• 제목/요약/키워드: Load capacitance

검색결과 159건 처리시간 0.027초

Efficient Pre-Bond Testing of TSV Defects Based on IEEE std. 1500 Wrapper Cells

  • Jung, Jihun;Ansari, Muhammad Adil;Kim, Dooyoung;Park, Sungju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권2호
    • /
    • pp.226-235
    • /
    • 2016
  • The yield of 3D stacked IC manufacturing improves with the pre-bond integrity testing of through silicon vias (TSVs). In this paper, an efficient pre-bond test method is presented based on IEEE std. 1500, which can precisely diagnose any happening of TSV defects. The IEEE std. 1500 wrapper cells are augmented for the proposed method. The pre-bond TSV test can be performed by adjusting the driving strength of TSV drivers and the test clock frequency. The experimental results show the advantages of the proposed approach.

궤환선형화 기법을 이용한 PWM 컨버터의 순시전압 제어 (Instantaneous Voltage Control of PWM Converters Using Feedback Linearization)

  • 이지명;이기도;이동춘
    • 전력전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.175-183
    • /
    • 1999
  • PWM 컨버터에서 직류출력전압의 빠른 응답을 위해 입력 및 출력의 전력평형개념을 시스템 모델링에 도입하는 것이 바람직하다. 이 경우 시스템은 비선형이 되며 제어기 설계가 용이하지 않다. 본 논문에서는 입출력 궤환선형화 기법을 응용하여 시스템의 비선형성을 제거하였으며 그 결과 빠른 전압응답특성을 얻을 수 있었다. 또한 작은 용량의 전해커패시터를 사용하더라도 부하변동에 대해 직류출력전압을 일정하게 유지하는 것이 가능함을 보였다.

  • PDF

넓은 입력전압 범위에서 동작하는 비대칭 하프브리지 방식의 플라이백 컨버터 (Asymmetrical Half-bridge Flyback Converter with Universal Input Voltage Range)

  • 유두희;이재민;정강률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.124-126
    • /
    • 2007
  • This paper presents an asymmetrical half-bridge flyback converter with universal input voltage range. The leakage inductance and output capacitance of active switches are used to realize zero voltage switching(ZVS) operation during the transition state between two switches. In this paper, the operating principle and system analysis of the adopted converter are discussed in detail. A 5V/20A prototype has been implemented to verify the proposed topology and theoretical operation under various load condition and universal input voltage range.

  • PDF

직류 평활용 전해 커패시터 노화 평가 (Ageing evaluation of electrolytic capacitor for dc-link)

  • 이성희;이진희;이치환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.634_635
    • /
    • 2009
  • Large aluminium electrolytic capacitors are widely used in inverter systems for smoothing dc-link voltage. If capacitors in dc-link are deteriorated by ageing, dc-link voltage is fluctuated by lessened capacitance and their bodies are heated by raised ESR(equivalent serial resistance) and finally system faults can be occurred. In this paper, on-load ageing test method of electrolytic capacitor in inverter system is proposed and test results are shown.

  • PDF

스위칭 소자의 전력 스트레스를 제거하기 위한 BUCK DC-DC 컨버터 (BUCK DC-DC Converter to Reduce Power Stress of Switching Device)

  • 이성백;박진홍
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권6호
    • /
    • pp.54-61
    • /
    • 1996
  • 본 논문에서는 기존에 제시된 영전압 준공진 buck dc-dc 컨버터를 시뮬레이션을 이용하여 분석하고, 이에서 발생하는 문제점을 분석하였다. 그리고 부하저항을 낮게 가변함에 따라 소자의 스트레스가 증가함을 확인하였다. 그 원인이 freewheeling다이오드의 기생 커채시턴스에 의한 전압상승에 의하여 발생함을 확인하고, 이를 개선할수 있는 영전압 스위칭 컨버터를 제시한다.

  • PDF

가포화 자기스위치를 이용한 탈황탈질 시스템의 전원장치에 관한 연구 (A study on topology of the DeNOx, DeSOx using magnetic pulse compressors)

  • 김수홍;이용덕;김승모;김병섭;권병기;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.157-159
    • /
    • 2008
  • Generally, Capacitor charging power supply (CCPS) consist of the full-bridge inverter, LC resonant tank and capacitance load. The multi-connection systems are normally used for high voltage or high power application. In this paper, conventional parallel operation resonant type and proposed series operation PWM type CCPS for pulse corona occurrence of DeSOx, DeNOx system using magnetic pulse compressor make a comparison. The effect of proposed CCPS is verified by circuit characteristics analysis of parallel operation resonant type and series operation PWM type, and it is confirmed by simulation result.

  • PDF

HVDC 단에 연결된 동기기의 여자시스템 스트레스 (Excitation System Stress in Synchronous Machine Connected to HVDC System)

  • 김찬기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권8호
    • /
    • pp.482-492
    • /
    • 2002
  • This paper deals with overvoltage stresses in the field circuit of synchronous machine connected to HVDC terminal. A load rejection of the HVDC may cause generator in the station to become self-excited, resulting in a severe system overvoltage. This paper shows that violent field current oscillations can be produced by resonance between the machine inductance and the terminal capacitance. As most conventional excitation system do not allow reverses current, new topology of excitation system to allow reverse current is proposed. the proposed system can limit the rate of rise of terminal voltage during conditions of self excitation. Apart from these simulations, the nature(Magnitude and frequency) of the field transient state is explained mathematically. Finally, the EMTDC program is used for the simulation studies.

중성점 전류 리플을 고려한 3-레벨 인버터의 공간 벡터 펄스폭 변조 기법 (A SVPWM for the Small Fluctuation of Neutral Point Current in Three-level Inverter)

  • 김래영;이요한;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.33-37
    • /
    • 1998
  • For the high power variable speed applications, the DCTLI(diode clamped three-level inverter) have been widely used. This paper describes the analysis of the neutral point current of the DCTLI and the improved space vector-based PWM strategy considering the switching frequency of power devices, that minimizes the fluctuation of the neutral point current in spite of high modulation index region and low power factor. It contributes to decrease the capacitance of dc-link capacitor bank and to increase the neutral point voltage controllable region. Especially, even if second (or even) order harmonic is induced in load current (at this situation, is was investigated that the general control method can not suppress the neutral point voltage variation), this PWM can provide effective control method to suppress the neutral point voltage variation. Various simulation results by means of Matlab/Simulation are presented to verify the proposed PWM.

  • PDF

전력용 AlGaAs/GaAs HBT의 제작과 소신호 등가 회로 추출에 관한 연구 (A study on the fabrication and the extraction of small signal equivalent circuit of power AlGaAs/GaAs HBTs)

  • 이제희;우효승;원태영
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.164-171
    • /
    • 1996
  • We report the experimental resutls on AlGaAs/GaAs heterojunction bipolar transistors (HBTs) with carbon-doped base structure. To characterize the output power, load-pull mehtod was employed. By characterizing the devices with HP8510C, we extracted the small-signal equivalent circuit. The HBTs were fabricated employing wet mesa etching and lift-off process of ohmic metals. the implementation of polyimide into the fabriction process was accomplished to obtain the lower dielectric constant resultig in significant reduction of interconnect routing capacitance. The fabricated HBTs with an emitter area of 6${\times}14{\mu}m^{2}$ exhibited current gain of 45, BV$_{CEO}$ of 10V, cut-off frequency of 30GHz and power gain of 1 3dBm. To extract the small signal equivalent circuit, the de-embedded method was applied for parasitic parameters and the calculation of circuit equations for intrinsic parameters.

  • PDF

인덕턴스형 미소 변위 측정 시스템과 응답 특성의 분석 (An Inductive Micro Position Sensign System and Analysis of its Response Characteristics)

  • 최동준;최인묵;김수현
    • 한국정밀공학회지
    • /
    • 제18권3호
    • /
    • pp.189-194
    • /
    • 2001
  • This paper presents a mew design of an inductive position sensing system with high sensitivity. The designed system consists of the driving coils, position-detecting coils, and closed loop formed magnetic blocks. To obtain high sensitivity we design a symmetric and closed loop type measuring system with small air-gaps. The elements that affect the system characteristics are turn ratio, excitation frequency, air-gap size, capacitance effect, and load resistance. By experimental investigation, the influences of these elements are examined and the system parameters are selected. The sensitivity of the newly designed system is greater than 2800mV/(V mm) and the linearity error is below${\pm}0.01%; in; the; range; of; {\pm}200{\mu}m$.

  • PDF