• Title/Summary/Keyword: Low Vision

Search Result 701, Processing Time 0.031 seconds

The Effects of the Relative Legibility of Optotypes on Corrected Visual Acuity (시표의 유형에 따른 상대가독성이 교정시력에 미치는 영향)

  • Ha, Na-Ri;Choi, Jang-Ho;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.177-186
    • /
    • 2015
  • Purpose: The Purpose of this study is to investigate if the relative legibility of optotypes affects the corrected visual acuity in visual acuity test. Methods: After measuring the relative legibility of 'Landolt ring target', 'arabic number target', 'alphabet target' by showing as a single-letter-target in 24 subjects without specific ocular diseases and ocular surgery experience, the relative legibility of 0.8, 1.0, 1.25 row of vision according to type of target in 7 types of chart were compared. After then we compared by measuring the corrected visual acuity according to type of target by using binocular MPMVA test (#7A) in 60 myopic subjects. Results: In 3 types of target the worst relative legibility target was 'Landolt ring target' with legible distance of $98.97{\pm}4.57cm$ and the best relative legibility target was 'alphabet target' with legible distance of $108.42{\pm}3.46cm$. There was no difference of the relative legibility according to type of chart or visual acuity level in the row of vision if other conditions are the same. In 1.0 and 1.25 row of vision the difference of relative legibility according to type of target was shown the statistically significant difference between 'Landolt ring target' and 'alphabet target' as $-0.07{\pm}0.06$ (p=0.02) and $-0.06{\pm}0.06$ (p=0.04) respectively. In myopia the difference of corrected visual acuity according to type of target was statistically significant difference between 'Landolt ring target' and 'arabic number target' as $-0.04{\pm}0.02$ (p=0.02) and it was especially remarkable in the low myopia. Conclusions: Measuring visual acuity with different optotypes could cause the errors in best vision measurement value because there was difference of the relative legibility according to type of target even though visual acuity level is same in the row of vision.

A Relationship between Kinetic Visual Acuity and Contrast Sensitivity (동적시력과 대비감도의 상관관계)

  • Shim, Moon-Sik;Kang, Hye-Sook;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.225-229
    • /
    • 2014
  • Purpose: The study was to analyze the correlation between kinetic visual acuity (KVA), visual acuity(static visual angle, SVA) and contrast sensitivity. Methods: Ninety-nine undergraduate students studying Ophthalmic Optics were fully corrected by the Topcon CV-3000 Phoropter. The contrast sensitivity was measured for the participants under the photopic condition ($100cd/m^2$) with Vector Vision CSV-1000E at 2.5 meter, while KVA was measured with KOWA AS-4A. The participants were classified into three groups L, M and H depending on the KVA (0.1~0.3, 0.31~0.6 and greater than 0.61, respectively) and were analyzed whether there was the correlation between the contrast sensitivity, visual acuity and refractive error. Results: The KVA was correlated with the contrast sensitivity for 3 cpd (r=0.26), for 6 cpd (r=0.48), for 12 cpd (r=0.38) and 18 cpd (r=0.47). Except for the low frequency of 3 cpd, they all were higher than the one of the SVA and the KVA (r = -0.37). The contrast sensitivity for 3, 6, 12 and 18 cpd was 59.41, 92.22, 38.41 and 14.39 in the group L, respectively. The contrast sensitivity in the group M was 66.03, 108.78, 53.51 and 19.20 and the one in the group H was 70.90, 146.10, 62.90 and 25.33 for 3, 6, 12 and 18 cpd, respectively. Conclusions: The correlation of the contrast sensitivity and the KVA was higher than the one of the contrast sensitivity and the SVA. It can be assumed that the contrast sensitivity will be high if the KVA is high, except for the case for low spatial frequency.

Autonomous Surveillance-tracking System for Workers Monitoring (작업자 모니터링을 위한 자동 감시추적 시스템)

  • Ko, Jung-Hwan;Lee, Jung-Suk;An, Young-Hwan
    • 전자공학회논문지 IE
    • /
    • v.47 no.2
    • /
    • pp.38-46
    • /
    • 2010
  • In this paper, an autonomous surveillance-tracking system for Workers monitoring basing on the stereo vision scheme is proposed. That is, analysing the characteristics of the cross-axis camera system through some experiments, a optimized stereo vision system is constructed and using this system an intelligent worker surveillance-tracking system is implemented, in which a target worker moving through the environments can be detected and tracked, and its resultant stereo location coordinates and moving trajectory in the world space also can be extracted. From some experiments on moving target surveillance-tracking, it is analyzed that the target's center location after being tracked is kept to be very low error ratio of 1.82%, 1.11% on average in the horizontal and vertical directions, respectively. And, the error ratio between the calculation and measurement values of the 3D location coordinates of the target person is found to be very low value of 2.5% for the test scenario on average. Accordingly, in this paper, a possibility of practical implementation of the intelligent stereo surveillance system for real-time tracking of a target worker moving through the environments and robust detection of the target's 3D location coordinates and moving trajectory in the real world is finally suggested.

Color Vision Based Close Leading Vehicle Tracking in Stop-and-Go Traffic Condition (저속주행환경에서 컬러비전 기반의 근거리 전방차량추적)

  • Rho, Kwang-Hyun;Han, Min-Hong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.9
    • /
    • pp.3037-3047
    • /
    • 2000
  • This paper describes a method of tracking a close leading vehicle by color image processing using the pairs of tail and brake lights. which emit red light and are housed on the rear of the vehicle in stop-and-go traffic condition. In the color image converted as an HSV color model. candidate regions of rear lights are identified using the color features of a pair of lights. Then. the pair of tailor brake lights are detected by means of the geometrical features and location features for the pattern of the tail and brake lights. The location of the leading vehicle can be estimated by the location of the detected lights and the vehicle can be tracked continuously. It is also possible to detect the braking status of the leading vehicle by measuring the change in HSV color components of the pair of lights detected. In the experiment. this method tracked a leading vehicle successfully from urban road images and was more useful at night than in the daylight. The KAV-Ill (Korea Autonomous Vehicle- Ill) equipped with a color vision system implementing this algorithm was able to follow a leading vehicle autonomously at speeds of up to 15km!h on a paved road at night. This method might be useful for developing an LSA (Low Speed Automation) system that can relieve driver's stress in the stop-and-go traffic conditions encountered on urban roads.

  • PDF

Color Restoration Method Using the Dichromatic Reflection Model for Low-light-level Environments (저조도 환경에 적합한 이색도 반사 모델을 이용한 색 복원 기법)

  • Lee, Woo-Ram;Jun, WooKyoung;Jun, Byoung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7324-7330
    • /
    • 2014
  • Color distortion of the dark images acquired under a low-light-level environment with a weak light source can be cause of the performance decreation of various vision systems. Therefore, recovering the original color of the images is an important process for enhancing the performance of the system. For this, this study proposes a color restoration method using a dichromatic reflection model. This paper assumes that the dark images can be classified into two parts affected by specular or diffuse reflection. Two different color constancy methods were then applied to the images to remove the effects of each reflection and two images were created as a result. The resulting images produced a one color-corrected image by combining with different weights according to the position in the images. For the performance evaluation, this paper used a synthesized image, and considered the Euclidean distance and angular error as an evaluation factor. In addition, a performance comparison was performed with the existing various color constancy method to achieve the objectivity of evaluation. The experimental results showed that the proposed method can be a more suitable solution for color restoration than the existing method.

A Mobile Newspaper Application Interface to Enhance Information Accessibility of the Visually Impaired (시각장애인의 정보 접근성 향상을 위한 모바일 신문 어플리케이션 인터페이스)

  • Lee, Seung Hwan;Hong, Seong Ho;Ko, Seung Hee;Choi, Hee Yeon;Hwang, Sung Soo
    • Journal of the HCI Society of Korea
    • /
    • v.11 no.3
    • /
    • pp.5-12
    • /
    • 2016
  • The number of visually-impaired people using a smartphone is currently increasing with the help Text-to-Speech(TTS). TTS converts text data in a mobile application into sound data, and it only allows sequential search. For this reason, the location of buttons and contents inside an application should be determined carefully. However, little attention has been made on TTS service environment during the development of mobile newspaper application. This makes visually-impaired people difficult to use these applications. Furthermore, a mobile application interface which also reflects the desire of the low vision is necessary. Therefore, this paper presents a mobile newspaper interface which considers the accessibility and the desire of various visually impaired people. To this end, the proposed interface locates buttons with the consideration of TTS service environment and provides search functionality. The proposed interface also enables visually impaired people to use the application smoothly by filtering out the words that are pronounced improperly and providing the proper explanation for every button. Finally, several functionalities such as increasing font size and color reversal are implemented for the low vision. Simulation results show that the proposed interface achieves better performance than other applications in terms of search speed and usability.

Change of Corneal Shape with Soft Contact Lens Type (소프트콘택트렌즈의 유형에 따른 각막형태의 변화)

  • Woo, Chul-Min;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2014
  • Purpose: This study was to investigate changes in the thickness of cornea, curvature of cornea, and aberration depending on the water contents, materials, and refractive power of contact lens. Methods: The differences in the corneal thickness between pre- and post-wearing the lenses were compared using 5 kinds of lenses. The changes in the corneal thickness, the curvatures of the anterior and posterior cornea, and high order aberration (HOA) before and after wearing the lenses were investigated at the center of the cornea, and the different distance and the direction away from the center of the cornea. For the equipments of measurement, ORB ScanII (Bausch & Lomb Inc, ver 3.14) was used to measure the corneal topography and thickness, and Zywave (Bausch & Lomb Inc, ver 5.20) was used to analyze the high order aberration. Results: Five (S1, S2, S3, T1, T2) of the lens was used for this study, excluding the lens T2 lens has four lenses and the thickness of the corneal shape, but the impact is minimal. In the case of the hydrogel soft contact lenses (T2 lens) with low oxygen permeability, the corneal thickness showed distinct increasing patterns. The high order aberration and coma aberration were most changed in the silicon hydrogel toric lens, while the depth of anterior was most changed in the hydrogel toric lens. Conclusion: Among the 5 kinds of contact lenses with different water contents, materials, and refractive power used for this study, the corneal shape change was small for the lenses with an oxygen permeability (Dk) of more than 28, and the largest for the lenses with a very low oxygen permeability.

Accuracy of Parcel Boundary Demarcation in Agricultural Area Using UAV-Photogrammetry (무인 항공사진측량에 의한 농경지 필지 경계설정 정확도)

  • Sung, Sang Min;Lee, Jae One
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.1
    • /
    • pp.53-62
    • /
    • 2016
  • In recent years, UAV Photogrammetry based on an ultra-light UAS(Unmanned Aerial System) installed with a low-cost compact navigation device and a camera has attracted great attention through fast and accurate acquirement of geo-spatial data. In particular, UAV Photogrammetry do gradually replace the traditional aerial photogrammetry because it is able to produce DEMs(Digital Elevation Models) and Orthophotos rapidly owing to large amounts of high resolution image collection by a low-cost camera and image processing software combined with computer vision technique. With these advantages, UAV-Photogrammetry has therefore been applying to a large scale mapping and cadastral surveying that require accurate position information. This paper presents experimental results of an accuracy performance test with images of 4cm GSD from a fixed wing UAS to demarcate parcel boundaries in agricultural area. Consequently, the accuracy of boundary point extracted from UAS orthoimage has shown less than 8cm compared with that of terrestrial cadastral surveying. This means that UAV images satisfy the tolerance limit of distance error in cadastral surveying for the scale of 1: 500. And also, the area deviation is negligible small, about 0.2%(3.3m2), against true area of 1,969m2 by cadastral surveying. UAV-Photogrammetry is therefore as a promising technology to demarcate parcel boundaries.

The effect of change of mandatory referral system in an ophthalmology of tertiary care medical institution (의료전달체계 변경이 3차 의료기관 안과에 미친 영향)

  • Kim, Yang-Soo;Yu, Seung-Hum;Oh, Hyohn-Joo;Kwon, Oh-Whoong
    • Korea Journal of Hospital Management
    • /
    • v.7 no.1
    • /
    • pp.88-104
    • /
    • 2002
  • According to the change of mandatory referral system in July 1, 2000, the effect to the medical utilization of outpatient clinic and medical income in ophthalmology of tertiary care medical institute, S Hospital in Seoul was evaluated for 6 months before(1999. 12$\sim$2000. 5) and after(2000. 12$\sim$2001. 5). The results were as follows: 1. The number of outpatients was reduced by 16.6%. The number of patient with blindness low vision, retina, glaucoma increased and that of patient with accommodation refractive error, cataract decreased. 2. The number of cataract patients was reduced by 36.6%. The major location of patient's address was changed to nearer to the hospital. The number of cataract surgery reduced in 4.1%, the waiting time reduced in 42.2%, however surgery time increased in 20.2% and number of postoperative complications increased in 11.4%. 3. The income of outpatient clinic and cataract surgery reduced. Among items of outpatient clinic income, the most increased was ocular examination and the most reduced was injection and drugs. Among items of cataract surgery income, the most increased was operation fee and the most decreased was doctor's fee. In conclusion, for the patient, due to the lowered density of outpatient population more space was provided to the patients with more severe disease entity such as blindness' low vision, retina and glaucoma. For the hospital, the need for the expansion of ophthalmology was not found, however that for creation of the special clinics dealing with more severe disease entity was found. Due to reduced income and increased need of financial investment for the equipment and manpower for the more severe disease entity, the ophthalmology of tertiary care medical institute is faced with financial disaster. It is strongly suggested that the cost of medical practice of more severe disease entity be raised to achieve the success after change of mandatory referral system in ophthalmology.

  • PDF

Comparison of Play Ability of Soccer Fields with Natural Turfgrass, Artificial Turf and Bare Ground (천연잔디, 인조잔디 및 맨땅 축구장에서 축구 경기력 비교)

  • Lee, Jae-Pil;Park, Hyun-Chul;Kim, Doo-Hwan
    • Asian Journal of Turfgrass Science
    • /
    • v.20 no.2
    • /
    • pp.203-211
    • /
    • 2006
  • This study was initiated to investigate the difference of playing ability among soccer fields established with natural turfgrass, artificial turf and bare ground. The soccer fields with natural turfgrasses were established with cool-season grass(Kentucky bluegrass 80%+Perennial ryegrass 20%) and zoysiagrass. The artificial turf field was constructed with Konigreen $DV5000^{TM}$. Bare ground was sandy soil. Data such as ball rolling distance and vertical ball rebound were collected at the Sports Science Town of Konkuk University from 2005 to 2006. A ball in the study was Hummel Air Vision #1, certified by KFA(Korea Football Association) in ball pressure of 1.01b. Ball rolling distance was the longest on bare ground(13.6m), followed by artificial grass(11.4m), cool-season grass(7.8m) and zoysiagrass(4.7m). It decreased with lower frequency in use, stronger rigidity and higher density of turfgrass. Vertical ball rebound was the highest on bare ground(1.0m), followed by artificial grass(0.9m), cool-season grass(0.6m) and zoysiagrass(0.4m). It was lower under conditions of low use frequency, strong rigidity, and high density. Both ball rolling distance and vertical ball rebound were not greatly affected by cool-season grass maintained with high intensity of culture by years after establishment. However, zoysiagrass field under low intensity of culture showed longer in ball rolling distance and higher in vertical ball rebound with time after establishment.