저압 전기설비의 과전압 억제 필요성 판단 (Judgement of the need for Over-Voltage Control of the Low-Voltage Electrical Installations)

  • 이주철;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.91-96
    • /
    • 2015
  • There are provision for risk analysis in IEC standards. It is to determine the need for installation of a surge protection device (SPD) in order to protect the low-voltage electrical installations from overvoltages caused by atmospheric phenomena and the like. However, scattered many related standards, the lack of details are not easy to apply it in the field. We investigated the relevant domestic and international standards for applies to the international standards in domestic. And we proposed the flow chart for determining the need for protection of the low-voltage electrical installations from overvoltage due to atmospheric phenomena and it set the appling target facility.

저압수용가에 공급하는 TT, TN계통의 뇌서지에 대한 보호성능의 평가 (Evaluation of the Protection Performance of TT and TN Systems for Low-Voltage Consumers Against Lightning Surges)

  • 이규선;최종혁;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.67-74
    • /
    • 2010
  • 국내의 저압수용가 대부분은 한국전력공사의 TN-C접지방식으로부터 공급받고 있으나 부하설비는 TT 접지방식을 위주로 한 전기설비기술기준에 따라 시설되어 있다. 본 연구에서는 정보기술설비를 뇌서지로부터 보호할 수 있는 적절한 전원계통접지방식을 제안하기 위해서 TT, TN계통의 뇌서지에 대한 보호성능을 연구하였다. 그 결과, 뇌서지가 배전계통의 중성선에 입사한 때 TT계통의 기기접지단자와 전원선의 중성점 사이에 높은 전위차가 발생하였으며, 예민한 컴퓨터설비가 손상될 위험성이 있으므로 TT계통은 적합하지 않다. 뇌서지로부터 저압 설비를 보호하기 위해서는 등전위본딩이 중요한 요건이며, TN계통이 중성선을 통하여 입사하는 뇌서지의 저감에 가장 우수하였으며, 수용가 인입구에서의 추가접지도 바람직한 방법이다.

저압 수용가 설비에서 누전차단기와 서지방호장치 사이의 보호협조 (Protection coordination between residual current device and surge protective devices in low-voltage consumer's installations)

  • 이복희;김회구;박희열;안창환
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.75-81
    • /
    • 2013
  • In this paper, protection coordination between residual current devices and surge protective devices in low-voltage consumer's distribution systems are presented. In the case that a surge protrctive device(SPD) is located on the load side of an residual current device(RCD), when the surge is injected from the source side of the RCD, most of injected surge currents are split into the RCD and the protection coordination between the SPD and RCD is improper, three of 6 specimens experience unintended operation due to test impulse currents. Also when the surges is injected from the load side, a lot of the surge currents is split into the SPD, but a half of test specimens causes nuisance trip. Coordination between SPD and RCD is not valid. When installing SPD, it is important to select SPD after due consideration of the protection voltage level of metal oxide varistor embedded in RCD. It is expected that the results obtained from this work could be useful to improve the protection effects of SPD in low-voltage distribution systems.

22.9 kV-Y 계통에서 지락고장이 인체 및 저압설비의 안전에 미치는 영향 (Effects of Ground Faults on the Safety of Persons and Low-voltage Installations in 22.9 kV-Y Distribution Systems)

  • 김한수;정재희;강계명
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.141-148
    • /
    • 2008
  • 본 논문에는 22.9 kV-Y 배전계통의 1선 지락고장이 인체의 안전 및 저압설비의 보호에 대한 실험적 결과를 기술하였다. 새로이 제정된 KS C IEC 60364 규격군에 따른 고압 충전도체가 대지에 접촉되는 지락고장에 의한 위험전압과 저압기기의 스트레스전압을 평가하기 위해서 22.9[kV] 중성점 다중접지계통에 대한 실증실험을 수행하였다. 실험결과로부터 KS C IEC 60364 규격군을 기존의 국내배전계통에 적용할 때 부합되지 않는 중대한 문제점을 도출하였으며, 22.9 kV-Y 다중접지와 수용가설비접지를 공용하는 공통접지계통에서 발생하는 지락고장에 의한 일시적 과전압에 대한 효과적인 보호대책을 제시하였다. 결국 22.9 kV-Y계통과 저압설비를 공통접지로 하는 경우 인체와 저압설비의 안전을 위한 효과적인 보호대책의 구현에는 등전위본딩이 중요한 필수적 요건임이 밝혀졌다.

방전전극 재질과 최소점화에너지에 관한 실험 연구 (An Experimental Study on the Minimum Ignition Energy in Low Voltage Spark Discharge by Electrode Material)

  • 최상원
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.63-70
    • /
    • 2012
  • In the hazardous areas where explosive gases, vapor or mists exist, electrical apparatus and installations must be the explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, nine types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, non-incendive, powder filling, encapsulation, and special types. Among these types, the intrinsic safety has the construction which limit or by-pass igniting the electric energy using electronic devices. This type has lots of merits but at the same time requires a high-degree of technology. In this paper, we investigated several dominating factors which affect the minimum ignition energy; this energy plays a very important role in design and evaluation of the intrinsic safety type electrical apparatus. Electrode material, which is one of the most important factors, was intensively studied for the five sorts of material(Al, Cd, Mg, Sn, and Zn) with performing experiment in a low-voltage inductive circuit using IEC-type(International Electro-technical Commission) spark apparatus. The experimental results show that the minimum ignition energy of electrode material is varied: highest in Cd and lowest in Sn. We also confirmed the effect of electrode make-and-break speed.

IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험 (Field Test on IEC60364-4-44 for the Application in Korean distribution system)

  • 남기영;최상봉;정성환;이재덕;류희석;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

저압방전 불꽃에서 전극재질이 점화에너지에 미치는 영향 (Effect of Electrode Material on the Minimum Ignition Energy in Low-Voltage Spark Discharge)

  • 최상원;이관형;문정기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1394-1397
    • /
    • 1995
  • In the hazardous areas where explosive gases, vapor or mists exist, electrical apparatus and installations must be of explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, nine types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, non-incendive, sand filling, encapsulation, and special types. Among these types, the intrinsic safety has the construction which limit or by-pass igniting the electric energy using electronic devices. This type has lots of merits but at the same time requires a high-degree of technology. In this paper, we investigated several dominating factors which affect the minimum ignition energy: this energy plays a very important role in design and evaluation of the intrinsic safety type electrical apparatus. Eletrode material, which is one of the most important factors, was intensively studied for the five sorts of material(Al, Cd, Mg, Sn, and Zn) with performing experiment in a low-voltage inductive circuit using IEC-type spark apparatus. The experimental results show that the minimum ignition energy of electrode material is varied: highest in Cd and lowest in Sn. We also confirmed the effect of eletrode make-and-break speed and magnetic field magnitude.

  • PDF

EMC를 고려한 ICT배선과 전력배선 이격거리 기준의 비교검토 및 산정방식 (Comparison and Calculation Method on the Separation Between ICT and Power Cabling Considering EMC)

  • 염진근;정승현;변철균;이주철
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.91-96
    • /
    • 2014
  • The requirements for separation between ICT cables and power cables depend upon the electromagnetic immunity of the ICT cable, the construction of the power cable, the quantity of, and type of electrical circuits and the presence of dividers etc. We studied and reviewed the regulations and standards relevant for requirements of this separation in domestic and foreign. And then we would like to suggest the method of separation calculation between ICT and power cabling taking the EMC into consideration.

배전피뢰기용 접지도선의 효과적인 설치기법 (Effective Installations Technique of Grounding Conductors for Metal Oxide Surge Arrestors)

  • 이복희;강성만;유인선
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.253-259
    • /
    • 2002
  • This paper deals with the effects of grounding conductors for metal oxide surge arresters. When surge arresters are improperly installed, the results can cause costly damage of electrical equipments. In particular, the route of surge arrester connection is very important because bends and links of leads increase the impedances to lightning surges and tend to nullify the effectiveness of a grounding conductor. Therefore, there is a need to know how effective installation of lightning surge arresters is made in order to control voltage and to absorb energy at high lightning currents. The effectiveness of a grounding conductor and 18 [㎸] metal oxide distribution line arresters was experimentally investigated under the lightning and oscillatory impulse voltages. Thus, the results are as follows; (1) The induced voltage of a grounding conductor is drastically not affected by length of a connecting line, but it is very sensitive to types of grounding conductor. (2) The coaxial cable having a low characteristic impedance is suitable as a grounding conductor. (3) It is also clear from these results that bonding the metal raceway enclosing the grounding conductor to the grounding electrode is very effective because of skin effect. (4) The induced voltages of grounding conductors for the oscillatory impulse voltages are approximately twice as large as those for the lightning impulse voltages.

IEC 60364-4-44의 국내 도입을 위한 실증시험장 구성 (Configuration of Test Field for Introduction of IEC 60364-4-44 to Domestic System)

  • 남기영;최상봉;정성환;이재덕;류희석;김대경;정동학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.731-732
    • /
    • 2007
  • This paper presents the final configuration of test field and test items for the application of IEC 60364-4-44 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, domestic electric power distribution system is based on multi-grounding system different from European system. Therefore, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a national standard. The authors with KEA(Korea Electric Association) carried out a project on the application of IEC 60364-4-44 to Korean electrical installations of buildings sponsored by Korean ministry of commerce, industry and energy for three years(2004.4.1$\sim$2007.3.31). The test field is established in K.E.R.I.(Korea Electrotechnology Research Institute), which is the purpose of evaluating the formula to calculate touch voltage and stress voltage in the IEC standards. This paper presents some considerations and final configuration of test field to evaluate and introduce the IEC 60364-4-44 applicable to domestic rule for the protection against ground fault.

  • PDF