• Title/Summary/Keyword: Lock-up

Search Result 167, Processing Time 0.024 seconds

Heat Transfer Analysis and Cooling Design for Crude Oil Pump System (원유펌프시스템의 열전달해석 및 냉각설계)

  • Kim, Wan-Gi;Lee, Joon-Yeob;Kwon, Jung-Lock;Kim, Hea-Choen
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2017-2022
    • /
    • 2008
  • The crude oil pump system is the equipment for transporting crude oil and it consists of 3 major components, a motor and an impeller which discharge underground crude oil, a pipestack that transmits the cooling oil and power, and a cooling oil unit & junction box that provides cooling oil and electric power. When considering the system characteristics that it has to be installed at a depth of deeper than 100 m, a design technology for the efficient control of the heat occurring at a conductor and motor is necessary and it is the essential factor for ensuring system durability. In this paper, therefore, cooling oil flow has been calculated to satisfy the limit value of the system temperature by analyzing heat flow considering the related losses such as loss of conductor, contact resistor loss at the conductor connection, and operation loss of motor. And the operation temperature has been set up based on the temperature of crude oil and the heat of motor and conductor. Also, a design for cooling of crude oil pump system has been proposed by calculating the operation pressure loss and selecting the capacity of a cooling oil pump and a heat exchanger.

  • PDF

Molecular Pharmacological Interaction of Phenylbutazone to Human Neutrophil Elastase

  • Kang, Koo-Il
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.3
    • /
    • pp.385-393
    • /
    • 1998
  • Human neutrophil elastase (HNElastase, EC 3.4.21.37), a causative factor of inflammatory diseases, was purified by Ultrogel AcA54 gel filtration and CM-Sephadex ion exchange chromatography. HNElastase was inhibited by phenylbutazone in a concentration dependent manner up to 0.4 mM, but as the concentration increased, the inhibitory effect gradually diminished. Binding of phenylbutazone to the human neutrophil elastase caused strong Raman shifts at 200, 440, and 1194 $cm^{-1}$. The peak at 1194 $cm^{-1}$ might be evidence of the presence $of\;-N=N-{\Phi}$ radical. The core area of the elastase, according to the visual molecular model of human neutrophil elastase, was structurally stable. A deeply situated active center was at the core area surrounded by hydrophobic amino acids. Directly neighboring the active site was one positively charged atom and two atoms carrying a negative charge, which enabled the enzyme and the drug to form a strong interaction. Phenylbutazone may form a binding, similar to a key & lock system to the atoms carrying opposite charges near the active site of the enzyme molecule. Furthermore, the hydrophobicity of the surrounding amino acid near the active site seemed to enhance the binding strength of phenylbutazone. Binding of phenylbutazone near the active site may cause masking of the active site, preventing the substrate from approaching the active site and inhibiting elastase activity.

  • PDF

Experimental Study on the Characteristics of Steel Hysteretic Dampers with E-Shape Elements (E-Shape 강재이력댐퍼의 거동 분석)

  • 김인배;강형택;이민구;서주원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.457-464
    • /
    • 2003
  • 최근 교량의 건설에 있어서 내진설계가 주요문제로 부각되면서, 구조물의 진동응답을 제어 하는 갖가지 형태의 진동제어 기법이 적용되고 있다. LRB(Lead Rebbe. Bearing), LUD(Lock Up Device)등 다양한 지진격리장치가 설계에 적용되고 있으며 특히, 설계변경 .내진보수보강과 같이 제약 조건이 있는 상황에서 유용한 면진방법으로 사용되고 있다. 이러한 지진격리장치는 기본적인 설계특성인 수평강성, 감쇠성능에 대한 검증을 필요로 한다. 특히, 지진과 같은 동적하중에 대하여 하중속도, 수직력, 변형률 등에 대한 의존성과 내구성의 검토가 필요하며 유사장치에 대하여 검증실험기준의 정립이 진행 중에 있다. 강재이력댐퍼인 E-Shape 댐퍼는 지진격리장치로서 교각의 고정단에 교좌장치로 설치되어 상시에는 탄성영역 내에서 거동하는 고정단의 역할을 하다가, 지진발생시에는 E-Shape형태의 강재댐퍼가 소성변형을 통한 이력거동으로 에너지 소산기능을 가진 교좌장치이다. 최근 LRB에 대하여는 다양한 특성실험이 수행되고 있으나 상대적으로 강재이력댐퍼에 대하여는 이러한 검증실험이 수반되지 않고 사용되고 있다. 본 실험연구에서는 E-Shape 강재이력댐퍼에 대하여 연직하중, 수평변형률, 수평속도에 패한 동적특성을 평가함으로서 강재이력댐퍼를 이용한 지진격리설계의 타당성과 면진성능을 평가해 보았다.

  • PDF

A Study on the Development of Safety_door System in Automation Facilities Workplaces (자동화 설비 사업장 안전 도어 시스템 개발에 대한 연구)

  • Gi-Cheol Lee;Man-Soo Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.25-30
    • /
    • 2024
  • Considering the difficulties of the manufacturing industry by improving production efficiency in the era of high wages and aging in domestic automation facilities, automation facilities are considered an irreversible trend, but many serious related disasters are occurring due to the problems of increasing automation facilities due to the enlargement of manufacturing processes, line-up, and automation. The purpose of this study is to review the usage conditions and safety measures for industrial robots that are experiencing serious industrial accidents and are expected to continue to increase in facilities among automation facilities at the automation industrial site and propose ways to ensure the fundamental safety of the facilities at all times The suggestions are as follows. The purpose is to prevent safety accidents in advance by applying safety door aids to industrial sites and installing additional safety devices in safety slide door lock systems applied to safety fence doors of new and already installed facilities to detach safety keys and ensure that workers carry them at all times.

A Study on Application Method of Brake System Modular Design for Medium and Large EV Architecture (중형 및 대형 EV 아키텍처를 위한 제동시스템 모듈러 설계 적용 방안에 관한 연구)

  • J. H. Shim;S. R. Hwang
    • Journal of Auto-vehicle Safety Association
    • /
    • v.16 no.1
    • /
    • pp.21-28
    • /
    • 2024
  • Many global car manufacturers in the world are recently developing a variety of electric vehicles in response to demanding market needs. Also, they have adapted the architecture method in order to develop electric vehicles effectively. It is because architecture method can produce various electric vehicles with high profitability. However, when electric vehicles are being developed, brake system has a lot of demanding tasks in relation to deciding specification of brake system because of heavy vehicle weight, narrow power electric room space and large volume of electric hydraulic booster. In this paper, a new approach is proposed for deciding the front and rear brake systems in order to design the brake system of electric vehicles effectively. To do this, we study correlations among vehicle weight, layout of power electric room and volume of electric hydraulic booster. And then, we also study combination of hydraulic braking and regenerative braking which is widely applied to electric vehicles. Finally, we want to contribute to build up modular design of brake system for architecture of electric vehicles through these studies.

Template therapy for mouth opening limitation by temporomandibular joint disorders (턱관절원판 전방 변위로 인한 개구 장애의 템플레이트 치료)

  • Lee, Gi-Cheol;Shin, Seung-Woo;Pyo, Sung-Woon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.270-274
    • /
    • 2010
  • Introduction: Limited mouth opening is a representative clinical symptom of temporomandibular disorders (TMD) with anterior disc displacement without reduction (ADDWOR). Various treatment methods have been proposed for patients with ADDWOR. This study examined the clinical effectiveness of template therapy for patients with mouth opening difficulty due to the ADDWOR. Material and Methods: A total of 14 patients (female 12, male 2, average age: $29.1{\pm}14.4$), who had been treated in the template clinic, Sooncheonhyang University Bucheon Hospital, from January of 2006 to December of 2008, were enrolled in this study. The subjects were selected according to the following criteria: more than 2 weeks after the onset of locking, mouth opening range <35 mm, and confirmed ADDWOR without a synovial pathology by magnetic resonance imaging (MRI). All patients were treated with the template appliance, instructed to wear it while sleeping and exercise for at least 10 hours per day. The maximum mouth opening (MMO) range and pain recognition scores before and after template therapy were recorded and compared. A paired t-test and Wilcoxon's signed rank test were used for statistical analysis. Results: After the periodical follow up, significant improvement in the opening range was observed in the template treatment group. The average MMO range before treatment was $30.2{\pm}3.5mm$ and the average MMO after treatment and follow up was $47.1{\pm}4.7mm$. The mean amount of mouth opening increment was $16.9{\pm}5.4mm$ (P<0.01) and the pain recognition scores before and after treatment was also improved.(P=0.001) Conclusion: The template appliance proved to be efficient for the treatment of TMD with a closed lock and painful joint due to ADDWOR.

Population Stereotypes as a Perceiver's Cognitive Structure on Manipulating Devices for Daily Use (일상생활용 장치 작동에 따른 지각자의 인지구조에 대한 집단고정관념)

  • Jung, Hwa-Shik;Kang, Jeong-Il;Jung, In-Ju;Shin, Hong-Cheul;Jeong, Dong-Hyuk;Jung, Yu-Jin
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.4
    • /
    • pp.71-78
    • /
    • 2008
  • Purpose: This study standardizes the position and direction of devices based on general user expectations and stereotypes. Population stereotypes are cognitive structures that contain the perceiver's knowledge, beliefs, and expectations about human groups. In this paper, the stereotypes that people typically expect when manipulating 'cylindrical key-in-knob locks' and 'lever-type water faucet handles' were investigated and data regarding their expectations were collected. Methods: Two sets of 600 participants, between 13 and over 60 years old, were recruited for the experiment. Each group was evenly subdivided into six age groups. Each participant was presented with cylindrical door locks mounted on a miniature door and actual lever-type water faucet handles mounted on a mockup sink. Results: If the cylindrical lock was positioned 'vertically,' 59.2% of the participants expected the device to be locked, and if the lever type faucet handle was positioned 'up,' 63.0% of the participants expected the device to be turned on. Thus, daily-use devices should be designed consistent with user expectations of operation. There was a significant difference between genders for manipulating the faucet handle between up and down. Conclusion: A more general stereotype may be defined by repetitive measurements under the same test conditions with fixed time intervals, as well as accounting for people with cognitive problems.

  • PDF

Development and feasibility test of sit-to-stand transfer assistive device

  • Ha, SinHo;Jeong, SeYeon;Hong, SoungKyun;Choi, Wonjae;Lee, Kwangkook;Park, Donghwan;Son, SangJun;Shin, HyeonHui;Lee, GyuChang
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.41-46
    • /
    • 2022
  • Background: The purpose of this study was to develop a sit-to-stand transfer assistive device, and to conduct a feasibility test. Design: A technical note. Methods and results: In this study, we developed a sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. The sit-to-stand transfer assistive device allows the user to transfer the weight from a sitting position to a standing position while shifting the weight forward by grabbing and pulling a support stand. Ten healthy adults participated in the feasibility test of the device. Each participant used the developed sit-to-stand transfer assistive device and investigated supplementation through a brief interview. As a result of the feasibility test, the opinion was that the device could assist the sit-to-stand transfer to some extent. There were opinions that it needed a function to adjust the height of the knee protective plate in the sitting position according to the user's physical characteristics. Because of the inconvenience of operating the lock device for fixing the position and adjusting inclination, there was an opinion that the improvement for a locking device is needed. There were opinions that it would be better to reduce the size of the device due to its inconvenience of portability. Conclusion: In this study, we developed the sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. In addition, it is considered that the upgrade of the device is necessary for the future since there are supplementary opinions on some points.

Fractional-N PLL Frequency Synthesizer Design (Fractional-N PLL (Phase-Locked Loop) 주파수 합성기 설계)

  • Kim Sun-Cheo;Won Hee-Seok;Kim Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.7 s.337
    • /
    • pp.35-40
    • /
    • 2005
  • This paper proposes a fractional-N phase-locked loop (PLL) frequency synthesizer using the 3rd order ${\Delta}{\sum}$ modulator for 900MHz medium speed wireless link. The LC voltage-controlled oscillator (VCO) is used for the good phase noise property. To reduce the lock-in time, a charge pump has been developed to control the pumping current according to the frequency steps and the reference frequency is increased up to 3MHz. A 36/37 fractional-N divider is used to increase the reference frequency of the phase frequency detector (PFD) and to reduce the minimum frequency step simultaneously. A 3rd order ${\Delta}{\sum}$ modulator has been developed to reduce the fractional spur VCO, Divider by 8 Prescaler, PFD and Charge pump have been developed with 0.25um CMOS, and the fractional-N divider and the third order ${\Delta}{\sum}$ modulator have been designed with the VHDL code, and they are implemented through the FPGA board of the Xilinx Spartan2E. The measured results show that the output power of the PLL is about -lldBm and the phase noise is -77.75dBc/Hz at 100kHz offset frequency. The minimum frequency step and the maximum lock-in time are 10kHz and around 800us for the maximum frequency change of 10MHz, respectively.

An alternative way of Animation Industry : Focusing on Avatar sevice's Lock-in Effect (애니메이션 산업의 대안적 연구 - 아바타 서비스의 소비자 고착화(lock-in) 전략을 중심으로)

  • Han, Chang-Wan
    • Cartoon and Animation Studies
    • /
    • s.6
    • /
    • pp.152-171
    • /
    • 2002
  • This study analyses the avatar service, which is recognized as an alternative strategy of animation industry. The research questions of this study are following: (1) How have the avatar services been developed and what are the present dominant types? (2) Which structural characteristics of e-business environment are needed for the success of avatar services? (3) What is the economic characteristics of avatar business model? To solve these research questions, the basic conditions and the structural characteristics of avatar services have been investigated. In the first place, two forms of avatar service are classified. One is the internet service site whole primary service is to provide chatting service based on avatar service. The other is the portal site in which many kinds of products and services are presented as bundles to meet the needs of internet users. So avatar service is one of bundles which those portal sites are providing with. In this study, the big five internet service sites are selected based on the profits they earned through the sales of avatar service. The result of analysis is that the pricing strategy of those big five sites is very different from those of traditional off-line markets. The pricing mechanism are based on the value which internet users endow with the avatar items, not based on the costs of making the products. Avatar is the representative informative goods. The informative goods have the original cost structures, constant fixed costs and zero marginal costs, so the providers of avatar services make much of the subjective values of consumers. The sayclub, which is the most successful avatar service site and earn the average sales of 3 billing won a month, takes the aggressive strategy of pricing avatar items at highest price in the industry. The avatar service providers which make lots of profits are planning of making differentiate the services, introducing well-known brand items and star-named items. Nevertheless, the fact that the members of the sayclub are not decreasing means that the network effect of the site is so strongly manifest. Moreover, the costs the members have paid for the avatar items are so big not as to switch from one site to the other site, it can be very costly. These switching costs are endemic in high-technology industries and digital contents industries. It can be so large that switching suppliers is virtually unthinkable, a situation known as 'lock-in'. When switching costs are substantial, competition can be intense to attract new customers, since, one they are locked in, they can be a substantial source of profit. The consumers of avatar items have switching costs if they subscribe for the new avatar service site. The switching costs can be subscription costs as well as the costs of giving up the items they already paid for. One common example of switching costs involves specialized supplies, as with inkjet printer cartridges. In this example, the switching cost is the purchase of a new printer. The market is competitive ex ante, but since cartridges are incompatible, it is monopolized dx post. So the providers of printer/cartridges set pricing printer so cheap and cartridges expensive. On the contrary, since the avatar service can be successful with the strong network effect, the providers of avatar services have to compete aggressively for new customers. So they allow the subscription at a low price(almost marginal cost) in the early market. The network effect can be maximized when the members are sufficiently growing. The providers which have the monopoly power with sufficient subscribers. begin to raise the prices over the lifetime of the product and make profits.

  • PDF