• Title/Summary/Keyword: Lock-in Effect

Search Result 152, Processing Time 0.024 seconds

Analysis of Magnetic Field Application Effect on Fault Current Limiting Characteristics of a Flux-lock Type SFCL

  • Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.255-259
    • /
    • 2008
  • The magnetic field application effect on resistance of a high-$T_c$ superconducting (HTSC) element comprising a flux-lock type superconducting fault current limiter (SFCL) was investigated. The YBCO thin film, which was etched into a meander line using a lithography, was used as a current limiting element of the flux-lock type SFCL. To increase the magnetic field applied into HTSC element, the capacitor was connected in series with a solenoid-type magnetic field coil installed in the third winding of the flux-lock type SFCL. There was no magnetic field application effect on the resistance of HTSC element despite the application of larger magnetic field into the HTSC element when a fault happened. The resistance of HTSC element, on the contrary, started to decrease at the point of four periods from a fault instant although the amplitude of the applied magnetic field increased.

Analysis of Frequency Lock-in Breakings with Random Dithering in a Ring Laser Gyroscope (랜덤 디더링을 이용한 링레이저 자이로 주파수 잠김 깨짐 특성 분석)

  • Woo-Seok Choi;Byung-Yoon Park
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.2
    • /
    • pp.76-83
    • /
    • 2023
  • In this paper, the results of analyzing the frequency lock-in breaking characteristics of a ring laser gyroscope with random dithering through numerical experiments are presented. By observing the variant features in the frequency lock-in characteristics according to the dithering amplitude noise, it was possible to analyze the minimum noise condition that causes the frequency lock-in to be broken. It was confirmed that the result is closely related to the relative difference between the dynamic frequency lock-in corresponding to the average dithering amplitude and the frequency determined by the Sagnac effect corresponding to an input rotational angular velocity.

Comparison of Fault Current Limiting Characteristics between the separated Three-phase Flux-lock Type SFCL and the Integrated Three-phase Flux-lock Type SFCL (분리된 삼상 자속구속형 전류제한기와 일체화된 삼상 자속구속형 전류제한기의 전류제한 특성 비교)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.689-693
    • /
    • 2009
  • We investigate the comparison of fault current characteristics between the separates three-phase flux-lock type superconducting fault current limiter(SFCL) and integrated three-phase flux-lock type superconducting fault current limiter(SFCL). The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core and superconducting elements are connected to secondary coil in series. Superconducting elements are used by the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. But the integrated three-phase flux-lock type SFCL consists of three-phase flux-reactors wound on an iron core. Flux-reactor consists of the same turn's ratio between coil 1 and coil 2 for each single phase. To compare the current limiting characteristics of the separated three-phase flux-lock type SFCL and integrated three-phase flux-lock type SFCL, the short circuit experiments are carried out fault condition such as the single line-to-ground fault. The experimental result shows that fault current limiting characteristic of the separated three-phase flux-lock type SFCL was better than integrated three-phase flux-lock type SFCL. And the integrated three-phase flux-lock type SFCL has an effect on sound phase.

THE EFFECT OF MASKED SIGNAL ON THE PERFORMANCE OF GNSS CODE TRACKING SYSTEM

  • Chang, Chung-Liang;Juang, Jyh-Ching
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.223-228
    • /
    • 2006
  • The main purpose of this paper is to describe the code tracking performance of a non-coherent digital delay lock loop (DLL) or coherent DLL while tracking GNSS signal in the presence of signal masking. The masking effect is usually caused by buildings that obscure the signal in either a periodic or random manner. In some cases, ideal masking is used to remove random or periodic interference. Three types of the masked signal are considered - no masking, periodic masking, and random masking of the signal input to the receiver. The mean time to lose lock (MTLL) of the code tracking loop are evaluated, and some numerical result and simulation results are reported. Finally, the steadystate tracking errors on the performance of the tracking loop in interference environment are also presented.

  • PDF

Cases Report on Conservative Treatment for the Chronic Closed Lock of Temporomandibular Joint

  • Lee, Gi-Cheol;Park, Su-Hyun
    • Journal of Korean Dental Science
    • /
    • v.4 no.2
    • /
    • pp.85-91
    • /
    • 2011
  • Some treatment methods have been proposed for patients with chronic closed lock of temporomandibular joint. We report a conservative treatment for patients who had chronic closed lock of temporomandibular joint and who did not want surgical treatment. Two patients who had been treated in the Template clinic, Soonchunhyang University Bucheon Hospital, are the subjects of this report. The subjects had chronic closed lock symptom for over 3 months after an onset of locking; conventional therapies had no effect. The subjects were treated by making them wear a Template appliance while sleeping and exercise for 10 hours a day. After periodic follow-up, significant improvement was observed for Template treatment in terms of the maximal mouth opening range. When conventional therapy is expected to be ineffective, The Template appliance can be used as conservative treatment for temporomandibular disorders patients with chronic closed lock of temporomandibular joint.

Effect of Lock-up Control Strategy on Vehicle Fuel Economy (자동변속기 차량의 직결영역 변화에 따른 연비 특성에 관한 연구)

  • Kim, Woo-Seok;Han, Chang-Ho;Kim, Nam-Kyun;Park, Kyung-Seok;Park, Jin-Il;Lee, Jong-Hwa
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.9-15
    • /
    • 2006
  • Experiments are conducted to compare fuel economy of FTP-75 mode on two different lock-up conditions; (A) Lock-up on at engine speed of 1,200(rpm) and above for 3rd & 4th gear, (B) Lock-up on at engine speed of 1400rpm and above for 4th gear only. As a result, case A had better fuel economy about 2.75(%) than case B for FTP-75 mode. Simulation(CRUISE, AVL) study is also carried out in order to estimate the effect of Lock-up control strategy for vehicle fuel economy. The fuel economy simulation result agrees with the measured fuel economy within error of 2(%). The improved Lock-up control strategy is proposed by simulation.

Effect of lock-on frequency on vortex shedding in the cylinder wake

  • Yoo Jung Yul;Sung Jaeyong;Kim Wontae
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.86-99
    • /
    • 2001
  • Vortex lock-on or resonance in the flow behind a circular cylinder is investigated from a time-resolved PIV when a single frequency oscillation is superimposed on the mean incident velocity. Measurements are made of the $K\acute{a}rm\acute{a}n$ and streamwise vortices in the wake-transition regime at the Reynolds number 360. Streamwise vortices at the lock-on and natural shedding states are observed, as well as the changes in the wake region with the change of the shedding frequency of lock-on state. When lock-on occurs, the vortex shedding frequency is found to be half the oscillation frequency as expected from previous experiments. At the lock-on state, the $K\acute{a}rm\acute{a}n$ vortices are observed to be more disordered by the increased strength and spanwise wavelength of the streamwise vortices, which leads to a strong three-dimensional motion. Recirculation and vortex formation region at the lock-on state is reduced as the oscillating frequency is increased. By comparing the Reynolds stresses at the lock-on and natural shedding states, $\bar{u'u'}\;and \;\bar{u'u'}$ at the lock-on state are concentrated on the shear layer around the cylinder. The $\bar{u'u'}\;at\;f_o/f_n=2.0$ has a large value near the centerline, compared with that of other cases. Considering the traces of maximum of u', in the wake region near the cylinder, wake width at the lock-on state is wider than that at the natural shedding state.

  • PDF

Analysis on Fault Current Limiting Characteristics of Flux-Lock Type SFCL Using Magnetic Flux Application Circuit (자기인가회로를 이용한 자속구속형 초전도한류기의 고장전류제한 특성 분석)

  • Go, Ju-Chan;Lim, Seung-Taek;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.1
    • /
    • pp.37-41
    • /
    • 2017
  • In this paper, the fault current limiting characteristics of the flux-lock type SFCL (superconducting fault current limiter) using magnetic application circuit were analyzed. The flux-lock type SFCL has the structure to install the magnetic application circuit, which can increase the resistance of HTSC ($high-T_C$ superconducting element comprising) the SFCL. To analyze the fault current limiting effect of the flux-lock type SFCL through the magnetic flux application circuit, the flux-lock type SFCL either with the magnetic flux circuit or without the magnetic flux circuit was constructed and the fault current limiting characteristics of the SFCL were compared each other through the short-circuit tests.

Characteristics of a Flux-Lock Type Superconducting Fault Current Limiter According to the Parallel Connection of the Superconducting Elements. (초전도 한류소자의 병렬연결에 따른 자속구속형 초전도 한류기의 특성 분석)

  • Oh, Kum-Gom;Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.198-201
    • /
    • 2008
  • We investigated the operating characteristics of the flux-lock type superconducting fault current limiter(SFCL) with the parallel connection between the primary and secondary windings which are connected with two superconducting units in series. The parallel connection for current level increase of the flux-lock type SFCL is necessary to apply the SFCL into the power system. The resistance generated in superconducting units was dependent upon the winding direction of the primary and the secondary coils, which can reduce the power burden. The resistance of the superconducting elements in the subtractive polarity winding is higher than that of the additive polarity winding. The fault current limiting effect of the subtractive polarity winding is better than that of the additive polarity winding. From this results, we confirmed that the power capacity of the flux-lock type SFCL could be increased by the parallel connection of the superconducting units.

Finite element analysis of the effect of novel Lock Screw system preventing abutment screw loosening (지대주 나사 풀림 방지를 위한 새로운 Lock Screw 시스템의 효과에 대한 유한요소해석적 연구)

  • Im, Eun Sub;Kim, Jong Eun;Kim, Jee Hwan;Park, Young Bum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.132-142
    • /
    • 2019
  • Purpose: The purpose of this finite element analysis study is to introduce the novel Lock screw system and analyze its mechanical property to see if it can prevent abutment screw loosening. Materials and Methods: The Lock screw is a component tightened on the inside of the implant abutment which applies compressive force to the abutment screw head. To investigate the effect, modeling was done using CAD program and it was analyzed by finite element analysis under various load conditions. First, the preload was measured according to the tightening torque of the abutment screw then it was compared with the theoretical value to verify the analytical model. The validated analytical model was then divided into those with no external load and those with 178 N, and the tightening torque of the lock screw was changed to 10, 20, 30 Ncm respectively to examine the property of stress distribution on the implant components. Results: Using Lock screw under various loading conditions did not produce equivalent stresses beyond the yield strength of the implant components. In addition, the axial load was increased at the abutment-abutment screw interface. Conclusion: The use of Lock screw does not exert excessive stress on the implant components and may increase the frictional force between the abutment-abutment screw interface, thus it is considered to prevent loosening of the abutment screw.