• 제목/요약/키워드: Load fluctuation

검색결과 271건 처리시간 0.027초

비정상연소의 특성과 연소진동 평가 (Evaluation on Characteristics of Unsteady Combustion and Combustion Oscillation)

  • 양영준
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.125-130
    • /
    • 2011
  • The characteristics of unsteady combustion were experimentally investigated using confined premixed flames stabilized by a rearward-facing step. The unsteady combustion used in this experiment plays an important role in controlling self-excited combustion oscillations and it has usually desirable performance such as high load combustion and low pollutant emission. It is known that combustion oscillation is occurred if Rayleigh's criterion is satisfied. The pressure fluctuation and OH-emission fluctuation were measured using pressure transducer and OH optical fiber respectively and then cross-corelation and phase difference were calculated to apply Rayleigh's criterion.

BESS 모델링 및 전기철도 급전계통에의 전압보상 적용 (BESS Modeling and Application to Voltage Compensation of Electric Railway System)

  • 유형준;손호익;김학만
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.417-423
    • /
    • 2013
  • The load of electric railroad can generate voltage fluctuation in the electric railway system because of high speed of the electric railroad and frequent movement and stop. This voltage fluctuation of electric railway system can cause not only voltage imbalance but also harmonic in the utility grid. Therefore the electric railroad system is in need of the reactive power compensation, such as static synchronous compensator (STATCOM) and static var compensator (SVC). Especially, the battery energy storage system (BESS) can control the real and reactive power at the same time. In this paper, the electric railway system using BESS has been modeled to show its voltage compensation effect using Matlab/Simulink.

전압변동 측면에서 본 아크로 부하가 전력계통에 미치는 영향 검토 (Analysis of effects of the arc-funace on the power system from the viewpoint of voltage regulation)

  • 박현택;김재철;박경호;임상국
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.366-369
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load. The simulated results show that the fluctuation of bus voltage adjacent the arc-furnace was varied from $4.3%{\sim}7.8%$ the normal voltage because of reactive power consumption by arc-furnace. Therefore, we expect this study will come into use as the basic information on the probability of the demand control

  • PDF

아크로 부하패턴을 고려한 전력계통 전압변동 분석 (Analysis of effects of the arc-funace on the power system Considering the toad pattern of arc-funace)

  • 박현택;김재철;손학식;임상국;오동환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.295-297
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load. The simulated results show that the fluctuation of bus voltage adjacent the arc-furnace was varied from $4.3\%\sim7.8\%$ the normal voltage because of reactive power consumption by arc-furnace. Therefore, we expect this study will come into use as the basic information on the probability of the demand control

  • PDF

콤바인 예취부 고장진단을 위한 예취 칼날부의 진단 시스템 개발(I) - 진동 및 부하 신호 분석 - (Development of Measurement System of Cutter Conditions for Combine Diagnosis (I) - Analysis of Vibration and Load Signals -)

  • 최창현;김용주;김종혁;문정환
    • Journal of Biosystems Engineering
    • /
    • 제32권3호
    • /
    • pp.190-196
    • /
    • 2007
  • The purpose of this study is to develop a measurement system of cutter conditions for combine header diagnosis during rice harvesting. A load cell was installed at the locker-arm to measure load fluctuation and an acceleration senor was used to monitor vibration signal of cutter bar. The data were collected from a paddy field during harvesting. The tests were conducted with a normal cutter, a loosened cutter, a broken cutter, and a worn-out connecter pin at the field. The vibration signals converted by FFT (Fast Fourier Transformation), filtered, and normalized. The load data and peak values of vibration signals in four different frequency ranges were used to determine the cutting operation and the cutter conditions of combine. The multiple comparison tests showed that the load data and peak values of vibration signals were important to monitor the cutting operation and cutter conditions of combine header.

Probabilistic Evaluation of Voltage Quality on Distribution System Containing Distributed Generation and Electric Vehicle Charging Load

  • CHEN, Wei;YAN, Hongqiang;PEI, Xiping
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1743-1753
    • /
    • 2017
  • Since there are multiple random variables in the probabilistic load flow (PLF) calculation of distribution system containing distributed generation (DG) and electric vehicle charging load (EVCL), a Monte Carlo method based on composite sampling method is put forward according to the existing simple random sampling Monte Carlo simulation method (SRS-MCSM) to perform probabilistic assessment analysis of voltage quality of distribution system containing DG and EVCL. This method considers not only the randomness of wind speed and light intensity as well as the uncertainty of basic load and EVCL, but also other stochastic disturbances, such as the failure rate of the transmission line. According to the different characteristics of random factors, different sampling methods are applied. Simulation results on IEEE9 bus system and IEEE34 bus system demonstrates the validity, accuracy, rapidity and practicability of the proposed method. In contrast to the SRS-MCSM, the proposed method is of higher computational efficiency and better simulation accuracy. The variation of nodal voltages for distribution system before and after connecting DG and EVCL is compared and analyzed, especially the voltage fluctuation of the grid-connected point of DG and EVCL.

건식 경량벽체의 내충격성 시험용 연질 충격체의 줄 길이에 따른 하중변동 특성 (Load Variation Characteristics about Rope Length of Large Soft Body of Lightweight Wall Impact Resistance test)

  • 김기준;송정현;안홍진;신윤호;지석원;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.182-183
    • /
    • 2014
  • In case of large soft body impact test at the construction site, the test conditions are different from conditions at the laboratory, and the length of rope to hold the impact specimen must be changed. In a previous study, the fact that the size of impact load is varied by the length of rope on the large soft body impact specimen was confirmed. In this study, the length of rope and fall height were set as independent variables to conduct the load analysis test. It was determined that the load fluctuation was occurred depending on the length of rope under the fall height over 100 mm, and it is concluded that the additional setup of fall height to modify the actual impact load size is required when the length of rope is below 2.5 m. In this study, the modified formula to put equal size of impact load regardless of the length of rope was extracted through the experiment.

  • PDF

유도가열기용 직.병렬 공진 고주파 인버터의 설계 (Design of High Frequency Inverter with Series-parallel Load-Resonant for Induction Heating application)

  • 홍순일;손의식
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.12-17
    • /
    • 2000
  • IN induction heating system the high frequency operation allows a rapid response to current fluctuation in the inverter and result in improved welding quality. To work induction heating of nonferrous metals, a welding power supply is need high working frequency and high power. This paper is shown design technique for increasing working frequency in induction heating for welding coppers. A series-parallel resonate inverter consists of H-type bridges, each of whose arms is composed of a combination of two parallel IGBTs. Inverter operating with the fixed frequency is controlled by pulse width modulation (PWM). As switching adapted the Zero-Voltage Switching technique to reduce switching losses the system is high efficiency. The propose inverter has feature which is high efficiency for very wide load variations with a narrow range of duty cycle ratio control and load short circuit capability. Detailed experimental results obtained from a 48[V] output, 500[W] experimental inverter are presented to verify the concept.

  • PDF

열환경챔버의 냉방 시뮬레이션 프로그램 개발에 관한 연구 (A Study on the Development of Cooling Simulation Program for Thermal Environmental Chamber)

  • 이한홍
    • 한국생산제조학회지
    • /
    • 제8권5호
    • /
    • pp.108-114
    • /
    • 1999
  • The thermal environmental chamber has been using in maintaining weather condition keeping thermal capacity under heating and cooling load fluctuation and for the performance testing of cooling system or air-conditioner on artificial envi-ronment. In ordder to make the various environmental conditions in the thermal environmental chamber the proper cooling system is necessary to eliminate the heating load produced inside the chamber and to maintain the designed environmental condition. For this reason the optimal design of cooling system and the prediction of performance is also required. This paper describes the prediction of performance of cooling system in the thermal environmental chamber with the capacity of 37,000kcal/hr which is developed for the test of performance in heating mode of heat pump system, In the results this paper is trying to develop simulation program on the base of mathematical models and which can be applied effectively to the optimal design of cooling system and prediction of performance to the inside and outside change of envi-ronmetal load.

  • PDF

Cycle-to-Cycle Fluctuations in a Spark Ignition Engine at Low Speed and Load

  • Han, Sung Bin;Hwang, Sung Il
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.205-210
    • /
    • 2013
  • Cycle-to-cycle variation has long been recognized as limiting the range of operating conditions of spark ignition engines, in particular, under lean and highly diluted operation conditions. At a part load, some of the cycles tend to knock, while others may have incomplete combustion by the time the exhaust valve opens. An experimental study has been performed in order to evaluate the relative contribution of several relevant parameters on the cyclic variability in spark ignition engines. In general, the stability of engine operation is improved with fuel injector according to the optimal injection timing, but the stability of engine operation at idle is not improved compared with a practical gasoline engine. In this study, we investigated the relationship of the effect of operating conditions for the stability at low speed and load.