• Title/Summary/Keyword: Loss of angle

Search Result 849, Processing Time 0.028 seconds

Some Properties on Jacobian Matrix (전력조류방정식과 자코비안 행렬의 성질에 대하여)

  • Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.251-253
    • /
    • 2004
  • Though the reference angle has been specified conventionally on the slack bus, it can be specified on my bus in the system without changing power flow solutions. This paper describes that the loss sensitivity of the salk bus can be obtained through an angle reference transposition. A concept of two reference buses, consisting of "power slack bus"

  • PDF

A novel PLL control method for robust three-phase thyristor converter under sag and notch conditions

  • Lee, Changhee;Yoo, Hyoyol
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.87-88
    • /
    • 2014
  • The paper presents a novel phase locked loop(PLL) control method for robust three-phase thyristor dual converters under sag, notch, and phase loss conditions. This method is applied to three line to line voltages of grid to derive three phase angle errors from three separated single-phase PLLs. They can substitute for abnormal phase to guarantee the synchronization in the various grid fault conditions. The performance of novel PLL with moving average method is verified through simulations.

  • PDF

Estimation of Head Loss Coefficient Empirical Formulas Using Model Experimental Results in a 90° Angle Dividing Channel Junction (90도 각도를 갖는 분기수로에서 모형실험결과를 이용한 손실계수 경험식 산정)

  • Park, Inhwan;Seong, Hoje;Kim, Hyung-Jun;Rhee, Dong Sop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.989-999
    • /
    • 2017
  • In this study, hydraulic experimental studies were conducted to estimate the empirical formulas of loss coefficient, which is necessary to calculate the energy loss occurred in the dividing channel junction of sewer system. The experimental apparatus was consisted of two outflow conduit with a $90^{\circ}$ angle to the inlet conduit, and the pressure and velocity heads are measured to analyze the energy losses in the branch. The measurements of the hydraulic grade line show that the hydraulic grade line was steeply descended at the dividing point due to the head loss, and the decreasing amount of velocity head increased with the increase of flowrate ratio. The head loss exponentially increased in the outlet with larger runoff as the increase of flowrate ratio and Froude number, and the head loss coefficient also increased. On the other hands, the head loss coefficients decreased in the outlet with smaller runoff as the increase of the flowrate ratio and Froude number. Using the experimental results, the empirical formulas of loss coefficient was suggested for each outlet, and the error of empirical formula was 3.91 and 5.19%, respectively. Furthermore, the total head loss coefficient calculated by the two empirical formulas was compared with the experimental results, and the error was 3.62%.

Continuous Viewing Angle Distribution Control of Liquid Crystal Displays Using Polarization-Dependent Prism Array Film Stacked on Directional Backlight Unit

  • Park, Min-Kyu;Park, Heewon;Joo, Kyung-Il;Jeong, Hee-Dong;Choi, Jun-Chan;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.799-806
    • /
    • 2016
  • We present a polarization-dependent prism array film for controlling the viewing angle distribution of liquid crystal (LC) display panels without loss of light efficiency. On a directional backlight unit, our polarization-dependent prism array film, made into a stacked bilayer with a well-aligned liquid crystalline reactive mesogen (RM) layer on the UV-imprinted prism structure, can continuously control the light refraction function of the prism array by electrically switching incident polarization states of a polarization-controlling layer prepared by a twisted nematic LC mode. The viewing angle control properties of the polarization-dependent prism array film are analyzed under different prism angle and refractive index conditions of the RM layer. A simple analytic model is also presented to describe the intermediate viewing angle distributions with continuously varying applied voltages and incident polarization states.

Evaluation of Flowfield and Flow Losses insied Axial Turbomachinery Using Numerical Calculation [Evaluation of Tip Leakage Loss and Reduction of Efficiency by Tip Clearance] (수치계산에 의한 축류터보기계의 유동장과 유동온실의 평가 III [회전차 익말단의 누설손실과 효율저하에 대한 평가])

  • Ro, Soo-Hyuk;Cho, Kang-Rae
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.240-247
    • /
    • 1998
  • Leakage vortices formed near blade tip causes an increase of total pressure loss near casing endwall region and as a result, the efficiency of rotor decreases. The reduction of rotor efficiency is related to the size of tip clearance. In this study, the three-dimensional flowfields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The effects of tip clearance and attack angle on the leakage vortex and overall performance, and the less distributions were investigated through numerical calculations. In this study, tip leakage flow rate and total pressure loss by tip clearance were evaluated using numerical results and aprroximate equations were presented to evaluate the reduction of rotor efficiency by tip leakage flow.

  • PDF

Magnetization Losses in YBCO Coated Conductors According to Angles of External Magnet Field (외부자장인가 방향에 따른 YBCO CC의 자화 손실 특성)

  • Lim, Hyoung-Woo;Lee, Sang-Su;Lee, Hee-Joon;Cha, Guee-Soo;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1222-1224
    • /
    • 2005
  • AC loss is an important factor in the development of superconducting tapes and superconducting power applications. In this paper, magnetization loss in YBCO coated conductor have been measured and compared with Brandt equation. Measurements of magnetization loss were performed under various angles of external magnetic field to consider the anisotropic characteristics of YBCO coated conductors. The results show that measured values of magnetization loss agreed well with the calculated value by using Brandt equation, especially at large degrees of incidence angle. The magnetization losses were strongly influenced by the direction of external magnet field as were expected.

  • PDF

A Second-Order Analysis of VM Heat Pumps (VM열펌프의 2차해석)

  • Choi, Y.S.;Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

Acoustic Performance Study of FRP Acoustic Window (FRP 음향창의 음향성능 설계기법 연구)

  • Seo, Young-Soo;Kang, Myeng-Whan;Shin, Ku-Kyun;Jeon, Jae-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.890-896
    • /
    • 2011
  • For developing acoustic window, transmission loss in accordance with incident angle was calculated and compared with measurement results. In design stage, the material choice of acoustic window is very important because the material is one of main parameters of transmission loss and structural strength. In order to analyze the effect of material properties on transmission loss, the parametric studies were carried out and the results were discussed in this paper. And, to verify the design specification of acoustic window, measurement was carried out and the results were compared and analyzed.

Acoustic performance study of FRP acoustic window (FRP 음향창의 음향성능 설계기법 연구)

  • Kang, Myeng-Whan;Seo, Young-Soo;Shin, Ku-Kyun;Jeon, Jae-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.285-290
    • /
    • 2011
  • For developing acoustic window, transmission loss in accordance with incident angle was calculated and compared with measurement results. In design stage, the material choice of acoustic window is very important because the material is parameter of transmission loss and structural strength. In order to analyze the effect of material properties on transmission loss, the parametric studies were carried out and the results were discussed in this paper.

  • PDF

Correlation of Cervical Disc Degeneration with Sagittal Alignments of Cervical Spine (두경부 시상면 정렬과 경추 추간판 퇴행성 변화와의 상관관계)

  • Jeon, Dae Geun;Park, Jinyoung;Park, Jung Hyun;Yun, Wang Hyeon
    • Clinical Pain
    • /
    • v.18 no.1
    • /
    • pp.8-15
    • /
    • 2019
  • Objective: To determine the relationship between cervical sagittal parameters and the degree of the cervical disc degeneration at each cervical level by using cervical plain radiographs and disc degeneration grading. Method: This study analyzed 110 patients with posterior neck pain. Cervical radiographic measurements included the occipito-cervical (O~C2) angle; sagittal Cobb angles of C1~C2, C2~C7; and sagittal vertical axis (SVA) of C1~C7 and C2~C7. The degenerations of cervical discs at each level were evaluated through Pfirrmann grading system by magnetic resonance images of the cervical spine. The correlations between the cervical sagittal measurements and the disc degeneration at each level were analyzed by Spearman's correlation. Results: A significant correlation was found for the C2~C7 angle with disc degenerations at C2~C6 levels. O~C2 angle was correlated significantly with disc degenerations at C2~C4 and C5~C7 levels. There was significant correlation between C1~C2 angle and disc degeneration at C6~C7 level. No significant relationship was found between the cervical SVA and the cervical disc degeneration at all cervical levels. Conclusion: Cervical sagittal parameters representing cervical angles (C2~C7, O~C2, and C1~C2 angles) were significantly correlated with the degree of the cervical disc degeneration. These findings suggest that the loss of the natural cervical lordosis rather than loss of natural SVA could be correlated with progression of the cervical disc degeneration.