• Title/Summary/Keyword: Line start permanent magnet motor

Search Result 64, Processing Time 0.028 seconds

A study on the transient characteristics in Single-phase Line-start Permanent Magnet (단상 유도동기 전동기(LSPM)의 과도 특성에 관한 연구)

  • Jung, Dae-Sung;Lee, Ju;Ree, Cheol-Jick
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.631-632
    • /
    • 2006
  • This paper is written by research for the transient characteristics of the Single-phase Line-start permanent Magnet. The Single-phase Line-start permanent Magnet is most likely to substitute for Single-phase Induction Motor which is used about many appliance currently, because that has good points. For example, It has a Line-start of ability and a High-efficiency. And it need not power convergence device. The rotor of The Single-phase Line-start permanent Magnet has cage-bar with permanent magnet. This motor is started by cage-bar. When it entered synchronous condition, the rotor is rotated by the permanent magnet. But the design of the permanent magnet is very important, because the breaking torque of the permanent magnet interrupt to start a rotor. Finally, if Flux Barrier is not concerned, we do not get result of our object. Therefore this thesis is concerned about Flux Barrier.

  • PDF

Optimal Design for Starting -Torque of Line-Start Permanent Magnet Synchronous Motors (직립 기동 영구자석 동기전동기의 기동토크 최적화 설계)

  • Kim, Byong-Kuk;Moon, Ji-Woo;Kim, Mi-Jung;Lee, Byung-Jun;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1390-1396
    • /
    • 2007
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However, it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor. Finally this paper gives the comparison between the simulation results and the experimental results.

A Study on the Characteristics in Single-Phase Line-Start Permanent Magnet Moter (단상 유도형 동기 전동기(LSPM)의 특성해석에 관한 연구)

  • Jung, Dae-Sung;Kim, Seung-Ju;Lee, Jin-Hun;Choi, Jae-Hak;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.125-131
    • /
    • 2007
  • Electric motor efficient improvement from home appliance field is important to the effect reducing the energy consumption. But the electric motor design/analysis technology is still insufficient. Specially the electric motor design/analysis technology of satisfying characteristic of both the induction motor and the synchronous motor such as Line start permanent motor. Therefore the electric motor design/analysis technology is urgently demanded reliability. This paper proposes the sing1e-phase line-start permanent magnet motor to develop the motor it with be able to alternate the sing-phase induction motor it is a refrigerator compressor motor. The sing-phase induction motor is analyzed in the steady state. And we have a certification test to compare our single-phase line-start permanent magnet motor with the sing-phase induction motor. In order to improve the performance, the stator of the single-phase line-start permanent magnet motor is same as the stator of the sing-phase induction motor and changes the rotor form and has the permanent magnet. It used the Finite Element Method(FEM) which is widely used with electronic-magnetic field numerical analysis method.

The Application of Classical Direct Torque and Flux Control (DTFC) for Line-Start Permanent Magnet Synchronous and its Comparison with Permanent Magnet Synchronous Motor

  • Soreshjani, Mohsen Hosseinzadeh;Heidari, Reza;Ghafari, Ahmad
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1954-1959
    • /
    • 2014
  • This paper attempts to design and present a comparison of classical Direct Torque Flux Control (DTFC) for Line-Start Permanent Magnet Synchronous Motor (LSPMSM) and its equal Permanent Magnet Synchronous Motor (PMSM). In order to present an in-depth analysis, both motors for DTFC Voltage Source Inverter (VSI)-fed in the same situations of different conditions are simulated and tested. The advantages of the proposed method for LSPMSM over the PMSM are discussed and analyzed.

Dynamic Characteristic Analysis of Line-Start Permanent Magnet Synchronous Motor (직립 기동 영구자석 동기전동기의 동특성 해석)

  • Kim, Byong-Kuk;Jo, Won-Yung;Lee, In-Jae;Moon, Ji-Woo;Kim, Mi-Jung;Lim, Seong-Hwan;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.185-187
    • /
    • 2006
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

Optimal Design and Dynamic Characteristic Analysis of Line Start Permanent Magnet Synchronous Motor (직립 기동 영구자석 동기전동기의 최적설계 및 동특성 해석)

  • Kim, Do-Sun;Kim, Byong-Kuk;Lee, Byung-Jun;Cho, Youn-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.92-94
    • /
    • 2008
  • The interest in permanent magnet synchronous motor is present in a wide area of applications, ranging from high-performance servo drive to line-start application[1]. The are mainly two reasons for this trend: first low rotor losses and second the foiling prices of high-energy magnets. In this paper the dynamic characteristic of the line-start permanent magnet synchronous motor are described and compared with those if the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bar in the line-start permanent magnet synchronous motor.

  • PDF

Optimal Design for Starting-Torque of Line Start Permanent Magnet Synchronous Motor (직립 기동 영구자석 동기 전동기의 기동 토크 최적화 설계)

  • Kim, Byong-Kuk;Hwang, Dong-Won;Kim, Tae-Hyun;Jo, Won-Yung;Lee, In-Jae;Han, Sung-Jin;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.930-932
    • /
    • 2005
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

Character Analysis for Break-Torque of Line-Start Permanent Magnet Synchronous Motors (직립 기동 영구자석 동기 전동기의 브레이크 토크 특성 해석)

  • Kim, Byung-Kuk;Kim, Tae-Hyun;Jo, Won-Yung;Lee, In-Jae;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.86-88
    • /
    • 2005
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor arc described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

A study on the Rotor Design in Single-phase Line-start Permanent Magnet Motor (단상 유도형 동기전동기의 회전자 설계에 관한 연구)

  • Kim, Won-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • The purpose of this paper is the rotor design of a single-phase LSPM(Line-start permanent magnet) motor. A single-phase LSPM motor has a permanent magnet in the rotor that is same as induction motor. For that reason, magnet is operated by breaking torque in starting region and alignment torque in driving region. Therefore, we need the design process considering the trade-off relationship. In this paper, we propose the design process of a single-phase LSPM motor for a high starting torque and efficiency with FEM. And we use Taguchi Method for considering tolerance in manufacture. Finally, we compared the LSPM motor that is designed in this paper and conventional induction motor.

Comparison of the Single-phase Line-start Permant Magnet Motor's Transient Characteristics by Size and Position of Rotor Bar (영구자석 매입형 단상 유도 동기 전동기의 회전자 바의 크기와 위치에 따른 기동 특성 비교)

  • Kwon, S.H.;Yang, B.Y.;Kwon, B.I.;Lee, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.933-935
    • /
    • 2003
  • The single-phase line start permanent magnet motor(LSPM) have a rotor cage bar for induction starting and permanent magnets, providing synchronous torque. So, LSPM is vary complex and difficult to analysis transient characteristics and rotor design. In this paper, F.E.M analysis about single-phase line start permanent magnet motor and compare of the single-phase line start permanent magnet synchronous motor's transient characteristics by size and position of rotor bar.

  • PDF