• 제목/요약/키워드: MIR

검색결과 304건 처리시간 0.026초

SPACE OF HOMEOMORPHISMS UNDER REGULAR TOPOLOGY

  • Mir Aaliya;Sanjay Mishra
    • 대한수학회논문집
    • /
    • 제38권4호
    • /
    • pp.1299-1307
    • /
    • 2023
  • In this paper, we attempt to study several topological properties for the function space H(X), space of self-homeomorphisms on a metric space endowed with the regular topology. We investigate its metrizability and countability and prove their coincidence at X compact. Furthermore, we prove that the space H(X) endowed with the regular topology is a topological group when X is a metric, almost P-space. Moreover, we prove that the homeomorphism spaces of increasing and decreasing functions on ℝ under regular topology are open subspaces of H(ℝ) and are homeomorphic.

GENERALIZED DERIVATIONS IN RING WITH INVOLUTION INVOLVING SYMMETRIC AND SKEW SYMMETRIC ELEMENTS

  • Souad Dakir;Hajar El Mir;Abdellah Mamouni
    • 대한수학회논문집
    • /
    • 제39권1호
    • /
    • pp.1-10
    • /
    • 2024
  • In this paper we will demonstrate some results on a prime ring with involution by introducing two generalized derivations acting on symmetric and skew symmetric elements. This approach allows us to generalize some well known results. Furthermore, we provide examples to show that various restrictions imposed in the hypotheses of our theorems are not superfluous.

CHANDRA OBSERVATIONS OF THE AKARI NEP DEEP FIELD

  • Miyaji, T.;Krumpe, M.;Brunner, H.;Ishigaki, T.;Hanami, H.;Markowitz, A.;Takagi, T.;Goto, T.;Malkan, M.A.;Matsuhara, H.;Pearson, C.;Ueda, Y.;Wada, T.
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.235-237
    • /
    • 2017
  • The AKARI NEP Deep Field Survey is an international multiwavelength survey over $0.4deg^2$ of the sky. This is the deepest survey made by the InfraRed Camera (IRC) of the infrared astronomical satellite AKARI with 9 filters continuously covering the $2-25{\mu}m$ range, including three filters in the Spitzer gap between the IRAC and MIPS coverages. This enabled us to make sensitive MIR detection of AGN candidates at z~ 1, based on hot dust emission in the AGN torus. It is also efficient in detecting highly obscured Compton-thick AGN population. In this article, we report the first results of X-ray observations on this field. The field was covered by 15 overlapping Chandra ACIS-I observations with a total exposure of ~300 ks, detecting ${\approx}450$ X-ray sources. We utilize rest-frame stacking analysis of the MIR AGN candidates that are not detected individually. Our preliminary analysis shows a marginal detection of the rest-frame stacked Fe $k{\alpha}$ line from our strong Compton-thick candidates.

Genetic diversity, structure analysis and relationship in soybean mutants as revealed by TRAP marker

  • Kim, Dong-Gun;Lyu, Jae-Il;Lee, Min-Kyu;Kim, Jung Min;Hong, Min Jeong;Kim, Jin-Baek;Bae, Chang-Hyu;Kwon, Soon-Jae
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2018년도 추계학술대회
    • /
    • pp.43-43
    • /
    • 2018
  • Mutation breeding by radiation is useful for improving various crop species. Up to now, a total of 170 soybean mutant varieties have been released in the world, which is the second most registered varieties after rice. Despite the economic importance of soybean, there have been no TRAP marker system studies on genetic relationships between/among mutant lines. To develop a strategy of Mutant Diversity Pool (MDP) conservation, a study on the genetic diversity of 210 soybean mutant lines (8 cultivars and 202 mutants) was performed through a TRAP analysis. Sixteen primer combinations amplified a total of 551 fragments. The highest (84.00%) and lowest (32.35%) polymorphism levels were obtained with primers MIR157B + Ga5 and B14G14B + Ga3, respectively. The mean PIC values 0.15 varied among the primer combination ranging from 0.07 in B14G14B + Sal2 to 0.23 in MIR157B + Sa4. Phylogenetic, principal component analysis (PCA) and structure analysis indicated that the 210 lines belong to four groups based on the 16 combination TRAP markers. AMOVA showed 21.0% and 79.0% variations among and within the population, respectively. Overall, the genetic similarity of each cultivar and its mutants were higher than within other mutant populations. Our results suggest that the TRAP marker system may be useful for assessing the genetic diversity among soybean mutants and help to improve our knowledge of soybean mutation breeding.

  • PDF

사진측정(寫眞測定)에 의한 백제석탑(百濟石塔)의 조형미(造形美)에 관한 연구(硏究) (A Study on the Com positive Beauty of Back-Jae Stone Pagodas by means of Photogrammetry)

  • 유복모;강인준;정창식;송인성
    • 대한토목학회논문집
    • /
    • 제5권1호
    • /
    • pp.141-148
    • /
    • 1985
  • 본(本) 연구(硏究)는 현존(現存)하는 백제시대(百濟時代)의 두 석탑(石塔)인 미륵사지(彌勒寺址) 석탑(石塔)과 정림사지(定林寺址) 오층석탑(五層石塔)의 조형(造形)에 관한 기하학적(幾何學的) 해석(解析)이다. 두 석탑(石塔)을 지상측정용(地上測定用) Camera P31과 정밀입체도화(情密立體圖化)에 A-10을 이용하여 현존(現存) 복발(覆鉢)부분까지 남아있는 정림사지(定林寺址) 오층석탑(五層石塔)과 손상부분이 많은 미륵사지(彌勒寺址) 석탑(石塔)을 비교고찰(比較考察)한 결과 같은 조형원리(造形原理) 즉, 기준면(基準面)(module)으로부터 정삼각형을 작도하고 그 정삼각형의 정점(頂點) 윗부분에 있는 옥개석폭(屋蓋石幅)의 비(比)가 9 : 8 : 7 : 6 : (5)로 체감(遞減)되어 나가는 것을 알 수 있었고, 손상되기전의 복발(覆鉢)부분까지의 높이를 추정(推定)할 수 있었다.

  • PDF

Energy-band model on photoresponse transitions in biased asymmetric dot-in-double-quantum-well infrared detector

  • 신현욱;최정우;김준오;이상준;노삼규;이규석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.234-234
    • /
    • 2010
  • The PR transitions in asymmetric dot-in-double-quantum-well (DdWELL) photodetector is identified by bias-dependent spectral behaviors. Discrete n-i-n infrared photodetectors were fabricated on a 30-period asymmetric InAs-QD/[InGaAs/GaAs]/AlGaAs DdWELL wafer that was prepared by MBE technique. A 2.0-monolayer (ML) InAs QD ensemble was embedded in upper combined well of InGaAs/GaAs and each stack is separated by a 50-nm AlGaAs barrier. Each pixel has circular aperture of 300 um in diameter, and the mesa cell ($410{\times}410\;{\mu}m^2$) was defined by shallow etching. PR measurements were performed in the spectral range of $3{\sim}13\;{\mu}m$ (~ 100-400 meV) by using a Fourier-transform infrared (FTIR) spectrometer and a low-noise preamplifier. The asymmetric photodetector exhibits unique transition behaviors that near-/far-infrared (NIR/FIR) photoresponse (PR) bands are blue/red shifted by the electric field, contrasted to mid-infrared (MIR) with no dependence. In addition, the MIR-FIR dual-band spectra change into single-band feature by the polarity. A four-level energy band model is proposed for the transition scheme, and the field dependence of FIR bands numerically calculated by a simplified DdWELL structure is in good agreement with that of the PR spectra. The wavelength shift by the field strength and the spectral change by the polarity are discussed on the basis of four-level transition.

  • PDF

열수처리 시간에 따른 Ti-6Al-7Nh 합금의 생체활성 평가 (Evaluation of Bioactivity of Ti-6Al-7Nb Alloys with Various Hydrothermal Treatment Times)

  • 권오성;최석규;박광범;이민호;배태성;이오연
    • 한국재료학회지
    • /
    • 제14권12호
    • /
    • pp.876-884
    • /
    • 2004
  • This study was to investigate whether the bioactivity of the anodized and hydrothermally treated Ti-6Al-7Nb alloy were affected by the time of hydrothermal treatment. Anodizing was performed at current density 30 $mA/cm^2$ up to 300 V in electrolyte solutions containing $DL-{\alpha}-glycerophosphate$ disodium salt hydrate $(DL-{\alpha}-GP)$ and calcium acetate (CA). Hydrothermal treatment was done at $300^{\circ}C$ for 30 min, 1 hr, 2 hrs, and 4 hrs to produce a thin film layer of hydroxyapatite (HA). The bioactivity was evaluated from HA formation on the surfaces in a Hanks' solution with pH 7.4 at $36.5^{\circ}C$ for 10, 20, and 30 days. Anodic oxide films were porous with pore size of $1\sim4{\mu}m\;and\;3\sim4{\mu}m$ thickness. The anodic oxide films composed with strong anatase peak with presence of rutile peak, and showed the increase in intensity of anatase peak after hydrothermal treatment. It was shown that the intensity of anatase peak increased with increasing the time of hydrothermal treatment but was no difference in rutile peak. The corrosion voltage was the highest in the group of hydrothermal treatment for 2 hrs (Ecorr: -338.6 mV). The bioactivity in Hank's solution was accelerated with increasing the time of hydrothermal treatment.

How does duration of curing affect the radiopacity of dental materials?

  • Bejeh Mir, Arash Poorsattar;Bejeh Mir, Morvarid Poorsattar
    • Imaging Science in Dentistry
    • /
    • 제42권2호
    • /
    • pp.89-93
    • /
    • 2012
  • Purpose : Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher than that of the same thickness of aluminum. We aimed to investigate the possible effects of different curing times on the post-24-hour radiopacity of composite resins on digital radiographs. Materials and Methods : One mm thick samples of Filtek P60 and Clearfil resin composites were prepared and cured with three regimens of continuous 400 mW/$cm^2$ irradiance for 10, 20 and 30 seconds. Along with a 12-step aluminum step wedge, digital radiographs were captured and the radiopacities were transformed to the equivalent aluminum thicknesses. Data were compared by a general linear model and repeated-measures of ANOVA. Results : Overall, the calculated equivalent aluminum thicknesses of composite resins were increased significantly by doubling and tripling the curing times (F(2,8)=8.94, p=0.002). Notably, Bonferroni post-hoc tests confirmed that the radiopacity of the cured Filtek P60 was significantly higher at 30 seconds compared with 10 seconds (p=0.04). Although the higher radiopacity was observed by increasing the time, other comparisons showed no statistical significance (p>0.05). Conclusion : These results supported the hypothesis that the radiopacity of resin composites might be related to the duration of light curing. In addition to the current standards for radiopacity of digital images, defining a standard protocol for curing of dental materials should be considered, and it is suggested that they should be added to the current requirements for dental material.

Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge

  • Mir, Arash Poorsattar Bejeh;Mir, Morvarid Poorsattar Bejeh
    • Imaging Science in Dentistry
    • /
    • 제42권3호
    • /
    • pp.163-167
    • /
    • 2012
  • Purpose: ANSI/ADA has established standards for adequate radiopacity. This study was aimed to assess the changes in radiopacity of composite resins according to various tube-target distances and exposure times. Materials and Methods: Five 1-mm thick samples of Filtek P60 and Clearfil composite resins were prepared and exposed with six tube-target distance/exposure time setups (i.e., 40 cm, 0.2 seconds; 30 cm, 0.2 seconds; 30 cm, 0.16 seconds, 30 cm, 0.12 seconds; 15 cm, 0.2 seconds; 15 cm, 0.12 seconds) performing at 70 kVp and 7 mA along with a 12-step aluminum stepwedge (1 mm incremental steps) using a PSP digital sensor. Thereafter, the radiopacities measured with Digora for Windows software 2.5 were converted to absorbencies (i.e., A=-log (1-G/255)), where A is the absorbency and G is the measured gray scale). Furthermore, the linear regression model of aluminum thickness and absorbency was developed and used to convert the radiopacity of dental materials to the equivalent aluminum thickness. In addition, all calculations were compared with those obtained from a modified 3-step stepwedge (i.e., using data for the 2nd, 5th, and 8th steps). Results: The radiopacities of the composite resins differed significantly with various setups (p<0.001) and between the materials (p<0.001). The best predicted model was obtained for the 30 cm 0.2 seconds setup ($R^2$=0.999). Data from the reduced modified stepwedge was remarkable and comparable with the 12-step stepwedge. Conclusion: Within the limits of the present study, our findings support that various setups might influence the radiopacity of dental materials on digital radiographs.