• Title/Summary/Keyword: MR Spectrum

Search Result 53, Processing Time 0.022 seconds

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Quantitative Comparison of 1H-MRS Spectra Depending on the Paramagnetic Gadolinium Contrast Agent(GBCA) Injection (가돌리늄 조영제 주입에 따른 1H-MRS spectrum의 정량적 비교)

  • Choi, Kwan-Woo;Son, Soon-Yong;Yoo, Beong-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.589-595
    • /
    • 2017
  • This study evaluated the effect of gadolinium contrast agents on the spectrum of metabolites during $^1H-MRS$ of brain and to investigate whether the contrast agents injected before MR spectroscopy significantly affect the estimated peaks of MRS. From January to May 2017, brain MR spectroscopy was performed on 30 patients to compare the spectrum before and after contrast injection of the brain white matter tissue. As a result, the spectrum of metabolites decreased after the paramagnetic contrast agents injected. However, it was not statistically significant which indicated that the use of contrast agent did not meaningfully affect the spectrum of metabolites. In conclusion, the use of the paramagnetic contrast before the acquisition of the spectroscopy may aid voxel positioning especially when it is difficult to determine the exact location of the lesion or the contrast is low.

Response and control of jacket structure with magneto-rheological damper at multiple locations/combinations

  • Syed, Khaja A.A.;Kumar, Deepak
    • Ocean Systems Engineering
    • /
    • v.8 no.2
    • /
    • pp.201-221
    • /
    • 2018
  • In this paper a comprehensive study for the structural control of Jacket platform with Magneto-Rheological (MR) damper is presented. The control is implemented as a closed loop feedback of the applied voltage in the MR Damper using fuzzy logic. Nine cases of combinations with MR damper are presented to complete the work. The selection of the MR damper (RD 1005-3) is based on the operating parameters (i.e., the range of frequency and displacement). Bingham model is used to obtain the control forces. The damping co-efficient of the model is obtained using empirical relationship between the voltage in the MR damper and input velocity from the structural members. The force acting on the structure is obtained from Morison equation using P-M spectrum. The results show that the reliable control was obtained when there was a continuous connection of multiple MR dampers with the lower levels of the structure. Independent MR dampers at different levels provided control within a range, while the MR dampers placed at alternate positions gave very high control.

Comparison with 1.5Tesla and 3.0Tesla of Acoustic Noise Spectrum of DWI MR Pulse Sequence (1.5Tesla and 3.0Tesla에서 관류 MR의 소리 스펙트럼 분석)

  • Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.491-496
    • /
    • 2018
  • The purpose of this study is to analyze the noise spectra in DWI (diffusion-weighted imaging) pulse sequences of 1.5 Tesla and 3.0 Tesla MRI, The ACR (American College of Radiology) phantom and noise spectrum were analyzed by FFT (fast Fourier transform) and TFFT (temporal frequency analysis) using WavePad sound editor version 8.13 (NCH software, Greenwood Village, CO, USA). Noise spectra, FFT and TFFT were analyzed for laboratory 1.5Tesla and 3.0Tesla DWI MR pulse sequences. The noise threshold of the frequency amplitude in the FFT and TFFT at 3.0Tesla compared to 1.5Tesla was between 1.5Tesla and -6 dB, and between 3.0Tesla and 0 dB, the DWI pulse sequence for the patient's noise reduction was appropriately MR examination needs to be applied.

Maxima Response Spectrum for each Mechnical Vibration and its Application (기계적 진동에 대한 MRS 및 MRS의 응용)

  • 김재하;우호길
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.234-245
    • /
    • 2001
  • This paper considers the Maximum Pesponse Spectrum for the random vibration, sinusoidal vibration, linear sweep vibration. The random vibration quality levels and the sinusoidal vibration quality level are compared using MRS. And the severity between the vibration test specification and real environments using Maximum Response Spectrum are also compared using it.

  • PDF

Use of Various Treatment Modalities for Autism Spectrum Disorder and Mental Retardation (정신지체 및 자폐스펙트럼장애에서 다양한 치료방법의 사용실태)

  • Kim, Kyung Min;Choi, In Chul;Lee, Seok Bum;Lee, Kyung Kyu;Paik, Ki Chung;Lee, Jeong Yeob;Lim, Myung Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.25 no.2
    • /
    • pp.73-81
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate the use of various treatment modalities including pharmacotherapy, educational-behavioral therapy, and complementary alternative treatment for children with mental retardation (MR) or autism spectrum disorder (ASD) in Korea. Methods : The sample consisted of 50 parents who have children with MR (N=28) or ASD (N=22) : 38 boys, 12 girls ; mean age 14.06 (4.14) years old. A questionnaire was composed of the experienced modality, duration, cost, satisfaction, etc. Results : According to the results, 56.0%, 100.0%, and 36.0% of children with MR or ASD have experienced pharmacological treatment, educational-behavioral therapy and complementary alternative medicine (CAM), respectively. Children who experienced educational-behavioral therapy and CAM experienced 3.52 kinds of education-behavioral therapy and 2.78 kinds of CAM, respectively. Monthly cost of pharmacological treatment was lowest among three modality categories. Regarding treatment satisfaction by parental report, the lowest score was recorded for CAM. Conclusion : Parents who have a child with MR or ASD are trying many treatment modalities and feeling the burden of their treatment.

Absorbance Spectrum for Mesodinium rubrum MR-MAL01, a marine photosynthetic ciliate, fed on Photo-adapted Cryptophyte (광적응된 은편모조류를 섭식한 해양 광합성 섬모류 Mesodinium rubrum MR-MAL01의 흡광스펙트럼)

  • 김형섭;명금옥;조수근;이원호
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.1
    • /
    • pp.29-34
    • /
    • 2003
  • Recent reports on the phagotrophic feeding of M. rubrum are based on cultivation experiments with novel isolates of this ciliate species from Gomso Bay, Korea. Photo-adapted cryptophyte(CR-MAL01) cultures at high light of 100 $\mu$mol photons m$^{-2}$ s$^{-1}$ (HL) and low light of 10 $\mu$mol photons m$^{-2}$ s$^{-1}$ (LL) were fed to M. rubrum (MR-MAL01) cultures under HL and LL conditions, respectively. Absorbance spectrum by LL M. rubrum showed the same peak at wavelengths around 542nm as that by LL cryptophyte prey, which was not showed in HL M. rubrum. This result supports the implication that light utilization and absorption pattern of M. rubrum population must depend on the status of photo-adaptation of the co-existing population of prey cryptophyte. Consequences of the present research results were discussed in relation to the function of the prey cryptophyte and phagotrophic M. rubrum in marine microbial ecosystem.

Development of PC Based Signal Postprocessing System in MR Spectroscopy: Normal Brain Spectrum in 1.5T MR Spectroscopy (PC를 이용한 자기공명분광 신호처리분석 시스템 개발: 1.5T MR Spectroscopy에서의 정상인 뇌 분광 신호)

  • 백문영;강원석;이현용;신운재;은충기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2000
  • Purpose : The aim of this study is to develope the Magnetic Resonance Spectroscopy(MRS) data processing S/W which plays an important role as a diagnostic tool in clinical field. Materials and methods : Post-processing software of MRS based on graphical user interface(GUI) under windows operating system of personal computer(PC) was developed using MATLAB(Mathwork, U.S.A.). This tool contains many functions to increase the quality of spectrum data such as DC correction, zero filling, line broadening, Gauss-Lorentzian filtering, phase correction, etc. And we obtained the normal human brain $^1H$ MRS data from parietal white matter, basal ganglia and occipital grey matter region using 1.5T Gyroscan ACS-NT R6 (philips, Amsterdam, Netherland) MRS package. The analysis of the MRS peaks were performed by obtaining the ratio of peak area. Results : The peak ratios of NAA/Cr, Cho/Cr, MI/Cr for the different MRS machines have a little different values. But these peak ratios were not significantly different between different echo time MRS peak ratios in the same machine (p<0.05). Conclusion : MRS post-processing S/W based on GUI using PC was developed and applied to the analysis of normal human brain $^1H$ MRS. This independent MRS processing job increases the performance and throughput of patient scan of main console. Finally, we suggest that the database for normal in-yivo human MRS data should be obtained before clinical applications.

  • PDF

Analysis of Multicarrier DS/DPSK Systems with Single Tone Interference Rejection (단일톤 간섭제거를 위한 다단반송파 DS/DPSK 시스템의 성능분석)

  • 엄종선;김동인
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.4
    • /
    • pp.761-770
    • /
    • 1997
  • Narrowband signals can be treated like a single tone interference at the receiver which demodulates wideband signals spectrum overlaid at the same frequency band. In this paper, the single tone interference is effectively suppressed by the use of a multicarrier DPSK direct-sequence(DS) spread spectrum(SS) with maximal-ratio(MR) combining instead of notch filter, which is hard to implement. A noncoherent DPSK system is considered because it is more realizable and does not require any complicate phase tracking, compared with a single carrier system subject to a constraint system bandwidth, and their performance comparisons are validated through simulation. We also propose a suboptimal-ratio(SR) combining which yields uniform and tight low bound on the performance of the MR combining, and then system parameters re optimized by theoretically evaluating the low bound, since an exact analysis appears intractable.

  • PDF

The Analysis of Brain Tumor's Grades Using Magnetic Resonance Spectroscopy (대뇌 종양에서 자기공명 분광법 적용 결과의 분석 연구)

  • Yun, Sang-Jun;Lim, Jong-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.355-365
    • /
    • 2008
  • Purpose : This study isto determine the grade of brain tumor and compare the characteristics in each grade using in MRS (MR Spectroscopy). Method : STEAM (Stimulated Echo Acquisition Method) and protocol of PRESS (Point Resolved Spectroscopy) were used in the levels of tumor grade. We classified the pattern of tumor and analysis of the spectrum signals quantitatively from voxel in the brain tumor grade. In accordance with the result, we calculated the accuracy of biochemical. Result : In high-grade tumor, the NAA/Cr showed the signal reduction of 29.4% and 53.9%. However Cho/Cr increased 570% and 711%. However, in low-grade tumor, NAA/Cr downed to 42.6% and 58.1%. Cho/Cr increased to 188% and 195%. Conclusion : The study suggests that the comparative analysis of signals from MR spectroscopy could be useful to evaluate the grade of tumor and find out the characteristics of it. By extension, MR spectroscopy can be used for research with other organs in the human.

  • PDF