superconducting switching application.

  • PDF

Estimation of the critical current of race-track HTS magnet considering angular dependency

  • Lee, Kyubong;Sim, Kideok;Lee, Changyoung;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.47-50
    • /
    • 2015
  • The high temperature superconducting (HTS) magnet has been developed for the high magnetic field applications such as NMR, MRI and other industrial machinery. In designing process of these HTS magnets, the accurate estimation on the critical current (Ic) is essential to predict and secure the electromagnetic performance. The critical current of 2G HTS tape has anisotropic Ic degradation characteristics with the application of magnetic field - angular dependency of critical current. It is known that the perpendicular magnetic field to the face of HTS tape makes dominant degradation on the critical current for conventional 2G HTS tape. However, recently developed 2G HTS tape has more complex characteristics due to the artificial pinning center. Therefore, the method for Ic estimation reflecting such characteristics of 2G HTS tape needs to be devised. The method considering the angular dependency is introduced in this paper. And the result of newly devised method is compared with that of previous method.

Pumping-up Current Characteristics of Linear Type Magnetic Flux Pump

  • Chung, Yoondo;Muta, Itsuya;Hoshino, Tsutomu;Nakamura, Taketsune;Ko, Taekuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.29-34
    • /
    • 2004
  • The linear type flux pump aims to compensate a little bit decremental persistent current of the HTS magnet in NMR and MRI spectrometers. The flux pump mainly consists of DC bias coil, 3-phase AC coil and Nb foil. The persistent current in closed superconductive circuit can be easily adjusted by the 3-phase AC current, its frequency and the DC bias current. In the experiment, it has been investigated that the flux pump can effectively charge the current in the load coil of 543 mH for various frequencies in 18 minutes under the DC bias of 10 A and the AC of 5 $A_{rms}$. The maximum magnitudes of pumping current and load magnet voltage are 0.72 A/min and 20 ㎷, respectively. Based on simulation results by the FEM are proved to nearly agree with experimental ones.

Design, fabrication and test of inside notched superconducting coil (내노치형 초전도 솔레노이드 마그네트의 설계.제작 및 평가)

  • Nah, Wan-Soo;Jin, Hong-Beom;Oh, Bong-Hwan;Kwon, Young-Kil;Oh, Sang-Soo;Cho, Jeon-Wook;Ha, Dong-Woo;Lee, Eon-Yong;Ryu, Kang-Sig
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.63-65
    • /
    • 1994
  • In this paper, the design, fabrication and test of inside notched superconducting coil are described. The inside notched coil is one of the basic configurations, producing homogeneous magnetic field. This magnet is a primitive version of MRI or NMR magnet in Korea Electromagnetic Research Institute. To test the magnetic field distribution inside the magnet, a X-Z scanner was made and the homogeneity was about $1.8{\times}10^{-3}$in 5 cm dsv (Diameter of Spherical Volume).

  • PDF