• 제목/요약/키워드: MINI

검색결과 2,087건 처리시간 0.026초

Applicability of Mini-Cone Penetration Test Used in a Soil Box

  • Sugeun Jeong;Minseo Moon;Daehyeon Kim
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.83-92
    • /
    • 2023
  • In this study, we conducted verification of key influencing factors during cone penetration testing using the developed Mini Cone Penetration Tester (Mini-CPT), and compared the experimental results with empirical formulas to validate the equipment. The Mini-CPT was designed to measure cone penetration resistance through a Strain Gauge, and the resistance values were calibrated using a Load Cell. Moreover, the influencing factors were verified using a model ground constituted in a soil box. The primary influencing factors examined were the boundary effect of the soil box, the distance between cone penetration points, and the cone penetration speed. For the verification of these factors, the experiment was conducted with the model ground having a relative density of 63.76% in the soil box. It was observed that the sidewall effect was considerably significant, and the cone penetration resistance measured at subsequent penetration points was higher due to the influence between penetration points. However, within the speed range considered, the effect of penetration speed was almost negligible. The measured cone penetration resistance was compared with predicted values obtained from literature research, and the results were found to be similar. It is anticipated that using the developed Mini-CPT for constructing model grounds in the laboratory will lead to more accurate geotechnical property data.

Neer 분류 제 2형 원위부 쇄골 골절의 mini-T형 금속판 고정 (Mini-T Plate Fixation for Neer Type II Distal Clavicle Fracture)

  • 염재광;이상림;라호종
    • Clinics in Shoulder and Elbow
    • /
    • 제12권1호
    • /
    • pp.1-6
    • /
    • 2009
  • 목적: 불안정성 쇄골 원위부 골절에 대하여 mini-T 금속판을 이용한 수술적 치료를 시행 후 임상적 및 방사선학적 결과를 알아보고자 하였다. 대상 및 방법: 2004년 12월부터 2007년 7월까지 쇄골 원위부 골절 중 Neer 분류 제 2형인 불안정성 골절에 대하여 mini-T 금속판을 이용한 수술을 시행한 환자 중 1년 이상 추시 관찰이 가능하였던 15예를 대상으로 임상적 및 방사선학적 결과를 분석하였다. 결과: 방사선학적 골유합은 평균 3.1개월(3~4개월)에 이루어졌으며 심부 감염이나 고정 실패 등의 합병증은 없었다. 최종 추시 시 미국 견주관절학회 평가 점수(ASES score)는 평균 97점(85~100점)으로 양호한 결과를 보였으며, 견관절의 운동 범위도 1예를 제외하고 모든 예에서 정상으로 회복된 소견을 보였다. 결론: 불안정성 쇄골 원위부 골절에 대하여 mini-T 금속판을 이용한 수술 방법은 양호한 임상적 및 방사선학적 결과를 보여 좋은 수술 방법으로 사료되나 더 많은 증례를 통한 장기적인 결과 분석이 필요하리라 생각된다.

Maxillary protraction using customized mini-plates for anchorage in an adolescent girl with skeletal Class III malocclusion

  • Liang, Shuran;Xie, Xianju;Wang, Fan;Chang, Qiao;Wang, Hongmei;Bai, Yuxing
    • 대한치과교정학회지
    • /
    • 제50권5호
    • /
    • pp.346-355
    • /
    • 2020
  • The treatment of skeletal Class III malocclusion in adolescents is challenging. Maxillary protraction, particularly that using bone anchorage, has been proven to be an effective method for the stimulation of maxillary growth. However, the conventional procedure, which involves the surgical implantation of mini-plates, is traumatic and associated with a high risk. Three-dimensional (3D) digital technology offers the possibility of individualized treatment. Customized mini-plates can be designed according to the shape of the maxillary surface and the positions of the roots on cone-beam computed tomography scans; this reduces both the surgical risk and patient trauma. Here we report a case involving a 12-year-old adolescent girl with skeletal Class III malocclusion and midface deficiency that was treated in two phases. In phase 1, rapid maxillary expansion and protraction were performed using 3D-printed mini-plates for anchorage. The mini-plates exhibited better adaptation to the bone contour, and titanium screw implantation was safer because of the customized design. The orthopedic force applied to each mini-plate was approximately 400-500 g, and the plates remained stable during the maxillary protraction process, which exhibited efficacious orthopedic effects and significantly improved the facial profile and esthetics. In phase 2, fixed appliances were used for alignment and leveling of the maxillary and mandibular dentitions. The complete two-phase treatment lasted for 24 months. After 48 months of retention, the treatment outcomes remained stable.

미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구 (Multicentric retrospective clinical study on the clinical application of mini implant system)

  • 김영균;여인성;이양진;김운규;문경남;전승준;조용석;윤필영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권4호
    • /
    • pp.325-330
    • /
    • 2010
  • Introduction: Mini-implant system is applicable to areas of narrow space and area requiring temporary loading support. The purpose of this study was to evaluate the clinical outcome of a mini-implant system as well as the application of mini-implant system in the dental clinical field. Materials and Methods: The patients who had been operated from Jan 2007 to Dec 2007 in the four dental facility including Seoul National University Bundang Hospital were enrolled. To evaluate the factors associated with the clinical outcome, the patients were classified according to gender, age, area of surgery, type of implant, diameter and length of the implant, and the purpose of the mini-implant system application. Results: From 147 implants, only three implants failed, one of them was for temporary loading. There were no serious surgical or prosthetic complications in this study. Conclusion: An analysis of the preliminary data revealed a satisfactory clinical outcome. However, more long-term evaluation of narrow ridge type as well as the patient’s satisfaction on the use of a provisional type mini-implant system is needed.

Mini-Trampoline운동중 인체가 받는 중력가속도의 변화 (Evaluation of the Impact Acceleration Forces Attainable by Use of Mini-Trampoline)

  • ;주영은
    • The Korean Journal of Physiology
    • /
    • 제16권2호
    • /
    • pp.153-157
    • /
    • 1982
  • 수직뛰기 운동을 위한 mini-trampoline은 운동중 인체에 미치는 중력가속도를 변화시킴으로써 그 효과를 나타낸다고 하므로, mini-trampoline 운동중에 피검자가 받는 중력가속도를 다음과 같은 방법으로 측정하였다. 피검자로 하여금 mini-trampoline상에서 최대의 높이로 수직뛰기를 반복시키고, 그 뒷벽에는 3인치 간격의 눈금을 표시하여 뛰는 높이를 알 수 있게 하였다. 수직뛰기를 하는 동안에 super-8 mm 영사기로 초당 48 frames의 속도로 촬영한 후 각 frame에 나타난 피검자의 두정부 높이를 알아내었다. 수직뛰기하는 동안 시간에 대한 머리높이의 면화를 graph에 그려서 상승뛰기 운동시의 최대속도를 계산하였다. 이 결과로 부터 Arizona State University의 Crash Survival Investigator's School에서 고안한 다음의 공식을 사용하여 중력가속도(G)를 계산하였다. $$G={\frac{0.7854{\cdot}V^2}{32.2S}}$$ V = 상승운동시 나타난 최대속도 (fps) S = 하강운동시 정지거리 (ft) 본 연구에서 V는 약 9fps 였고, S는 0.61 ft 였으며 따라서 G는 $3.24+G_z$였다. 인체가 친밀 수 있는 증력가속도의 한계가 $+G_z$방향으로 0.1초동안 20G이며 $-G_z$방향으로 0.1초 동안 15G임을 고러할 때 mini-trampoline운동으로써 얻을 수 있는 중력가속도는 인체에 유해할 만큼 큰 것이 아니라는 것을 알 수 있다.

  • PDF

The photocatalytic activities of nano-titanium dioxide on the cotton fabrics for self-cleaning properties

  • Metanawin, Siripan;Metanawin, Tanapak;Panutumrong, Praripatsaya;Hathaiwaseewong, Sunee;Chaichalermvong, Tirapong
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.129-137
    • /
    • 2015
  • The study of photocatalysis of nano titanium dioxideon the cotton fabrics have been investigatedthrough self-cleaning properties. The mini-emulsion technique was employed to prepare the encapsulation of titanium dioxide nano particles in polystyrene beads prior used. The mini-emulsion was coated on the cotton fabrics using Pad-dry method.The loading amount of TiO2particles into the mini-emulsion were various from 1%wt to 40%wt. The particles sizes of the TiO2-encapsulated polystyrene mini-emulsion were investigated by dynamic light scattering. It was noticed that the particle size of the mini-emulsion was in the range of 100- 200 nm. The morphology of treated cotton fabrics were investigated using scanning electron microscopy. The crystal structure of TiO2-encapsulated PS mini emulsion which coated on cotton fabrics were examined by X-ray diffraction spectroscopy. In order to investigate the photocatalytic activities of TiO2 through the selfcleaning characteristics of the cotton fabrics, colorant stains were created on the samples. Coffee stains were used as colorant organic stains. The result shown that the coffee stained on the cotton fabrics significantly showed the improving of the self-cleaning properties under UV radiation.

접촉 유한요소모델을 이용한 미니 임플란트의 초기 응력분포 연구 (Contact non-linear finite element model analysis of initial stability of mini implant)

  • 윤현주;정의원;이종석;김창성;김정문;조규성;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.681-690
    • /
    • 2007
  • Mini implants had been used provisionally for the healing period of implants in the beginning. But it becomes used for the on-going purpose, because it is simple to use, economic and especially suitable for the overdenture. But there is few studies about the stability of mini implants, that is most important factor for the on-going purpose, and particularly the implant parameters affecting the initial stability. The purpose of this study was to evaluate the stress and the strain distribution pattern of immediate-loaded screw type orthodontic mini-implant and the parameters affecting the initial stability of immediate-loaded mini-implant. Two dimensional finite element models were made and contact non-linear finite element analysis was performed. The magnitude and distribution of Von Mises stresses were evaluated. The obtained results were as follows: 1. The stress was concentrated on the thread tip of an implant in the cortical bone. 2. The direction of load is the most important factor for the stress distribution in cortical bone. 3. The diameter of an implant is the most important factor for the stress distribution in the trabecular bone. In conclusion, if the horizontal load vector is successfully controlled, mini-implants, which diameter is under 3mm, can be used for the on-going purpose.

Creation of an Ethanol-Tolerant Yeast Strain by Genome Reconstruction Based on Chromosome Splitting Technology

  • Park, A-Hwang;Sugiyama, Minetaka;Harashima, Satoshi;Kim, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권2호
    • /
    • pp.184-189
    • /
    • 2012
  • We sought to breed an industrially useful yeast strain, specifically an ethanol-tolerant yeast strain that would be optimal for ethanol production, using a novel breeding method, called genome reconstruction, based on chromosome splitting technology. To induce genome reconstruction, Saccharomyces cerevisiae strain SH6310, which contains 31 chromosomes including 12 artificial mini-chromosomes, was continuously cultivated in YPD medium containing 6% to 10% ethanol for 33 days. The 12 mini-chromosomes can be randomly or specifically lost because they do not contain any genes that are essential under high-level ethanol conditions. The strains selected by inducing genome reconstruction grew about ten times more than SH6310 in 8% ethanol. To determine the effect of mini-chromosome loss on the ethanol tolerance phenotype, PCR and Southern hybridization were performed to detect the remaining mini-chromosomes. These analyses revealed the loss of mini-chromosomes no. 11 and no. 12. Mini-chromosome no. 11 contains ten genes (YKL225W, PAU16, YKL223W, YKL222C, MCH2, FRE2, COS9, SRY1, JEN1, URA1) and no. 12 contains fifteen genes (YHL050C, YKL050W-A, YHL049C, YHL048C-A, COS8, YHLComega1, ARN2, YHL046W-A, PAU13, YHL045W, YHL044W, ECM34, YHL042W, YHL041W, ARN1). We assumed that the loss of these genes resulted in the ethanol-tolerant phenotype and expect that this genome reconstruction method will be a feasible new alternative for strain improvement.

항생제를 사용하고 있었던 인공호흡기 연관 폐렴환자에서의 원인균 발견을 위한 소량 기관지폐포세척술의 진단적 효용성에 관한 연구 (Study for Diagnostic Efficacy of Minibronchoalveolar Lavage in the Detection of Etiologic Agents of Ventilator-associated Pneumonia in Patients Receiving Antibiotics)

  • 문두섭;임채만;배직현;김미나;진재용;심태선;이상도;김우성;김동순;김원동;고윤석
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권3호
    • /
    • pp.321-330
    • /
    • 1999
  • 배경: 인공호흡기 연관 폐렴(ventilator-associated pneumonia, 이하 VAP)의 원인균 동정의 표준적인 방법으로는 기관지내시경을 통한 검체보호솔질법(protected specimen brush, 이하 PSB)이 인정되고 있다. 그러나 PSB가 고가이고 국내의 경우 전량 수입에 의존하고 있어 보편적으로 사용하기 어렵다. VAP의 진단에는 PSB외에 기관지폐포세척술(bronchoalveolar lavage, 이하 BAL)이 흔히 이용되나 호흡부전으로 인공호흡기를 사용하는 환자에서 다량의 BAL을 시행하기 어렵고, 시술 후 환자 상태가 악화될 수도 있다. 이에 저자들은 기왕에 항생제를 투여 받고 있던 중 VAP가 발생한 환자들을 대상으로 바이러스를 포함한 원인균의 동정 검사에 필요한 최소한의 BAL검체(25 ml) 만 채취하는 소량의 BAL(이하 miniBAL)을 시행하여 동일한 부위에서 시행한 PSB에 의한 세균 배양 검사 성적과 비교함으로써 miniBAL 검사의 진단적 효용성을 알아보고자 하였다. 방법: 연구는 1997년 5월 1일부터 1998년 8월 31일까지 서울 중앙병원 성인 중환자실에서 항생제를 투여 받고 있던 중 연속적으로 VAP가 발생한 38명(41 예)의 환자를 대상으로 하였다. 환자들의 평균연령은 $61{\pm}14$세이었으며 남녀 비는 3.6:1 이었다. PSB는 단순 흉부사진상 병변이 심한 부위에서 시행하였고, 동일부위에서 miniBAL을 연속적으로 시행하였다. miniBAL은 생리식염수를 50 ml씩 투여하여 총 25 ml가 모일 때까지 세척을 반복하였다. VAP 원인균의 판정 기준은 PSB와 BAL을 통해 얻은 검체를 정량 배양법으로 배양한 뒤 PSB는 $10^3cfu/ml$ 이상, BAL은 $10^4cfu/ml$ 이상인 경우에 양성으로 판정하였다. 결과: 25 ml BAL을 얻기 위해 기관지 내시경을 통해 주입한 생리 식염수의 양은 평균 $93{\pm}32ml$ 였다. PSB의 경우에는 총 41예 중 19예(46.3%), miniBAL의 경우 18예(43.9%)에서 원인균이 검출되었다. PSB와 miniBAL은 41예 중에서 35예에서 일치하는 결과를 나타내어 진단 일치율은 85.4%였다. VAP가 호전된 환자는 39명 중에서 19명(48.7%)이었고 miniBAL과 PSB를 통해 원인균이 발견된 환자들(12/19 명, 63.2%)이 발견되지 않았던 환자들(7/20명, 35%)에 비해 VAP 호전율은 높았으나 두 군사이의 통계학적 차이는 없었다(P>0.2). 검사 전, 검사 중 그리고 검사 후의 분당 평균 심 박동수는 각각 $111{\pm}22$회, $125{\pm}24$회, $111{\pm}26$회이었으며 동맥혈 산소분압은 각각 $97{\pm}3%$, $92{\pm}10%$, $95{\pm}3%$ 이었다. 검사 전파 검사 중의 심 박동수는 유의하게 증가되었으나 (p<0.05) 검사 전과 검사 10분 후의 심 박동수는 차이가 없었다(p>0.5). 검사 전과 비교하여 검사 중과 (p<0.05) 검사 후의 (p<0.005) 동맥혈 산소포화도는 유의하게 저하되었으나 모두 정상범위 내에 있었다. 검사 시행 중 저혈압 2예, 동맥 산소 분압의 저하 3 예의 부작용이 있었으나 검사 종료후 곧 회복되었고, 심방조동(atrial flutter)으로 l예에서 검사가 중단되었으나 8일 후에 문제 없이 miniBAL이 시행되었다. 결론: MiniBAL 배양검사의 결과는 PSB에 의한 결과와 높은 일치율을 보이고 비교적 안전한 검사방법이므로 VAP 의 원인균 규명에 PSB와 고식적인 BAL을 대치할 수 있는 진단 방법으로 사료된다.

  • PDF

천식 및 만성폐쇄성폐질환 환자에서 Mini-Wright Peak Flowmeter로 측정한 최대호기유속의 정확도 (An Evaluation of the Accuracy of Mini-Wright Peak Flowmeters in Patients with Asthma and Chronic Obstructive Pulmonary Disease)

  • 최원일;한승범;전영준
    • Tuberculosis and Respiratory Diseases
    • /
    • 제50권3호
    • /
    • pp.310-319
    • /
    • 2001
  • 연구배경 : 천식의 치료에 널리 사용되고 있는 호기유속측정기는 외래환자와 응급실에서뿐만 아니라 입원 천식환자들의 치료 및 경과 관찰에 매우 유용하다. 호기유속측정기에 대한 정확도 및 재현성에 대한 많은 연구가 있어왔으나 기류폐색을 가지는 환자를 대상으로 측정했을때의 정확도에 관한 연구는 드물다. 따라서 만성폐쇄성폐질환 또는 천식을 가지는 환자를 대상으로 잘 보정된 mass flow sensor의 최대호기유속 측정치와 mini-Wright peak flowmeter의 측정치를 비교하여 정확도를 관찰하고자 본 연구를 계획하였다. 방 법 : 천식 및 만성페쇄성폐질환으로 진단된 환자 108명을 대상으로 흡입용 기관지확장제 사용 전 후의 최대호기유속을 측정하였으며 잘 보정된 mass flow sensor로 측정한 후 mini-Wright peak flowmeter를 사용해서 최대호기유속을 측정하였다. 결 과 : 천식 및 만성폐쇄성폐질환 환자에서 mini-Wright peak flowmeter로 측정한 최대호기유속 값은 기관지 확장제 사용 유무에 관계없이 mass flow sensor의 측정치보다 평균 37-39 l/min 높게 관찰되었고 300 l/min 이하의 범위에서 오차는 25% 이상이었고 301 l/min 이싱에서는 17% 이하로 관찰되었다. 두 기기로 측정한 값의 일치도를 평가할 수 있는 편의(bias)는 전체를 대상으로 했을 때와 유속의 정도에 따라서도 모두 일치범위를 벗어나고 통계적으로도 유의하게 차이가 있었다. 결 론 : 천식 및 만성폐쇄성폐절환 환자에서 mini-Wright peak flow meter로 측정한 최대호기유속은 mass flow senor의 측정치보다 높게 관찰되었으며 300 l/mm이하의 유속에서 오차가 심했다. 두 기계로 측정한 최대호기유속 사이의 일치범위는 95% 신뢰구간에서 통계적으로 유의한 차이가 있었으므로 mass flow sensor 와 mini-Wright peak flow meter로 측정 한 결과를 상호교환적으로 사용할 수 없다고 판단된다.

  • PDF