• 제목/요약/키워드: Luminous Environment

Search Result 81, Processing Time 0.028 seconds

Projecting Performance of a Daylighting Source Based on Its Architectura Applications in the Open-Top Surface Structure (고심도 공간의 건축적 특성에 따른 자연집광 시스템의 조명원적 성능분석)

  • Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A lightcourt design is typically used to address issues concerning aesthetics, feeling, and mood. From the view point of environmental aspect, as an ecological shaft space, it plays a key role in controlling inner quality. In particularly, the lightcourt concept allows the exploitation of daylighting by bring natural light into the center of the building, thus eliminating dark deep spaces. Additionally, the lightcourt shades the inner space in summer. The amount of light available at the base of the lightcourt depends on a number of factors; translucency of the top, reflectance and the geometry of the space. In this paper is to exemplify a lightcourt configuration with a sloped wall. It promises the maximized a sense of freedom and daylighting availability. It is a matter of course that the lightcourt with open-top plays a role as a light source for the adjacent space to the lightcourt. A series of lighting simulation provides performance data of daylighting with changing photometric factors. For the case that a skylight is not available, an electric lighting design with metal halide lamps has been established to create luminous ceiling. As expected, a sloped lightcourt with open-top exposes its superiority of daylighting source. Ancillary considerations to enhance of daylighting potential for the adjacent space have been issued with performance data.

Bio Toxicity Assessment and Kinetic Model of 6 Heavy Metals Using Luminous Bacteria (발광미생물을 이용한 중금속 6종의 생물독성 평가 및 모델링)

  • Kim, Ilho;Lee, Jaiyeop
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.547-555
    • /
    • 2018
  • In addition to North America and Europe, Korea is also responding to the toxic damage caused by the production and distribution of chemicals. Methods for assessing bio-toxicity of harmful substances have been widely introduced, but it is required of quantitative and speedy information for modeling. For 6 heavy metals, as zinc, copper, chrome, cadmium, mercury and lead, bio-toxicity assessment and kinetics model were constructed using Vibrio fischeri which is widely used luminous bacteria. The degree of luminescence activity and the toxicity of heavy metals were relative limunescence unit, RLU measured as by using a photomultiplier embedded device. The toxicity was assessed by the concentration levels giving under 20% lethality and lethal concentration, $EC_{50}$. In the results, the toxicity order were followed from mercury, lead, copper, chrome, zinc and cadmium. $EC_{{50},{\infty}}$ obtained by trends of $EC_{50}$ by time follows had highly linear agreement with main parameters of bio-toxicity modelling. The average error rates of the reproduced lethality obtained from DAM and TDM model on the basis of body residue, were 10.2% for mercury, lead, copper, chrome and 20.0 for the all 6 methals.

The Effect of Atrium on Energy Conservation and Environmental Control of a Building (아트리움의 에너지 절약(節約)과 환경조절기능(環境調節機能)에 관한 연구(硏究))

  • Lee, Eon-Gu;Lee, Hyeon-Ho
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.5-11
    • /
    • 1993
  • The study, considering the fact that most of the recently built atrium buildings do not fulfill their capacity of energy conservation and environmental control, aims to develop design strategies for architects in designing atrium buildings in terms of energy/environment standpoint. The research includes case studies of existing atrium buildings, quantatative analysis of energy performance for atrium buildings and systematic investigation of various aspects of atrium regarding its function of thermal, luminous and acoustical control of a building. The result of the study may contribute to the considerable reduction of energy consumption as well as to improvement of overall building environment.

  • PDF

A Study on Integration of Pre-manufactured Window Systems with Conventional Building Design Elements (자연채광 요소기술 도출을 위한 창호시스템과 건물요소와의 통합화에 관한 연구)

  • Kim, Jeong-Tai;Jeong, In-Young;Jeong, Yu-Gun
    • KIEAE Journal
    • /
    • v.2 no.2
    • /
    • pp.15-22
    • /
    • 2002
  • Importation of mass production of building elements with standardization are vital way for environment-friendly architectural planning, which it makes the lifespan of a building longer than normal with easier maintenance and remodeling. The advantage might be magnified here in Korea since typical types of apartment house are dominated in our construction market. For the purpose, a series of pre-manufactured window systems is one of the optimal elements to be prototype building modules. In the design process of the system windows, lots of consideration should be involved and they include aesthetics, thermal performance, noise reduction, airtightness, and so forth. A real survey on the ready-made window systems has been performed and its optical issue related to luminous peculiarity is what is of major interest in this study. In addition, technical review on more advanced window products and their adaptable potential for the integration with fundamental architectural design elements were carried out.

A Study on Daylighting Performance of an Inner Court with Reflecting Mirror System (반사거울 방식을 이용한 중정 내 자연채광 성능 분석 연구)

  • Park, Byung-Yoon;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.112-121
    • /
    • 2011
  • To lead lighting inside, design solution and mechenical solution can be used.A inner court and atrium are samples for design solution. However, physical and environmental elements for building design are not taken positively into consideration. So low position of the inner court is difficult to reach lighting performance and a urban landscape gets damaged. On this study, selecting a building with a inner court, best design method is suggested to apply reflecting mirror. building direction, building shape and solar position are considered to deside the setting angle for reflecting mirror. Performance for the setting reflecting mirror is verified through various simulation cases, and is got more lighting performance than the present situation on the building inside.

Comparative Luminance and Correlated Color Temperature of Work-place by a Fluorescent and LED Light Sources (LED광원과 형광광원에 의한 작업면의 휘도 및 색온도 비교)

  • Baik, Seung heon;Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.21-26
    • /
    • 2008
  • According to the tendency of energy efficiency and environment-friendly chracteristics, demend of High-efficiency lighting using LED(Light Emitting Diode)are being increased actively and applied in various fields. However, In order to adequate application of LED light sources, it is necessary to lighting environment and luminous characteristics of LED light sources. This Study aims to characterize the work-plane lighting environment by LED light sources comparing with fluorescent light sources which are widely used. For the sake of this study, a fluorescent light source and 5 LED light sources were introduced and luminance and correlated color temperature were measured to evaluate luminance contrast. The experimental model is Mock-up which is $4.9m{\times}7.2m$ with a height of 2.9m. The test room was set up partition and desks. Luminance and correlated color temperature were measured work-plane on the desk which was set up local lighting by the Radiant Imaging ProMetric 1400. The optical characteristics data of LED can give a lot of advantages to design LED lighting appliances. Hereafter, the object of research will be conducted to evaluate effects of LED light sources on working performance, survey of visual performance, preference and physiology of subjects.

Effects of LED Lamps for Replacement of Metal Halide Lamp in Roadway Lighting Environment (LED램프와 메탈램프가 도로조명환경에 미치는 특성 비교평가)

  • Lee, Myung Gi;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.47-52
    • /
    • 2013
  • The problems of light pollution first became an issue in the 1970s when astronomers identified the degradation of the night sky due to the increase in lighting associated with development and growth. As more impacts to the environment by lighting have been identified, many attempts have been made for reducing light pollutions. To prevent light pollution and increase energy efficiency, Seoul Metropolitan Government(SMG) replaced metal halide road lighting to LED luminaire in four arterial highway in Seoul. The present study compared the lighting characteristics of metal halide and LED luminaire in terms of Korea Standard for road lighting(KS A 3701) and BUG rating from Illuminating Engineering Society of North America(IESNA). The results showed that LED luminaire increased road surface luminance up to 2 times in average compared to the metal halide environment. Also, LED luminaire reduced the glare value by 2 times and luminous flux over 50% than the metal halide luminaire. In comparison with the BUG ratings, LED luminaire rated 1 degree lower for the backlight ratings and 3-4 degrees lower for the uplight ratings. The measured values testified that the LED luminaire is effective for roadway lighting and light pollution reduction.

Analysis on the Reduction of Cooling Load and Improvement of Visual Environment by applying a Kinetic Shading Device in Summer (가변형 차양장치 적용에 따른 하절기 냉방부하 저감 및 빛환경 개선효과 분석)

  • Cha, Gi-Wook;Moon, Hyeun Jun;Kim, Ho-Jeong;Hong, Won-Hwa;Baik, Yong-Kyu
    • Journal of Korean Living Environment System
    • /
    • v.24 no.6
    • /
    • pp.810-823
    • /
    • 2017
  • The envelope is important for sustainable building. Recent commercial buildings are causing thermal degradation and cooling load due to the increase of the area of the windows. Therefore, this research studied kinetic shading system which can improve energy saving and visual environment in summer. For that, this study proposed new shading system and shape considering the orientation of the building and the location of the sun. Based on this, this study analyzed the effectiveness on energy reduction and improvement of visual environment by applying the kinetic shading system proposed in this study. As the results of this study, energy reduction rate was 35% in the east, 22.9% in the south, and 30.7% in the west depending on the application location. Also, as the result of the illuminance analysis, it was found that the effect of achieving uniformity ratio of illumination was considerable.

Study of Efficiency Test and Subjective Responses about Pendent Task Lighting System Using Phosphor Luminescent Film LED (광기여 필름 LED 팬던트 작업조명시스템 주관평가와 성능검증)

  • Cha, Kwang-Seok;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.188-193
    • /
    • 2011
  • For a long time work or study, pendent task lighting system prepared with phosphor luminescent film LED was developed for eye protection and working efficiency improvement. Developed lighting system was used together with pendent and ambient lighting. Such as, we made comfortable lighting environment system. Evaluation for developed lighting system, that had proceeded to Mock-up test and subjective evaluation. Also It had proceeded that lighting environment analyzed and compatibility valuation of installation. In subjective evaluation, the students have expressed themselves satisfied to phosphor luminescent film LED lighting system. In Mock-up test, It is not problem to intensity of illumination, luminance and color temperature. Therefore, developed LED lighting system was installed at the Daegu apartment. It is having a P.O.E study progress to phosphor luminescent film LED lighting system.

Study on Sensitivity of Variables of the Experiment to Evaluate Discomfort Glare of Interior Artificial Illumination (건축실내 인공조명의 불쾌글레어 평가실험에 적용된 실험변수의 민감도 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Chang-Soon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.24-32
    • /
    • 2008
  • The ultimate purpose of the study is to develop a discomfort glare forecasting formula that can be practically used in Korea in order to effectively forecast discomfort glare considering the optical characteristics of the Koreans. The study was to examine the relations between discomfort glare and the variables such as luminance, background luminance, solid angle, luminous area and louver. To this end, experiments were conducted in a mock-up office that emulates the lighting environment of an ordinary office. The study was conducted by four steps as follow. First, previous studies on discomfort glare rating to define and rate discomfort glare were analyzed and modified to be applied to the experiments of this study. Second, experiment variables, variable scope, evaluation objects and evaluation points were determined after review on existing discomfort glare evaluation experimental formulas. Third, experiments were conducted in a mock-up office to be able to control variables. Finally, sensitivity of experiment variables were analyzed through examination of the relation between discomfort glare and the variables such as luminance, solid angle, louver, luminous area and subject's position. The result showed that the most influential variables on discomfort glare of an artificial light source is luminance and louver, luminous area and subject's position(solid angle) followed.