• Title/Summary/Keyword: Location measurement

Search Result 1,284, Processing Time 0.028 seconds

Development of Relative Position Measuring Device for Moving Target in Local Area (국소영역에서 이동표적의 상대위치 측정 장치 개발)

  • Seo, Myoung Kook
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.8-14
    • /
    • 2020
  • Intelligent devices using ICT technology have been introduced in the field of construction machinery to improve productivity and stability. Among the intelligent devices, Machine Guidance is a device that provides real-time posture, location, and work range to drivers by installing various sensors, controllers, and satellite navigation systems on construction machines. Conversely, the efficiency of equipment that requires location information, such as machine guidance, will be greatly reduced in buildings, and tunnels in the GPS blind spots. Thus, the other high-precision positioning technologies are required in the GPS blind spot zone. In this study, we will develop a relative position measurement system that provides precise location information such as construction machinery and robots in a local area where the GPS reception is difficult. A relative position measurement system tracks a marker in the form of a sphere installed on a vehicle by using the image base tracking technology, and measures the distance and direction information to the marker to calculate a position.

Measurement-based AP Deployment Mechanism for Fingerprint-based Indoor Location Systems

  • Li, Dong;Yan, Yan;Zhang, Baoxian;Li, Cheng;Xu, Peng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1611-1629
    • /
    • 2016
  • Recently, deploying WiFi access points (APs) for facilitating indoor localization has attracted increasing attention. However, most existing mechanisms in this aspect are typically simulation based and further they did not consider how to jointly utilize pre-existing APs in target environment and newly deployed APs for achieving high localization performance. In this paper, we propose a measurement-based AP deployment mechanism (MAPD) for placing APs in target indoor environment for assisting fingerprint based indoor localization. In the mechanism design, MAPD takes full consideration of pre-existing APs to assist the selection of good candidate positions for deploying new APs. For this purpose, we first choose a number of candidate positions with low location accuracy on a radio map calibrated using the pre-existing APs and then use over-deployment and on-site measurement to determine the actual positions for AP deployment. MAPD uses minimal mean location error and progressive greedy search for actual AP position selection. Experimental results demonstrate that MAPD can largely reduce the localization error as compared with existing work.

A Location Technique Based On Calibrated Radio Frequency Propagation Model For Wireless Local Area Networks (교정된 전파전파 모델에 기반한 WLAN 측위 기법)

  • Kim, Hee-Sung;Shim, Ju-Young;Choi, Wan-Sik;Lee, Hyung-Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.8
    • /
    • pp.760-766
    • /
    • 2008
  • This paper proposes an efficient location technique to find an indoor location under the IEEE 802.11 wireless local area networks. The proposed method is based on the range measurements obtained from a simple radio frequency propagation model. Thus, unlike the radio frequency fingerprint correlation method, it does not suffer from the computational burden during the real-time location service period and can quickly reply the location requests of many users at the same time. To increase the location accuracy in spite of the frequent non-line-of-sight error occurrences, the proposed method calibrates the distortion of the non-line-of-sight error by a simple measurement surveying procedure that does not require the surveyor's manual interaction. Experimental results show the capability of the proposed method.

NLOS Mitigation for TOA Location Based on Pattern Matching Algorithm

  • Hur, Soojung;Akbarov, Dilshod;Park, Yongwan
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.4 no.2
    • /
    • pp.63-68
    • /
    • 2009
  • The location of mobile terminals in cellular networks is an important problem in the field of information technology with applications in resource allocation, location sensitive browsing, and emergency communications. Finding location estimation techniques that are robust to non-line of light (NLOS) propagation is a key problem in this area. Time of arrival (TOA) and pattern matching (PM) measurements can be made simultaneously by CDMA cellular networks at low cost. The different sources of errors for each measurement type cause TOA and PM measurements to contain independent information about mobile station (MS) locations. This paper combines the information of PM and TOA measurements to calculate a superior location estimate. The proposed location estimator is robust, provides lower error than the estimators based on the individual measurements, and has low implementation costs.

  • PDF

The study on the LBS for WiBro repeater (휴대인터넷 중계기를 위한 LBS 적용 방안에 관한 연구)

  • Ahn Jun-Bae;Ryoo Kyoo-Tae
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.53-56
    • /
    • 2006
  • WiBro service provider have made an effort to provide the subscriber's location and have deployed LBS system using cell-ID method. Cell-ID method has a location error problem if repeater is used on the other cell places at the same time. We introduce and analysis LMU(Location Measurement Unit) on the repeater fer location detection of subscriber which is serviced via the repeater. In this paper we propose the method using LMU on the repeater to avoid these location errors and to provide more exact location to the subscriber. we can conclude that the location error can be more exact at the building which uses repeater. It represents in which level the subscriber is serviced at the building.

  • PDF

Measurement and Analysis of Insulation Detects of Cast-resin Transformers using Antenna (안테나를 이용한 몰드변압기 절연결함 측정기법 연구)

  • Choi, Myeong-Il;Kim, Jae-Jin;Han, Ga-Ram;Jeon, Jeong-Chay;Lee, Hyun-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1937-1942
    • /
    • 2016
  • Unlike oil immersed transformers, cast-resin transformers have the solid insulator 'epoxy resin' in sealed structure. Therefore, they reveal a lot of limitations in checking aging conditions and predicting an accident. This study analyzed the characteristics of Cast-resin transformers by the measurement distance and measurement sensitivity with a corona defect sample, using antenna sensor. Therefore, the experiment has proven that the antenna sensor-based measurement method proposed in this study is able to detect the insulation defect location of the cast-resin transformer, unlike conventional measurement methods. It is expected that the result of this study will be used to develop a new type of measuring method in order to measure insulation defects and to use in safety inspection of domestic cast-resin transformers.

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

A Implementation of Electronic Measurement Datum Point Monitoring S/W based on Object-Oriented Modeling for Multi Purpose and High Availability (다목적 및 고활용성을 위한 객체지향 모델링 기반의 전자 측량기준점 모니터링 S/W 구현)

  • Jung, Se-Hoon;Sim, Chun-Bo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.2
    • /
    • pp.99-112
    • /
    • 2015
  • Datum point for displaying location and altitude of point has being advantage usefully in various measurement parts. However, datum point has been increasing loss cases owing to weather changes and stratum changes and neglecting meaninglessly. In this paper, we design and implement a multi electronic measurement system monitoring software with functions such as include maximize utilization of existing measurement datum system as well as collected various environment data and detection stratum changes of surround area. Proposed software is implemented to support that reusability and extensibility of software using object oriented modeling method. Our software supports a GUI for electronic measurement datum point administrator as well as for web user and mobile user. Our system can support a graph GUI for various data analysis and reposition in realtime to database that measured location information and various sensing information to prevent loss of electronic measurement datum point and to detected stratum changes. In addition, we include a QR code and RFID recognition function. Finally, we suggest performance evaluation result to confirm stratum changes detection and GPS location error rate.

The Study to standardize the ST36 Acupoint Location on Rats (흰쥐에서 족삼리 취혈 위치 표준화를 위한 연구)

  • Kim, Jong-Yeop;Choi, Il-Hwan;Hong, Yo-Han;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.27 no.3
    • /
    • pp.97-108
    • /
    • 2010
  • Background : The location of acupoints on rat, which may differ from that of human body due to anatomical structure, is defined variously among researchers, which may cause the problem of low repeatability and objectivity. Design : The measurement of hind limb consist of measuring the distance between knee joint and tibia tubercle in order to set the knee joint as common criteria. Based on it, the three mostly referred location of ST36 were represented with the knee joint as a datum point and compared. The electroacupuncture stimulation was administrated after the abdominal pain was induced by acetic acid. And the analgesic activity of each ST36 acupoint was evaluated by measuring the number of writhing reflex, in order to observe the differences of treatment effect in accordance with the location of ST36 acupoints. Results : The result of measurement confirmed the differences in the acupoint location of ST36 among researchers. The writhing reflex test using the acetic acid-induced abdominal pain stimulated with electroacupuncture of 100Hz showed that there were statistically significant differences in the analgesic effect between control group and three ST36 groups (P<0.05). However there were no differences observed among three mostly referred location of ST36 acupoints (P>0.05). Conclusions : We recommend "the point located 6.5 mm below the knee joint at the anterior tibial muscle" as a standard ST36 acupoint location qualified by the WHO Standard Acupuncture Point Locations in 2008.

Probing of Steel Bar Location inside Concrete using Multi-electrode Array (다전극 배열을 이용한 콘크리트 매립 철근의 위치탐사)

  • 이형우;임홍철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.663-666
    • /
    • 2003
  • Using numerical analysis modeling of Multi-electrode Array that could be applied to the corrosion state measurement of a reinforcing steel bar in concrete, the steel bar location inside concrete can be probed by the investigation of the change of the measured impedance from concrete surface determined by the electrical impedance of interface between the steel bar and concrete, the electrical resistivity of concrete, the array of electrodes and the relative location and diameter of the steel bar.

  • PDF