• 제목/요약/키워드: Load-Cell

검색결과 1,187건 처리시간 0.031초

Effect of Load Modeling on Low Frequency Current Ripple in Fuel Cell Generation Systems

  • Kim, Jong-Soo;Choe, Gyu-Yeong;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.307-318
    • /
    • 2010
  • In this work, an accurate analysis of low frequency current ripple in residential fuel cell power generation systems is performed based on the proposed residential load model and its unique operation algorithm. Rather than using a constant dc voltage source, a proton exchange membrane fuel cell (PEMFC) model is implemented in this research so that a system-level analysis considering the fuel cell stack, power conditioning system (PCS), and the actual load is possible. Using the attained results, a comparative study regarding the discrepancies of low frequency current ripple between a simple resistor load and a realistic residential load is performed. The data indicate that the low frequency current ripple of the proposed residential load model is increased by more than a factor of two when compared to the low frequency current ripple of a simple resistor load under identical conditions. Theoretical analysis, simulation data, and experimental results are provided, along with a model of the load usage pattern of low frequency current ripples.

Case Study of Shape Design of Load Cell Using Finite Element Method

  • Reaugkittakarn, Saravut;Sripituk, Jettiya;Pongswatd, Sawai;Pannil, Pittaya;Ukakimapurn, Prapart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2054-2057
    • /
    • 2005
  • In this paper, the application of finite element method to design the shape of load cell as an illustrative case study is described. The relationship between the various shapes of load cell and their stress characteristic were analyzed by COSMOS simulation program. The results obtained from the proposed analysis can be applied to determine the appropriate position of strain gauges for good quality load cell. The experimental results show the good efficiency of the proposed technique.

  • PDF

슬리브관을 갖는 로드셀을 이용한 주퇴봉 당김력 계측시스템 개발 (A Development of the Recoil Rod Pull Force Measurement System Using the Load Cell with Sleeve)

  • 최주호;홍성수;유준
    • 제어로봇시스템학회논문지
    • /
    • 제7권2호
    • /
    • pp.152-159
    • /
    • 2001
  • This paper presents a development of the recoil rod pull force measurement system suing the load cell with a sleeve normally available in the recoil system test. The commercial load cell cannot be used in the test of recoil system floating the breach contact point freely in the air. The load cell is designed and manufactured to meet the recoil system test condition. Theoretical analysis and experimental results show that the accuracy of the developed measurement system is within $\pm$0.5%. We notice that the measurement technique proposed in this paper is accurate and useful in the recoil rod pull force measurement of the recoil system.

  • PDF

정밀 3분력(Fz, Fy, Mz) 로드셀의 설계 및 변형률해석 (Design and Strain Analysis of Precision 3-component Load Cell)

  • 김갑순;이세헌;엄기원
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.222-232
    • /
    • 1999
  • This paper describes the development of a precision 3-component load cell with plate beams which may be used for measuring forces Fx, Fy and moment Mz simultaneously in industry. We have derived equations to predict the bending strains on the surface of the beams under forces or moment. We have also determined the attachment location of strain gages of each sensor and fabricated 3-component load cell. To evaluate the rated strain and interference error of each sensor, we have carried out characteristic test of precision 3-component load cell. It reveals that the rated strain calculated from the derived equations are good agreement with the results from Finite Element Method analysis.

  • PDF

가변선단재하판을 이용한 양방향말뚝재하시험의 모형실험 (Model Test of O-Cell Pile Load Test with Variable End Plate)

  • 주용선;김낙경;김성규;김웅진;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.476-481
    • /
    • 2009
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurization causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. The O-cell pile load test with variable end plate is operated on second steps - the first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell.

  • PDF

편심하중이 작용하는 제형 다실박스거더에서의 거동분리연구 (A study of decomposition of applied eccentric load for multi-cell trapezoidal box girders)

  • 김승준;한금호;박남회;강영종
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.229-234
    • /
    • 2005
  • Thin-walled multicell box girders subjected to an eccentric load can he produced the three global behaviors of flexure, torsion, and distortion. Specially in railway bridges subjected to much eccentric load, it is quite important to evaluate influences of torsion and distortion. But it is very difficult to evaluate each influences of major behaviors numerically. If we can decompose an eccentric load P into flexural, torsional, and distortional forces. we can execute quantitative analysis each influences of major behaviors. Decomposition of Applied Load for Thin-walled Rectangular multi-cell box girders is reserched by Park, Nam- Hoi(Development of a multicell Box Beam Element Including Distortional Degrees of Freedom, 2003). But researches about trapezoidal multi-cell section is insufficient. So, this paper deals with multi-cell trapezoidal box girders. An expanded method, which is based on the force decomposition method for a single cell box girder given by Nakai and Yoo, is developed herein to decompose eccentric load Pinto flexural, torsional, and distortional forces. Derive formulas by decomposition of eccentric load is verified by 3D shell-modelling numerical analysis.

  • PDF

농업용 이동편의장치를 위한 발로 미는 힘을 감지하는 센서 구현 (Implementation of a Sensor to Detect the Foot-pushing Force for an Agricultural Transport-convenience Vehicle)

  • 백승희;권익현;김청월
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.411-417
    • /
    • 2022
  • In this paper, we propose a sensor with a C-shaped load cell to detect force change when a person sitting on the chair in an electrical transport-convenience vehicle is pushing ground by both heels. The load cell built in the vehicle is mechanically deformed by the vertical force owing to the human weight and the horizontal force by ground-pushing feet. The deformation rate of the load cell and its distribution are simulated using finite element analysis. In the simulation, the applied loads are preset in the range of 10 kg - 100 kg with a step size of 10 kg, and the ground-pushing force by feet is increased to 40 N with a step size of 5 N with respect to each applied load level. The resistance change of the load cell was observed to be linear in simulation as well as in measurement. the maximum difference between simulation and measurement was 0.89 % when the strain gauge constant was 2.243. The constant has a large influence on the difference. The proposed sensor was fabricated by connecting an instrument amplifier and a microcontroller to a load cell and used to detect the force by ground-pushing feet. To detect foot driving, the reference signal was set to 130% of the load, and the duration of the sensor output signal exceeding the reference signal was set to 0.6 s. In a test of a vehicle built with the proposed sensor, the footpushing force by the worker could be successfully detected even when the worker was working.

연료전지 트럭의 운전 부하 패턴에 따른 고분자 연료전지 스택의 동특성 시뮬레이션 (Dynamic Simulation of Proton Exchange Membrane Fuel Cell Stack under Various Operating Pattern of Fuel Cell Powered Heavy Duty Truck)

  • 손나민;무자히드 나심;김의연;이영덕
    • 한국수소및신에너지학회논문집
    • /
    • 제35권2호
    • /
    • pp.121-128
    • /
    • 2024
  • In this study, a dynamic simulation model of a heavy-duty truck, equipped with a fuel cell power-train, has been developed and the dynamic behavior of the fuel cell stack has bee investigated using. Output change simulations were performed according to several drive cycle load change of a fuel cell truck. Mathworks' Simulink and Simscape program were used to develop the model. The model is comprised of fuel cell power train, power converter system and truck vehicle part. The vehicle runs at targeted speed of the truck, which is set as the load of the system. The dynamic behavior of the fuel cell stack according to the weight difference were analyzed, and based on this, the dynamic characteristics of the fuel cell output power and battery state with simple load was analyzed.

계량설비용 디지탈 출력 로드셀의 개발에 관한 연구 (A Study on the Development of Digital Output Load Cell)

  • 박찬원;안광희
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권1호
    • /
    • pp.114-122
    • /
    • 1997
  • 본 연구에서는 계량 설비에 사용되는 스마트형 디지털 로드셀을 개발하였다. 로드셀 센서는 중량의 변화에 대해 매우 민감하여햐 하므로 정밀한 A/D변환을 위하여 온도 안정성, 낮은 드리프트 특성 그리고 분해능이 우수하여야 한다. 단일칩 마이크로프로세서에 의해 제어되는 고안된 아날로그 회로로써 OP엠프 오프셋과 드리프트 특성을 저감시키며 소프트웨어 알고리즘에 의해 안정되고 정밀한 A/D 변환이 가능하도록 디지털 로드셀을 설계하였다. 또한 RS-485통신 방식으로 로드셀을 제어하고 보정용 데이터와 제어 데이터를 기억시키는 기능들도 포함하였다. 시뮬레이션과 실측 평가를 통하여 개발된 로드셀의 우수성을 입증하였으며, 본 연구의 결과는 원격계량 센서로서 계량 설비 분야에 유용한 활용이 기대된다.

  • PDF