• 제목/요약/키워드: Load measurement

검색결과 1,664건 처리시간 0.035초

부하 불평형율에 대한 새로운 해석 (A New Analysis for Load Unbalance Factor)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.67-72
    • /
    • 2006
  • Most of the load distributions in low voltage power feeder distribution systems are designed with approximately balanced and connected at the three phase four wire systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating load unbalance. Load unbalance factor is mainly affected by the impedance of load system. Unbalanced current will draw a highly unbalanced voltage. This paper presents a new calculation method for unbalance factor under the load variation at the three phase four wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared with the current unbalance factor. Two methods are indicated similar results.

대구경 현장타설말뚝에 대한 변형봉 센서의 현장적용성에 관한 연구 (A Study on Field Application of a Deformable Rod Sensor to Large Diameter Drilled Shafts)

  • 정성기;김상일;정성교;최용규;이민희
    • 한국지반공학회논문집
    • /
    • 제19권6호
    • /
    • pp.15-22
    • /
    • 2003
  • 강관 내부 속채움한 현장타설말뚝에 대한 기존의 하중전이 측정에서는 강관의 변형률만 측정하고 콘크리트의 변형률은 강관과 동일하다고 가정하였으며, 시방서에 규정한 방법으로 구한 강관과 콘크리트의 탄성계수를 이용하여 말뚝 구성부재의 응력 및 축하중을 산정하였다. 그러나 강관의 변형률만 측정하여 강관과 콘크리트가 완전합성 거동하는 것으로 산정한 축하중은 실제 하중값과 상당한 차이를 보이고 있어 강관 내부 속채움한 현장타설말뚝의 거동을 정확히 분석할 수 없었다. 본 연구에서는 현장에서 제작한 콘크리트 공시체의 압축강도 시험을 통하여 탄성계수를 구하고 강재와 콘크리트의 변형률을 각각 측정할 수 있는 변형봉 센서를 이용하여 새로운 말뚝축하중 측정 방법을 제안하였다. 변형봉 센서를 사용하여 말뚝축하중을 산정할 경우 콘크리트의 탄성계수는 현장에서 제작한 콘크리트 공시체의 압축강도 시험에서 구하였으며, (0.2-0.6)$f_{ck}$의 응력 범위에 해당하는 평균접선기울기를 탄성계수로 사용하였다. 세 개의 현장타설말뚝에 대해 수행된 하중전이 측정 실험 결과를 이용하여 현장 적용성을 확인하였다. 변형봉 센서의 적용성은 대구경 현장타설말뚝에 대한 축하중 분포도를 통하여 확인하였는데, 말뚝머리에서 계산된 하중은 강관 내부속채움한 현장타설말뚝의 경우 실제작용하중에 비하여 -11∼-16% 오차를 나타내었으며, 현장타설 철근콘크리트말뚝의 경우 3.4% 오차를 나타내었다.

저전력 내장형 시스템을 위한 부하의 전력 소모 에뮬레이션 시스템과 응용 (A Load Emulator for Low-power Embedded Systems and Its Application)

  • 김관호;장래혁
    • 전자공학회논문지SC
    • /
    • 제42권6호
    • /
    • pp.37-48
    • /
    • 2005
  • 내장형 시스템의 DC-DC 변환기나 배터리의 효율은 시스템을 구성하는 디바이스들의 종류 및 다양한 동작 패턴에 따른 전류의 시간적인 변화에 영향을 받는다. 이러한 특성은 DC-DC 변환기나 배터리의 효율을 분석하기 위해서는 다양한 부하를 가지는 실제 시스템을 구현, 응용프로그램을 수행하고, 배터리와 DC-DC 변환기를 포함한 전원 공급 회로를 연결하여 실제로 전력 소모를 측정할 것을 요구하지만, 이와 같이 실제 시스템을 구현한다는 것은 엄청난 개발 시간과 비용을 요구한다. 본 논문에서는 부하들의 전력 소모를 측정에 의해 얻어 저장하고 전원 공급 회로로부터 실제 시스템의 부하처럼 전력을 소모하도록 에뮬레이션 해줄 수 있는 시스템을 구현하였다. 구현한 부하 에뮬레이터(load emulator)는 측정한 전력 소모 프로파일의 양을 줄이기 위해 패턴 인식 후 압축하는 알고리즘을 사용하며, 저속 대용량 능동부하(active load)와 고속 소용량 능동부하들로 이루어진 비대칭(heterogeneous) 구조로 구현함으로써 전력 소모의 양이 많고 전력 소모가 신속하게 변하는 디지털 시스템의 부하를 에뮬레이션 할 수 있게 해준다. 구현한 부하 에뮬레이터의 성능을 평가하기 위해 하드디스크의 전력 소모를 측정 및 재생하여 비교하며, 부하 에뮬레이터의 응용으로써 부하의 전력 소모 패턴에 따른 DC-DC 변환기의 효율을 검토해 보았다.

SA508-3재의 제하컴플라이언스법과 하중비해석을 이용한 파괴저항곡선 평가 (J-R Curve Characterization by Load Ratio Analysis and Unloading Compliance Method for SA508 C-3 steel)

  • 임만배;차귀준;윤한기;안원기
    • 한국해양공학회지
    • /
    • 제12권1호
    • /
    • pp.65-75
    • /
    • 1998
  • The fracture resistance curve is one of most important and design techniques employed in nuclear pressure vessel structures. This study is to evaluate the J-R curve characteristics for the SA508C-3 by the unloading compliance method and load rato analysis. The effect of strain aging for the exponential correlation of the J-R curve in this metal are investigated at room temperature, 20$0^{\circ}C$ and 30$0^{\circ}C$. The load ratio analysis method can evaluate the J-R curve by using the simple tension load-displacement curve only without the repeat of the unloading and loading. Therefore, the analysis by the proposed load ratio method has a merit, in comparison with the unloading compliance method, which can measure the crack length without the precision measurement equipment.

  • PDF

과전류 부하에서 5상 농형 유도전동기의 정수 특성 (Parameters Estimation Characteristics of Five-Phase Squirrel-Cage Induction Motor within Over Current Load)

  • 김민회
    • 조명전기설비학회논문지
    • /
    • 제29권7호
    • /
    • pp.38-46
    • /
    • 2015
  • This paper propose a variable parameter estimations for variable over current load of five-phase squirrel-cage induction motor(IM) to servo control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, torque command of current components, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental within variable over current load at rated input frequency. There are results of stator winding measurement, no-load test, locked-rotor test, variable over current load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

부하모델링을 위한 22.9[kV]모선의 계절별 부하특성에 관한 연구 (Seasonal Load Characteristics on 22.9[tV] Bus for Load Modeling)

  • 지평식;이종필;임재윤;김기동;박시우;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.304-306
    • /
    • 2000
  • Load modeling, micro method, needs field test to identify the validity of methodology applied to modeling. This paper presents seasonal field test method and measurement results on serveral substations. Seasonal load characteristics were analyzed by the developed substation load model and correlation coefficients of seasonal load of substation under base, peak and average load time.

  • PDF

배전용 변압기 부하사용 패턴분류 (Pattern Classification of Load Demand for Distribution Transformer)

  • 윤상윤;김재철;이영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.89-91
    • /
    • 2001
  • This paper presents the result of pattern classification of load demand for distribution transformer in domestic. The field data of load demand is measured using the load acquisition device and the measurement data is used for the database system for load management of distribution transformed. For the pattern classification, the load data and the customer information data are also used. The K-MEAN method is used for the pattern classification algorithm. The result of pattern classification is used for the 2-step format of load demand curve.

  • PDF