• Title/Summary/Keyword: Liquid storage tank

Search Result 210, Processing Time 0.032 seconds

The maintenance record of the KSTAR helium refrigeration system

  • Moon, K.M.;Joo, J.J.;Kim, N.W.;Chang, Y.B.;Park, D.S.;Kwag, S.W.;Song, N.H.;Lee, H.J.;Lee, Y.J.;Park, Y.M.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.6-9
    • /
    • 2013
  • Korea Superconducting Tokamak Advanced Research (KSTAR) has a helium refrigeration system (HRS) with the cooling capacity of 9 kW at 4.5 K. Main cold components are composed of 300 tons of superconducting (SC) magnets, main cryostat thermal shields, and SC current feeder system. The HRS comprises six gas storage tanks, a liquid nitrogen tank, the room temperature compression sector, the cold box (C/B), the 1st stage helium distribution box (DB#1), the PLC base local control system interconnected to central control tower and so on. Between HRS and cold components, there's another distribution box (DB#2) nearby the KSTAR device. The entire KSTAR device was constructed in 2007 and has been operated since 2008. This paper will present the maintenance result of the KSTAR HRS during the campaign and discuss the operation record and maintenance history of the KSTAR HRS.

Numerical Formulation of Axisymmetric Shell Element and Its Application to Geotechnical Problems (축대칭 쉘 요소의 유한요소 수식화와 지반공학적 활용)

  • Shin, Hosung;Kim, Jin-Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.12
    • /
    • pp.27-34
    • /
    • 2020
  • Use of axisymmetric shell element for the structure increases the efficiency and accuracy in finite element analysis of the interaction between the ground and the structure. This paper derived the force balance equation and the moment balance equation for an axisymmetric shell element based on Kirchhoff's theory. The governing equation for the axial deformation used the isoparametric shape function in the Galerkin formulation, and the governing equation for the shell bending used the higher-order shape function. The developed axisymmetric shell element was combined with Geo-COUS, a geotechnical finite element program for the coupled analysis with the ground. The accuracy of the developed element was confirmed through the example analyses of the circular plate and the liquid storage tank. And the energy balance equation for the axisymmetric shell element is presented.

Numerical simulation of air discharged in subcooled water pool

  • Y. Cordova ;D. Blanco ;Y. Rivera;C. Berna ;J.L. Munoz-Cobo ;A. Escriva
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3754-3767
    • /
    • 2023
  • Turbulent jet discharges in subcooled water pools are essential for safety systems in nuclear power plants, specifically in the pressure suppression pool of boiling water reactors and In-containment Refueling Water Storage Tank of advanced pressurized water reactors. The gas and liquid flow in these systems is investigated using multiphase flow analysis. This field has been extensively examined using a combination of experiments, theoretical models, and Computational Fluid Dynamics (CFD) simulations. ANSYS CFX offers two approaches to model multiphase flow behavior. The non-homogeneous Eulerian-Eulerian Model has been used in this work; it computes global information and is more convenient to study interpenetrated fluids. This study utilized the Large Eddy Simulation Model as the turbulence model, as it is better suited for non-stationary and buoyant flows. The CFD results of this study were validated with experimental data and theoretical results previously obtained. The figures of merit dimensionless penetration length and the dimensionless buoyancy length show good agreement with the experimental measurements. Correlations for these variables were obtained as a function of dimensionless numbers to give generality using only initial boundary conditions. CFD numerical model developed in this research has the capability to simulate the behavior of non-condensable gases discharged in water.

Practical Radiation Safety Control: (II) Application of Numerical Guidance for the Discharges of Radioactive Gaseous and Liquid Effluents (방사선안전관리 실무: (II) 배기중 및 배수중 배출관리기준의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.61-64
    • /
    • 2014
  • Radioactive materials are in use and have many applications from the generation of electricity to the purposes of research, industry and medicine such as diagnosis and therapy. In the course of their use some of radioactive substances may be discharged into the environment from facilities using the unsealed radioactive materials, which are main artificial sources occurring the public exposure. Discharges are in the form of gases, particles or liquids. This paper provides procedures to estimate the level of the public exposure based on the conservative assumptions and simple calculations in the facility using unsealed liquid sources. They consist of two processes; (1) to calculate maximum concentration of gaseous effluents discharged through the exhaust pipe and average concentration of liquid effluents discharged through the drain of the storage tank, (2) to compare each of them to numerical guidances for the discharges of radioactive gaseous and liquid effluents mentioned in the related notification. For this purpose followings are assumed properly; daily usage, form and dispersion rate of radionuclides, daily amount of radioactive liquid waste and exhaust and drainage equipment. The procedures are readily applicable to evaluate environmental effects by planned effluent discharges from facilities using the unsealed radioactive materials. In addition they may be utilized to obtain practical requirements for radiation safety control necessary for the reductions of the public exposure.

Effects of Enzyme Complex on Odor Emission from Swine Slurry and Swine Buildings (효소복합체가 양돈슬러리 및 돈사 악취발생에 미치는 영향)

  • Jung, K.H.;Han, J.C.;Kwack, S.J.;Jung, J.D.;Lee, J.W.;Kim, D.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2008
  • This study was carried out to investigate the effect of enzyme complex on odor emission from swine slurry and the process of making swine liquid manure. Ammonia and hydrogen sulfide concentrations were significantly decreased by using the enzyme complex of liter per ton level of liquid swine slurry in the manure storage tank according to the time. Characteristics of liquid swine slurry were affected by the enzyme complex, total nitrogen and ammonia nitrogen contents were reduced compare with control. Ammonia and hydrogen sulfide concentrations in the finishing pig building and offensive odor compound on the boundary line of swine farm were significantly decreased by spraying in swine finishing building. In conclusion, the results obtained from this study suggest that using the enzyme complex of liter per ton level of liquid swine slurry for making liquid swine manure may improve the quality of swine liquid fertilizer and reduce odor emission. Also farm scale enzyme complex treatment may improve air quality in finishing pig building and deduce offensive odor compound of swine farm.

  • PDF

Field Survey on Liquid Manure Utilization in the Agricultural Farms (경종농가에서의 액비이용 실태조사)

  • Choi D. Y.;Kwag J. H.;Park C. H.;Jeong K. H.;Jeon B. S.;Choi H. C.;Kang H. S.;Yang C. B.;Choi H. L.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.3
    • /
    • pp.155-162
    • /
    • 2004
  • The livestock liquid manure is one of important source for production of friendly environmental crops and have been used widespreadly in recent years. This survey is to eventually investigate the actual conditions of liquid manure utilization for cultivation of crops in the agricultural farm, based on the survey for 61 selected farms in 8 provinces(except Jeju province) included 22 counties in Korea. The results obtained in this survey were summarized as follow; $72.1\%$ of liquid manure storage tank(44) was located in the farmland and $27.9\%$(17) was in the fm. Most of liquid manure tank volume and material were 200 M/T($67.2\%$) and Polyethylene Double Frame panel($44.3\%$). The pro-portions of liquid manure application land were $45.9\%$ for rice paddy, $36.1\%$ for dry field, $16.4\%$ for orchard and $1.6\%$ for other, respectively. The controversial points of liquid manure utilization were malodor($60.7\%$), equipment possession($22.9\%$), no problem($13.1\%$) and farmland possession ($2.3\%$), respectively.

  • PDF

Damage Effects Modeling by Chlorine Leaks of Chemical Plants (화학공장의 염소 누출에 의한 피해 영향 모델링)

  • Jeong, Gyeong-Sam;Baik, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.76-87
    • /
    • 2018
  • This study describes the damage effects modeling for a quantitative prediction about the hazardous distances from pressurized chlorine saturated liquid tank, which has two-phase leakage. The heavy gas, chlorine is an accidental substance that is used as a raw material and intermediate in chemical plants. Based on the evaluation method for damage prediction and accident effects assessment models, the operating conditions were set as the standard conditions to reveal the optimal variables on an accident due to the leakage of a liquid chlorine storage vessel. A model of the atmospheric diffusion model, ALOHA (V5.4.4) developed by USEPA and NOAA, which is used for a risk assessment of Off-site Risk Assessment (ORA), was used. The Yeosu National Industrial Complex is designated as a model site, which manufactures and handles large quantities of chemical substances. Weather-related variables and process variables for each scenario need to be modelled to derive the characteristics of leakage accidents. The estimated levels of concern (LOC) were calculated based on the Gaussian diffusion model. As a result of ALOHA modeling, the hazardous distance due to chlorine diffusion increased with increasing air temperature and the wind speed decreased and the atmospheric stability was stabilized.

A Study on Damage Analysis Safety Distance Setting for LPG BLEVE (LPG BLEVE 피해분석 및 안전거리 설정에 관한 연구)

  • Kim, Jonghyuk;Lee, Byeongwoo;Kim, Jungwook;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.25-31
    • /
    • 2020
  • Boiling Liquid Expanding Vapor Explosion(BLEVE) can cause not only economic damage to the plant but also serious casualties. LPG accidents account for 89.6 percent of all accidents caused by gas leaks in Korea over the past nine years, while casualties from accidents also account for 73 percent of all accidents, according to statistics from the Korea Gas Safety Corporation. In addition, a potential explosion and a fire accident from one LPG storage tank may affect the nearby storage tanks, causing secondary and tertiary damage (domino effect). The safety distance standards for LPG used by LPG workplaces, charging stations, and homes in Korea have become stricter following the explosion of LPG charging stations in Bucheon. The safety distance regulation is divided into regulations based on the distance damage and the risk including frequency. This study suggests two approaches to optimizing the safety distance based on the just consequence and risk including frequencies. Using the Phast 7.2 Risk Assessment software by DNV GL, the explosion overpressure and heat radiation were derived according to the distance caused by BLEVE in the worst-case scenario, and accident and damage probability were derived by considering the probit function and domino effect. In addition, the safety distance between LPG tanks or LPG charging stations was derived to minimize damage effects by utilizing these measures.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

An Experimental Study on the Improvement of Foam Fire-Extinguishing System's Mixing Ratios by Expanding the Cross Sectional Area of the Stock Solution Inhaling Piping (원액흡입배관 단면적 확장에 의한 포 소화설비 혼합비 개선에 관한 실험적 연구)

  • Yun, Ki-Jo;Jang, Kyung-Nam;Baek, Eun-Sun;Park, Bong-Rae;Park, Hee-Joog
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.30-37
    • /
    • 2013
  • The ultimate purpose of the present study is to secure a effective method for foam liquid discharge when the mixing ratio deviates from the permissible range due to a decrease in the bypass flow rate resulting from a decrease in the cross sectional area of the foam liquid piping ranging from the branching header of one foam proportioner to the branching headers of multiple branching foam fire-extinguishing systems in the region for fire extinguishing and then to the standpipe at the lower part of the storage tank when a fire occurred in a combustible tank. To this end, the cause of mixing ratio variations following changes in the flow rates of existing foam fire extinguishing systems was analyzed, methods for compensation for constant mixing ratios were investigated, and it was proved that metering orifice replacements that could expand the cross sectional area of the stock solution inhaling piping was the most effective way for the improvement of form fire extinguishing systems' mixing ratios through foam proportioner venturi, foam chamber orifice, and metering orifice replacement experiments.