• Title/Summary/Keyword: MEV

Search Result 57, Processing Time 0.024 seconds

Correlation Analysis and Estimation Modeling Between Road Environmental Factors and Traffic Accidents (The Case of a 4-legged Signalized Intersections in Cheongju) (도로환경요인과 교통사고의 상관분석 및 사고추정모형 개발 (청주시 4지 신호교차로를 중심으로))

  • Park, Jeong-Sun;Kim, Tae-Yeong;Yu, Du-Seon
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.2 s.95
    • /
    • pp.63-72
    • /
    • 2007
  • The purpose of this study is to develop a traffic characteristic analysis, a correlation analysis with the variables of traffic characteristics, and accident estimation models while recognizing the seriousness of the traffic accidents. The analyses deal with the 181 4-legged signalized intersections that accounted for 1,183 out of 3,115 accidents in Cheongju in 2004. After measuring ADT, intersection area, average lane width, elevation, and other items as independent variables and the number of traffic accidents, the traffic accident rate (accidents per million entering vehicles) and equivalent property damage only (EPDO) figures as dependent variables which are estimated as influencing signalized intersection accidents, the estimation models are developed using correlation analysis and multiple regression analysis. In the analysis of the number of traffic accidents, the model indicates an $R^2$ of 0.612, and five independent variables are taken as significant factors. In the analysis of traffic accident rates, the model indicates an $R^2$ of 0.304 and five significant factors, including intersection area and ADT. Also, for the analysis or the EPDO numbers, which coincides with understanding the seriousness of the traffic accidents and the traffic characteristic analysis, the model indicates an $R^2$ of 0.559, and four independent variables (ADT, main street average lane width, elevation, and speed limit) as significant factors.

유기물 내의 트랩이 전자 이동도에 미치는 전기적 영향

  • Park, Jae-Hyeon;Kim, Tae-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.328.2-328.2
    • /
    • 2016
  • 유기물을 사용한 차세대 전자 소자는 간단한 공정과 3차원의 고집적, 그리고 플렉서블한 특성을 가지고 있다. 이러한 유기물을 사용한 차세대 전자 소자를 설계하기 위해서는 유기물 내에서의 전하 전송을 이해하는 것이 중요한데, 특히 유기물의 전자이동도에 대한 연구가 필요하다. 본 연구에서는 시뮬레이션을 위하여 소자의 길이를 30-300 사이트로 설계하였고, 사이트간 거리를 $3{\AA}$으로 설정하였다. 유기물 내의 트랩을 가우시안 분포로 분포시켰고, 트랩이 퍼져있는 정도와 총량을 조절하였다. 그리고 몬테카를로 시뮬레이션 방법으로 계산하여 유기물 내에서 트랩이 전자이동도에 미치는 영향을 분석하였다. Miller and Abrahams 식을 이용하여 천이확률을 계산하였는데, 트랩분포가 일정할 경우 전계가 증가함에 따라 전자의 이동도가 증가하였다. 이때 전계의 증가에 따라 유기물 내 트랩 간 천이 확률이 증가하였는데, 이 때문에 전자의 이동도가 증가함을 알 수 있었다. 그러나 전계가 일정 값 이상으로 중가 할 때는 전자의 이동 속도 또한 거의 변하지 않아 전자의 이동도는 오히려 줄어들었다. 트랩의 분산도를 증가시켰을 경우 낮은 전계 영역에서는 전자 이동도가 작고, 트랩의 분산도가 30 mev로 작을 경우에는 일정온도이상에서는 전자 이동도가 일정하게 유지되었다. 그리고 분산도와 무관하게 전계가 증가하였을 때 전자 이동도의 변화는 거의 없었다. 이와 같은 시뮬레이션을 통하여 유기물 내에서 트랩과 온도가 전자 이동도에 미치는 영향을 확인할 수 있었다. 이러한 결과를 토대로 전하전송을 이해하면 유기물질을 이용한 소자 설계 시 소자 특성 향상에 도움을 줄 수 있을 것으로 기대된다.

  • PDF

Process and Structure Design for High Power Reverse-Conducting Gate Commutated Thyristors (RC- GCTs) (고전압 역도통 Gate Commutated Thyristor (RC-GCT) 소자의 공정 및 구조 설계)

  • Kim, Sang-Cheol;Kim, Eun-Dong;Zhang, Chang-Li;Kim, Nam-Kyun;Baek, Do-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.1096-1099
    • /
    • 2001
  • The basic design structure of RC-GCTs (Reserve-Conducting Gate-Commutated Thyristors) is firstly given in this paper. The bulk of wafer is punch-through (PT) type with high resistivity and narrow N-base width. The photo-mask was designed upon the turn-off characteristics of GCT and solution of separation between GCT and diode part. The center part of Si wafer is free-wheeling diode (FWD) and outer is GCT part which has 240 fingers totally. The switching performance of GCT was investigated by Dessis of ISE. The basic manufacture process of 2500V-4500V RC-GCTs was given in this work. Additionally, the local carrier lifetime control by 5Mev proton irradiation was adopted so as to not only to have the softness of reverse recovering for FWD but for reduction of turn-off losses of GCT as well.

  • PDF

AN EXPERMENTAL STUDY ON THE EFFECTS OF COBALT-60 RADIATION OF THE TEETH OF THE RAT (Co-60 방사선 조사가 백서 치아에 미치는 영향에 관한 실험적 연구)

  • Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.61-68
    • /
    • 1982
  • This study was undertaken to compare the histopathological effects of the fractionated doses of 2,400, 4,800 and 7,200 rads of Cobalt-60 irradiation on the teeth of the sixty eight rats (Wester strain), weighing approximately 130gm. They were devided into four groups; no irradiation as a control (Group I) and others (Group II, III, and IV) which received different doses of radiation using 1.25 Mev RAC-120 Cobalt-60 Teletherapy Unit with exposure dose rate 69 rads/min, TSD 80cm. Experimental animals received 600 rads every three days until the total dosage of their groups were reached. Experimental animals were sacrified at the 1st day, 1st, 2nd, 3rd, 4th, 5th and 6th week irradiation. The following histopathologic findings were obtained: 1. The Group II, received 2,400 rads, showed no histopamologic changes essentially same as those of the control Group. 2. In the Groups III and IV, received 4,800 rads and 7,200 rads, disarray of the normal palasading arrangement of the odontoblastic cells, vacuolar degeneration in the odontoblastic layer, osteodentin and dentinal niches in the anterior teeth were observed. 3. There were no distinct changes in the posterior teeth in the Groups III and IV. 4. The ameloblast cells seemed to be less sensitive to radiation damage than the odontoblast cells.

  • PDF

Attenuation curves of neutrons from 400 to 550 Mev/u for Ca, Kr, Sn, and U ions in concrete on a graphite target for the design of shielding for the RAON in-flight fragment facility in Korea

  • Lee, Eunjoong;Kim, Junhyeok;Kim, Giyoon;Kim, Jinhwan;Park, Kyeongjin;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.275-283
    • /
    • 2019
  • Rare isotope beam facilities require shielding data in early stage of their design. There is much less shielding data on neutrons from the reactions between heavy ion beams and matter than the data on neutrons produced by protons. The purpose of the present work is to produce and thus increase the amount of shielding data on neutrons generated by high-energy heavy ion beams based on the RAON in-flight fragment facility. Calculations were performed with the computational Monte Carlo codes PHITS and MCNPX. The secondary neutron source terms were evaluated at 550 MeV/u for Ca, Kr, and Sn and at 400 MeV/u for U ions on a graphite target. Source terms and attenuation lengths were obtained by fitting the ambient dose equivalent inside an ordinary concrete shield.

A study of electrical characteristic of MOSFET device (고에너지 이온주입에 따른 격자 결함 발생 및 거동에 관한 열처리 최적화방안에 관한 연구)

  • Song, Young-Doo;Kwack, Kae-Dal
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1830-1832
    • /
    • 1999
  • 고에너지 이온주입(1)에 기인한 격자 손상 발생 및 열처리에 따라 이들의 회복이 어느정도 가능한지에 대하여 측정 및 분석방법을 통하여 조사하였다. 그리고 본 실험에서는 이온주입시 형성되는 빈자리 결함(Vacancy defect)과 격자간 결함(interstitial defect)의 재결할(recombination)을 이용 점결합(point defect)를 감소 시킬 수 있는 effective RTA조건을 설정하여 well 특성을 개선하고자 하였다. 8inch p-type Si(100)기판에 pad oxide 100A을 형성한 후 NMOS 형성하기 위해 vtn${\sim}$p-well과 PMOS 형성을 위해 vtp$\sim$n-well을 이온주입 하였다. Mev damage anneal은 RTA(2)(Rapid Thermal Anneal)로 $1000\sim1150C$ 온도에서 $15\sim60$초간 spilt 하여 실험후 suprem-4 simulation data를 이용하여 실제 SIMS측정 분석결과를 비교하였으며 이온주입에 의해 발생된 격자손상이 열처리후 damage 정도를 알아보기 위해 T.W(Therma-Wave)을 이용하였으며 열처리후 면저항값은 4-point probe를 사용하였다. 이온주입후 열처리 전,후에 따른 불순물 분포를 SIMS(Secondary ion Mass Spectrometry)를 이용하여 살펴보았다. SIMS 결과로는 열처리 온도 및 시간의 증가에 따라서 dopant확산 및 활성화는 큰차이는 보이지 않고 오히려 감소하는 경향을 볼 수 있으며 또한 접합깊이와 농도가 약간 낮아지는 것을 볼 수 있었다. 결점(defect)을 감소시키기 위해서 diffusivity가 빠른 임계온도영역($1150^{\circ}C$-60sec)에서 RTA를 실시하여 dopant확산을 억제하고 점결점(point defect)의 재결합(recombination)을 이용하여 전위 (dislocation)밀도를 감소시켜 이온주입 Damage 및 면저항을 감소 시켰다. 이와 같은 특성을 process simulation(3)(silvaco)을 통하여 비교검토 하였다.

  • PDF

Radiotherapy Technique of High Energy Electron (고에너지 전자선의 방사선 치료 기술)

  • SUH M.W.;PARK J.I.;CHOI H.S.;KIM W.Y.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 1985
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefore, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed does, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under $3\%$ errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under $5\%$ errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatters; i.e., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Studies on Dose Distribution and Treatment Technique of High Energy Electron (고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究))

  • Lee, D.H.;Chu, S.S.
    • Journal of Radiation Protection and Research
    • /
    • v.3 no.1
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

A Study on Dobe Distribution at the Junction of $^{60}CO\;\gamma-Ray$ and Elecron Beam in Postoperative Radiotherapy of Breast Cancer (유암수술후 방사선치료시 $^{60}Co\;\gamma$선과 전자선 조사야 접합부 선량분포에 관한 연구)

  • Kang, Wee-Saing;Huh, Seung-Jae;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.149-153
    • /
    • 1984
  • Postoperative radiotherapy of breast cancer makes it possible to reduce loco-regional recurrence of breast cancer. The treatment technique, which can reduce the low-dose region at the junction and lung, is required. To produce proper dose distribution of internal mammary chain and chest wall, authors tried to find the method to expose $^{60}Co\;\gamma-ray$ on internal mammary region and 7MeV electron on chest wall. Exposure time of $^{60}Co\;\gamma$ and monitor unit of 9MeV were selected so that dose of $^{60}Co$ at 4cm depth was the same as that of 7Mev electron at $80\%$ dose depth. The position and direction of electron beam were changed for $^{60}Co$ beam: $0^{\circ},\;5^{\circ}$ for 0cm seperation; $0^{\circ},\;5^{\circ},\;10^{\circ}$ for 0.5cm seperation; $5^{\circ},\;10^{\circ},\;15^{\circ}$ for 1cm seperation. The results are as followings. 1. When the seperation of two fields was increased, dose on the axis of $^{60}Co$ beam was increased and dose at the junction region decreased while the volume of lung to be exposed to high dose and hot spot size were irregularly changed. 2. The dose distribution in the target volume of internal mammary and chest wall was most ideal when the seperation of two fields was $0\~0.5cm$ and the direction of electron beam was parallel to $^{60}Co$ beam.

  • PDF

EXPERIMENTAL ANALYSES OF SPALLATION NEUTRONS GENERATED BY 100 MEV PROTONS AT THE KYOTO UNIVERSITY CRITICAL ASSEMBLY

  • Pyeon, Cheol Ho;Azuma, Tetsushi;Takemoto, Yuki;Yagi, Takahiro;Misawa, Tsuyoshi
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.81-88
    • /
    • 2013
  • Neutron spectrum analyses of spallation neutrons are conducted in the accelerator-driven system (ADS) facility at the Kyoto University Critical Assembly (KUCA). High-energy protons (100 MeV) obtained from the fixed field alternating gradient accelerator are injected onto a tungsten target, whereby the spallation neutrons are generated. For neutronic characteristics of spallation neutrons, the reaction rates and the continuous energy distribution of spallation neutrons are measured by the foil activation method and by an organic liquid scintillator, respectively. Numerical calculations are executed by MCNPX with JENDL/HE-2007 and ENDF/B-VI libraries to evaluate the reaction rates of activation foils (bismuth and indium) set at the target and the continuous energy distribution of spallation neutrons set in front of the target. For the reaction rates by the foil activation method, the C/E values between the experiments and the calculations are found around a relative difference of 10%, except for some reactions. For continuous energy distribution by the organic liquid scintillator, the spallation neutrons are observed up to 45 MeV. From these results, the neutron spectrum information on the spallation neutrons generated at the target are attained successfully in injecting 100 MeV protons onto the tungsten target.