• Title/Summary/Keyword: Lung, CT

Search Result 855, Processing Time 0.033 seconds

Computed Tomographic Diagnosis of Bronchiectasis in a Dog with Chronic Bronchopneumonia (만성 기관지폐염 견에서 컴퓨터단층촬영을 통한 기관지확장증 진단 1례)

  • Lim Chang-yun;Choi Ho-jung;Jeong Yu-cheol;Oh Sun-kyoung;Seo Eun-jung;Jung Joo-hyun;Choi Min-cheol;Yoon Junghee
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.431-434
    • /
    • 2005
  • A 2-year-old castrated male, Cocker spaniel dog with a history of chronic productive cough for 2 to 3 months and with unsuccessful treatment was referred to Veterinary Medical Teaching Hospital, Seoul National University. On thoracic radiographs, there were alveolar infiltrations at left cranial and right caudal lung fields, and soft-tissue opacity round to oval images at overall lung field. The bronchi were dilated, tortuous and not tapered. Abnormal air was accumulated focally in the caudodorsal lung fields. To scrutinize the soft-tissue opacity image and accumulated air, computed tomography (CT) was done. On CT images, severe cylindrical or tubular bronchiectasis was confirmed. And the soft-tissue opacity images were found in the dilated bilated and thought to complexes of mucous plugs, inflammatory cells, necrotic and fibrotic tissue. The dog was dead next day to the CT scan, so necropsy and histopathologic examination were perfermed. On the histopathology, there were cylindrical bronhiectasis and severe diffuse chronic fibrinous necropurulent bronchitis and bronchopneumonia. In this case, it was difficult to diagnose the bronchiectasis only with radiography due to the concurrent lesions, such as pulmonary infiltrations and mucous plugs, which was identified by computed tomography. Thus, computed tomography is considered as a useful modality to confirm tile bronchiectasis camouflaged by the concurrent lesion.

Automatic Lung Segmentation using Hybrid Approach (하이브리드 접근 기법을 사용한 자동 폐 분할)

  • Yim, Yeny;Hong, Helen;Shin, Yeong-Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.7
    • /
    • pp.625-635
    • /
    • 2005
  • In this paper, we propose a hybrid approach for segmenting the lungs efficiently and automatically in chest CT images. The proposed method consists of the following three steps. first, lungs and airways are extracted by two- and three-dimensional automatic seeded region growing and connected component labeling in low-resolution. Second, trachea and large airways are delineated from the lungs by two-dimensional morphological operations, and the left and right lungs are identified by connected component labeling in low-resolution. Third, smooth and accurate lung region borders are obtained by refinement based on image subtraction. In experiments, we evaluate our method in aspects of accuracy and efficiency using 10 chest CT images obtained from 5 patients. To evaluate the accuracy, we Present results comparing our automatic method to manually traced borders from radiologists. Experimental results show that proposed method which use connected component labeling in low-resolution reduce processing time by 31.4 seconds and maximum memory usage by 196.75 MB on average. Our method extracts lung surfaces efficiently and automatically without additional processing like hole-filling.

Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications

  • Wonju Hong;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1203-1212
    • /
    • 2021
  • Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.

A Case of Adenocarinoma of the Lung Associated with Multi-oragn Infarctions (다발성 장기 경색을 동반한 폐선암 1례)

  • Park, Chang-Whan;Lee, Chung-Hoon;Whang, Jun-Wha;Jang, Il-Gwon;Park, Hyeong-Kwan;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1177-1183
    • /
    • 1997
  • The relationship between neoplastic disease and thromboembolic disorders has been recognized since 1865, when Armand Trousseau first reported a high incidence of venous thrombosis in a series of patients with gastric carcinoma. The overall incidence of thromboembolic disease in patients with cancer has been reported to vary 1% to 15%. In a prospective study, Ambrus and associates reported that thrombosis and/or bleeding was the second most common cause of death in haspitalized cancer patients. We report a case who presented as a thromboembolic disease and subsequently confirmed to have an underlying lung malignancy. This 45 years old male patient visited our hospital with abdominal pain and distention of 3 days duration. Abdominal CT scan revealed multiple splenic and renal infarctions. On 20th haspital day, drowsy mental status was developed and hemorrhagic cerebral infarction was noted in brain CT scan. Chest CT scan revealed a 4cm sized spiculated mass on left lung apex and multiple paratracheal lymph adenopathy. With surgical biopsy of left supraclavicular lymph nodes, this patient was confirmed to have adenocarcinoma.

  • PDF

Promoter demethylation mediates the expression of ZNF645, a novel cancer/testis gene

  • Bai, Gang;Liu, Yunqiang;Zhang, Hao;Su, Dan;Tao, Dachang;Yang, Yuan;Ma, Yongxin;Zhang, Sizhong
    • BMB Reports
    • /
    • v.43 no.6
    • /
    • pp.400-406
    • /
    • 2010
  • Cancer/testis (CT) antigens exhibit highly tissue-restricted expression and are considered promising targets for cancer vaccines. Here we identified a novel CT gene ZNF645 which restrictively expresses in normal human testes and lung cancer patients (68.3%). To investigate the promoter methylation status of ZNF645, we carried out bisulfite genomic sequencing and found that the CpG island in its promoter was heavily methylated in normal lung tissues without the expression of ZNF645, whereas there was high demethylation in normal human testes and lung carcinoma tissues with its expression. Also ZNF645 could be remarkably activated in A549 and HEK293T cells treated by DNA demethylation agent 5'-aza-2'-deoxycytidine. And the dual luciferase assay revealed that the promoter activity of the ZNF645 was inhibited by methylation of the CpG island region. Therefore, we proposed that ZNF645 is a CT gene and activated in human testis and lung cancers by demethylation of its promoter region.

The Effectiveness of Spiral Computed Tomography as a Diagnostic Tool in Pulmonary Embolism(Comparison of Spiral CT with Ventilation-Perfusion Scan) (폐색전증 진단의 도구로서의 Spiral Computed Tomography의 유용성(폐환기관류주사와의 비교))

  • Koh, Jae-Hyun;Oh, Eun-Young;Park, Jung-Ho;Park, Sang-Joon;Yun, Jung-Hwan;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.564-573
    • /
    • 1999
  • Background: With variable symptoms and nonspecific radiographic appearances, pulmonary embolism (PE) is a frequent and often undiagnosed cause of mortality and morbidity. The Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study suggested that the majority of patients undergoing ventilation-perfusion (V-Q) scan would require additional studies to establish or to exclude the diagnosis of PE. Pulmonary angiography has been regarded as gold standard for diagnosis of PE. However, it is an invasive procedure that may be associated with significant notable morbidity and mortality. Thus, availability of an accurate, noninvasive screening examination is highly desirable. Method: From October 1994 to February 1997, twenty patients (male 13, female 7, range 23-91 years, median 58 years) who were suspected as pulmonary embolism on the basis of clinical evidence and underwent the spiral volumetric computed tomography (spiral CT), were studied retrospectively to evaluate the effectiveness of spiral CT as a diagnostic tool in PE. Results: PE could be excluded with spiral CT in 4 patients ; diagnoses of these patients were lung cancer, pneumonia with lung abscess, bilateral pleural effusion due to congestive heart failure, nonspecific pulmonary abnormality retrospectively. One patient who disclosed high probability in V/Q scan, could be diagnosed as pneumonia with lung abscess and underlying emphysema with spiral CT. Among 4 patients who showed intermediate and low probability in V/Q scan, 3 patients could be confirmed as PE with spiral CT. Spiral CT was helpful in 3 patients, in whom V/Q scan could not be performed due to other reasons (e.g. night time, mechanical ventilation) to confirm the diagnosis of PE. Spiral CT could demonstrate embolus above lobar artery level in 11 patients, and up to segmental artery level in 5 patients. Conclusion: This study demonstrated that spiral CT could allow accurate demonstration of thrombotic clots in centrally localized embolism. Spiral CT could be effective, specific, noninvasive and useful diagnostic screening modality for the diagnosis of pulmonary embolism.

  • PDF

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Correlation of Pre-treatment FDG Uptake to Therapeutic Response and Relapse in Patients with Small Cell Lung Cancer (소세포폐암의 치료전 FDG섭취와 치료반응 및 재발과의 연관성)

  • Seo, Young-Soon;Kwon, Seong-Young;Jeong, Shin-Young;Song, Ho-Chun;Min, Jung-Joon;Kim, Kyu-Sik;Kim, Young-Chul;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.538-545
    • /
    • 2007
  • Purpose: We evaluated correlation of $^{18}F$-FDG uptakes, therapeutic response and relapse in pre-treatment $^{18}F$-FDG PET/CT in patients with SCLC. Materials and methods: We included 26 patients with pathologically proven small cell lung cancer. Total 102 lesions (26 lungs, 69 lymph nodes and 8 metastatic lesions) were evaluated. All patients underwent $^{18}F$-FDG PET/CT for staging. The maxSUV was used as a parameter of $^{18}F$-FDG uptake. The patients were divided into responders and non-responders according to response criteria on chest CT scan after 3 cycles of chemotherapy. We compared maxSUV between two groups by using independent t-test. To access correlation with $^{18}F$-FDG uptake and relapse, maxSUV and interval time to relapse was analyzed by correlation analysis. The cutoff value of maxSUV was evaluated by ROC curve. Results: Twelve-one patients (81%) were responders and five patients were non-responders on follow-up chest CT scan. The mean maxSUV of main lung lesions in responders and non-responders were $14.15{\pm}3.72$ and $9.17{\pm}2.15$, respectively. The maxSUV in the responders was significantly lower than that in non-responders (p<0.05). According to ROC curve, point of cut that predicts therapeutic response was 8.98 with 100% sensitivity and 57% specificity. The correlation analysis between $^{18}F$-FDG uptakes and interval time to relapse showed a significant negative correlation (p<0.05, r=-0.757). Conclusion: The pre-treatment $^{18}F$-FDG uptake of responders was significantly lower than that of non-responders. Patients with high $^{18}F$-FDG uptake in pre-treatment $^{18}F$-FDG PET/CT relapse earlier.

A Study on the PET/CT Fusion Imaging (PET/CT 결합영상진단 검사에 관한 연구)

  • Kim, Jong Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.193-198
    • /
    • 2004
  • PET/CT combines the functional information from a positron emission tomography (PET) exam with the anatomical information from a computed tomography (CT) exam into one single exam. A CT scan uses a combination of x-rays and computers to give the radiologist a non-invasive way to see inside your body. One advantage of CT is its ability to rapidly acquire two-dimensional pictures of your anatomy. Using a computer these 2-D images can be presented in 3-D for in-depth clinical evaluation. A PET scan detects changes in the cellular function - how your cells are utilizing nutrients like sugar and oxygen. Since these functional changes take place before physical changes occur, PET can provide information that enables your physician to make an early diagnosis. The PET exam pinpoints metabolic activity in cells and the CT exam provides an anatomical reference. When these two scans are fused together, your physician can view metabolic changes in the proper anatomical context of your body. PET/CT offers significant advantages including more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake, and improvements in monitoring treatment. A PET/CT scan allows physicians to measure the body's abnormal molecular cell activity to detect cancer (such as breast cancer, lung cancer, colorectal cancer, lymphoma, melanoma and other skin cancers), brain disorders (such as Alzheimer's disease, Parkinson's disease, and epilepsy), and heart disease (such as coronary artery disease).

  • PDF

A Case of Pulmonary Lymphangioleiomyomatosis (폐의 임파관 평활근종증 1예)

  • Kang, Sung-Yi;Yoon, Ki-Heon;Yoo, Jee-Hong;Kang, Hong-Mo;Yang, Moon-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.3
    • /
    • pp.266-270
    • /
    • 1992
  • Pulmonary lymphangioleiomyomatosis is a rare disease, prevalent in women of reproductive age, and characterized by proliferation of atypical smooth muscle in the lung. A 44-year-old women with pulmonary lymphangioleiomyomatosis was presented. Chest radiographs showed diffuse increased reticulonoular infiltrations on the almost entire lung and high resolution CT illustrated multiple, well defined cystic lesions which were distributed diffusely through the lung. Histologic confirmation of lymphangioleiomyomatosis was made upon open lung biopsy. Treatment with methylprogesterone was initated.

  • PDF