• Title/Summary/Keyword: Linear Dynamic Range

Search Result 272, Processing Time 0.027 seconds

A Study on the Per-Channel CPCM Method by means of the 1-Bit Interpolation (1-Bit Interpolation을 이용한 Per-Channel CPCM부호화방식에 관한 연구)

  • 정해원;조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 1982
  • In this paper, a improved per-channel PCM Coder with 1-bit interpolation is proposed. The coder converts a telephone signal to 15-segments u-law PCM signal of a large dynamic range. The A/D conversion technique of the proposed converter requires a feedback loop around a quantizer operates at high speed, and a accumulater for accumulating the quantized values to provide PCM outputs. To obtain both linear and compressed PCM signals a improved table look-up method is presented. The operations of the proposed converter are certified through the experiments to be good. The experimental circuit comprises TTL logic gates, a resistive D/Z converter and a simple differential amplifier. From the results of the experiments, it is known that the proposed converter has many advantage to be adopted economically for per-channel onverter used in rural area service.

  • PDF

Dynamic Analysis of Position Control using Transverse Flux Linear Motor Drive System (영구자석 여자 횡축형 선형 전동기 구동 시스템을 이용한 위치제어의 동특성 해석)

  • Chea, Dae-Jik;Kim, Jong-Moo;Kang, Do-Hyun;Lim, Tae-Yun;Ahn, Ho-Gyun;Park, Seung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1146-1148
    • /
    • 2002
  • Highly precise position control is essentially required in stead/transient state in liner motor. The overall performance of position control system is depend on the accuracy of the position information and the performance of the speed controller in low speed range. In this paper, When Load is changed that the simulation results confirm the validity of the proposed estimation and control scheme, and Dynamic characteristics of the designed Transverse Flux Linear Motor are simulated and estimated using Matlab/simlunk.

  • PDF

Analysis for the Effect of the Misalignment of the Power Line from the Displacement Caused by the Ship Motion of the Main Propulsion System (선체운동에 의한 주추진계의 변위가 동력축의 축 어긋남에 미치는 영향 분석)

  • Han, Hyung-Suk;Lee, Kyung-Hyun;Cho, Heung-Gi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2012
  • Since the engine and reduction gear in a naval vessel are usually supported by the mounting system separately, the misalignment between the input shaft of the reduction gear and the output shaft of the engine should occur caused by ship motion. In this study, this misalignment is estimated from the linear static analysis assuming that the phase of movements of the engine and reduction gear at low frequency range is same and the dynamic effect is not affect to them. Through comparing the relative displacement of the engine and reduction gear calculated from linear static analysis to that from dynamic analysis as well as experiment, the assumption in this study could be verified.

Bilinear Modeling of Grade Change Operation in Paper Mills (지종교체 공정의 Bilinear 모델링)

  • Chu, Yeon-Uk;Yeo, Yeong-Gu;Gang, Hong
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2004.04a
    • /
    • pp.97-106
    • /
    • 2004
  • The paper making process itself is a typical nonlinear process with complicated dynamics. In the application of advanced control-methods especially for the grade change operations the nonlinear process is linearized to give suitable linear models to be used in the control strategies. However, the use of the linear model is limited within short range containing steady-state operating conditions for grade change operation. In this paper a bilinear model for the nonlinear grade change processes is presented. We can see that the dynamic behavior for grade change operations can be effective analyzed by using multivariable bilinear model.

  • PDF

Levitation Control Simulation of a Maglev Vehicle Considering Guideway Flexibility (가이드웨이 유연성이 고려된 자기부상열차 부상제어 시뮬레이션)

  • Han, Jong-Boo;Lim, Jaewon;Kim, Chang-Hyun;Han, Hyung-Suk;Kim, Sung-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.15-24
    • /
    • 2015
  • In magnetic levitation vehicles, the clearance between the magnet and track should be maintained within an allowable range through a feedback control loop. The flexibility of the guideway would introduce additional modes in the overall suspension system, resulting in dynamic interaction between the guideway vibration and the electromagnetic suspension control system. This dynamic interaction can be a serious problem, particularly at very low speeds or standstill, and may cause airgap instability. To optimize the overall system dynamics, an integrated dynamic model including mechanical and electrical parts and a flexible guideway as well as a control loop was developed. With the proposed model, airgap simulations at standstill were performed while varying the control gains, specifically with the aim of understanding the effects of gains of the PID controller on the airgap variation. The findings may be used to achieve a stable levitation controller design.

Emulator Circuit for a Flux Locked Loop for Detection of Magnetocardiography Signal (심자도 신호 검출을 위한 Flux Locked Loop (FLL) Emulation 회로)

  • 안창범;이동훈;김인기;장경섭;김기태;정동현;최중필
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2749-2752
    • /
    • 2003
  • Magnetocardiography is a very weak biomagnetic field generated from the heart. Since the magnitude of the biomagnetic field is in the order of a few pico Tesla, it is measured with a superconducting quantum interference device (SQUID). SQUID is a transducer converting magnetic flux to voltage, however, its range of linear conversion is very restricted. In order to overcome the narrow dynamic range. a flux locked loop is used to feedback the output field with opposite polarity to the input field so that the total Held becomes zero. This prevents the operating point of the SQUID from moving too far away from the null point thereby escape from the linear region. In this paper, an emulator for the SQUID sensor and feedback coil is proposed. Magnetic courting between the original field and the generated field by the feedback coil is emulated by electronic circuits. By using the emulator, FLL circuits are analyzed and optimized without SQUID sensors. The emulator may be used as a test signal for multi-channel gain calibration and system maintenance.

  • PDF

A Design of High Resolution Temperature Measurement System Using Digital Signal Processor (디지털 신호처리기를 이용한 고분해능 온도측정 시스템 설계)

  • Kim, Tae-Hoon;Lim, Ju-Hyun;Kim, Duck-Young;Ko, Han-Woo;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.317-322
    • /
    • 2002
  • This paper presents a linear temperature/voltage relation over a temperature range(0~100$^{\circ}C$) with high-resolution, reasonably god response linearity, reliability, and overall improved performance. A notable feature of the proposed method is that the whole temperature span is divided by 16 subbands thus the variation span of measured voltage is narrowed. Therefore noise characteristic has been improved. The output voltage is amplified after the uniformed DC voltage component is eliminated by offset. We proposed circuit using median value and mean value of digital signal in order to reduce the noise effect. The proposed circuit offers linear temperature/voltage conversion over a wide dynamic range using DSP(TMS320C31) and steinhart equation.

Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images (초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과)

  • Yang, Jeong-Hwa;Kang, Gwan-Suk;Lee, Kyung-Sung;Paeng, Dong-Guk;Choi, Min-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.277-283
    • /
    • 2009
  • It is important to get clinical ultrasonic images of good quality for accurate diagnosis. In this study, it observed the change of ultrasonic images against setting frequency, dynamic range(DR) and type of probes on ultrasonic scanner. In the experiment it evaluated image of LCS (Low Contrast Sensitivity) targets(-15, -6, -3, +3, +6, +15 dB) of a standard ultrasonic test phantoms(539,551, ATS, USA) similar to solid and cystic lesions. Its imaged from convex (C3-7IM) and linear probe (L5-12IM) on SA-9900 (Medison Ltd, Korea) scanner. The images obtained altering the setting parameters which are frequency(gen, pen, res, harmonic) mode and DR($40{\sim}100\;dB$). The quality of images evaluated compare with the nominal LCS value of target and measured LCS value. The results show that there was no significant changing of quality images altering DR 40, 60, 80, 100 dB against frequency in Convex probe but the image being the highest in LCS target at DR 60 dB, harmonic of frequency mode in the -15 dB target close to cystic lesion. In Linear probe, DR 40 dB, harmonic mode at -15 dB LCS target close to nominal value. It discussed necessity of evaluation about ROC(Receiver Operating Characteristic) from the psychological viewpoint and limit of evaluation from quantified images.

  • PDF

Testing and experimental characterization of a linear permanent magnet actuator for active vehicle suspension

  • Wang, Jiabin;Wang, Weiya
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.509-516
    • /
    • 2012
  • This paper describes the testing and experimental characterization of a linear permanent magnet actuator, which is designed and developed for active vehicle suspension, under both static and dynamic conditions. Since the active suspension unit operates over a wide force-velocity range with varying duty ratios, it is essential to establish an effective thermal model which can be used for assessing temperature rise of the actuator under various operating conditions. The temperature rise of the actuator is measured and the results are compared with the prediction by the derived transient thermal model. It is shown that the measured actuator parameters and characteristics are closed to their predicted values. The linear actuator is controlled by a dSPACE system via a three phase inverter and its velocity tracking performance is presented.

The Charcteristics Analysis of Linear Pulse Motor (선형 펄스 전동기의 특성 해석)

  • Jo, Yun-Hyeon;Lee, Gwang-Ho;Kim, Seong-Do
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.5
    • /
    • pp.249-256
    • /
    • 1999
  • This paper describes static characteristics analysis of linear pulse motor(LPM) with two permanent magnets. Linear pulse motors are finding a wide range of application for the Factory-Automation or the Office-Automation. Typically, LPM provides for a reliable and precise control of position, velocity, or acceleration without using a closed-loop system. Some of the advantages of LPMs are ease of control, step multiplication, static and dynamic positioning, and locking force. The flux density and thrust of LPM is computed by the FEM and magnetic equivalent circuits which considered the magnetic nonlinear phenomena. The result of characteristics analysis are shown as the flux, the air gap reluctance and the thrust. The velocity and position characteristics as a function of unit step input is measured. To estimate the unit step response charecteristic of LPM, the simulation results by Matlab and the experimental results is compared.

  • PDF