DOI QR코드

DOI QR Code

A Relationship between Kinetic Visual Acuity and Contrast Sensitivity

동적시력과 대비감도의 상관관계

  • Shim, Moon-Sik (Dept. of Ophthalmic Optics, Gwangju Health University) ;
  • Kang, Hye-Sook (Dept. of Ophthalmic Optics, Gwangju Health University) ;
  • Kim, Sang-Hyun (Dept. of Ophthalmic Optics, Gwangju Health University) ;
  • Shim, Hyun-Suk (Dept. of Ophthalmic Optics, Gwangju Health University)
  • 심문식 (광주보건대학교 안경광학과) ;
  • 강혜숙 (광주보건대학교 안경광학과) ;
  • 김상현 (광주보건대학교 안경광학과) ;
  • 심현석 (광주보건대학교 안경광학과)
  • Received : 2014.04.29
  • Accepted : 2014.06.18
  • Published : 2014.06.30

Abstract

Purpose: The study was to analyze the correlation between kinetic visual acuity (KVA), visual acuity(static visual angle, SVA) and contrast sensitivity. Methods: Ninety-nine undergraduate students studying Ophthalmic Optics were fully corrected by the Topcon CV-3000 Phoropter. The contrast sensitivity was measured for the participants under the photopic condition ($100cd/m^2$) with Vector Vision CSV-1000E at 2.5 meter, while KVA was measured with KOWA AS-4A. The participants were classified into three groups L, M and H depending on the KVA (0.1~0.3, 0.31~0.6 and greater than 0.61, respectively) and were analyzed whether there was the correlation between the contrast sensitivity, visual acuity and refractive error. Results: The KVA was correlated with the contrast sensitivity for 3 cpd (r=0.26), for 6 cpd (r=0.48), for 12 cpd (r=0.38) and 18 cpd (r=0.47). Except for the low frequency of 3 cpd, they all were higher than the one of the SVA and the KVA (r = -0.37). The contrast sensitivity for 3, 6, 12 and 18 cpd was 59.41, 92.22, 38.41 and 14.39 in the group L, respectively. The contrast sensitivity in the group M was 66.03, 108.78, 53.51 and 19.20 and the one in the group H was 70.90, 146.10, 62.90 and 25.33 for 3, 6, 12 and 18 cpd, respectively. Conclusions: The correlation of the contrast sensitivity and the KVA was higher than the one of the contrast sensitivity and the SVA. It can be assumed that the contrast sensitivity will be high if the KVA is high, except for the case for low spatial frequency.

목적: 동적시력(Kinetic visual acuity, KVA), 대비감도(Contrast sensitivity), 정지시력(정지시각 Static visual angle, SVA) 등의 상관관계를 분석해 보고자 하였다. 방법: 안경광학과 재학생 99명(남 51명, 여 48명)을 대상으로 Topcon CV-3000 포롭터를 이용하여 완전교정 후 명소시($100cd/m^2$)상태에서 Vector Vision CSV-1000E를 이용하여 2.5 m 거리에서 대비감도를 측정하였다. 또한 KVA 측정장치(KOWA AS-4A)을 이용하여 동적시력을 측정하였다. KVA 정도에 따라, 0.1~0.3 L그룹, 0.31~0.60 M그룹, 0.61 이상을 H그룹으로 분류하고 대비감도, 정지시각, 굴절이상량 등의 상관관계를 분석하였다. 결과: KVA와 대비감도의 상관성은 3 cpd r=0.26, 6 cpd r = 0.48, 12 cpd r=0.38, 18 cpd r=0.47로 저주파수인 3 cpd를 제외하고, 모두 KVA와 SVA의 상관성 r = -0.37 보다 높았다. 주파수별 대비감도는 3, 6, 12, 18 cpd에서 각각 L그룹은 59.41, 92.22, 38.41, 14.39, M그룹은 66.03, 108.78, 53.51, 19.20, H그룹은 70.90, 146.10, 62.90, 25.33이였다. 결론: KVA와 대비감도의 상관성이 SVA보다 높으며, KVA가 높은 경우 저주파수 이외에서는 대체로 대비감도가 높은 것을 알 수 있었다.

Keywords

References

  1. Won CH, Mah KC. Sports vision training, 1st Ed. Seoul: Daehakselim, 1993;23-24.
  2. Campbell FW, Green DG. Optical and retinal factors affecting visual resolution. J Physiol. 1965;181(3):576-593. https://doi.org/10.1113/jphysiol.1965.sp007784
  3. Atchison DA, Smoth G, Efron N. The effect of pupil size on visual acuity in uncorrected and corrected myopia. Am J Optom Physiol Opt. 1979;56(5):315-323. https://doi.org/10.1097/00006324-197905000-00006
  4. Jindra LF, Zenmon V. Contrast sensitivity testing: A more complete assessment of vision. J Cataract Refract Surg. 1989;15:141-148. https://doi.org/10.1016/S0886-3350(89)80002-1
  5. Samuel Masket. Atlas of cataract surgery, 1st Ed. Los Angeles: Martin Dunitz, 1999;3-5.
  6. Shim MS, Kim SH, Kang HS, Shim HS. The study of kinetic visual acuity in college students. J Korean Oph Opt Soc. 2012;17(4):419-424.
  7. Shim HS, Kim SH, Kang HS. Changes in KVA resulting from correction condition of refractive error. J Korean Oph Opt Soc. 2013;18(2):165-171.
  8. Choi SL, Han KL, Shim HS. Comparison to contrast sensitivity of male and female adults in their 20s. J Korean Oph Opt Soc. 2014;19(1):87-92. https://doi.org/10.14479/jkoos.2014.19.1.87
  9. You YC, Choi TH, Lee HB. Normal contrast sensitivity for various ages. J Korean Ophthalmol Soc. 2003;44(1):150-156.
  10. Seo JM. Analysis of the visual function in low vision patients and normals in Canada, using contrast sensitivity. J Korean Oph Opt Soc. 2009;14(3):83-88.
  11. Ahn BC. Dynamic and kinetic visual acuity of athletes and nonathletes. J Korean Sports Med. 1998;16(2):238-244.
  12. Kakiyama T, Kushima A, Hirota A. Effects of the correction of visual acuity on kinetic visual acuity (KVA) in high school rugby players. Japanese J Physical Fitness and Sports Med. 2004;53(2):255-262.
  13. Mochizuki S, Edagawa H, Hasuike M. A study of kinetic visual acuity and refraction in athletes. J Japanese Orthopt. 1998;26:25-30.
  14. Pomerance G, Evans D. Test-retest reliability of the CSV-1000 contrast test and its relationship to glaucoma therapy. Invest Ophthalmol Vis Sci. 1994;35(9):3357-3361.

Cited by

  1. The Comparative Assessment of the KVA and Dynamic Stereoacuity vol.19, pp.4, 2014, https://doi.org/10.14479/jkoos.2014.19.4.519
  2. Comparison of Corneal Aberration and Contrast Sensitivity for WTR-Astigmatism according to the Prescription Method of Soft Contact Lenses vol.26, pp.3, 2014, https://doi.org/10.14479/jkoos.2021.26.3.181