• Title/Summary/Keyword: Line source method

Search Result 514, Processing Time 0.029 seconds

Directivity Synthesis Simulation of Ultrasonic Transducer Using Gauss Elimination Method (GAUSS 소거법을 이용한 초음파 트랜스듀서의 지향성합성 SIMULATION)

  • 이정남;조기량;이진선;이문수
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.4
    • /
    • pp.20-27
    • /
    • 1995
  • A numerical simulation is carried out on the directivity synthesis of ultrasonic transducers by point source array. Gauss elimination method is practiced by means of a directive method to realize the desired directivity. Desired directivity is chosen to be that of a directivity of line source, a beam width and a direction arbitrary specified. On the numerical result, Gauss elimination method is showed high speed ca- lculative simulation and stability of system more than iterative method(LMS, DFP). Numerical simulations are carried out by PC(CPU:80486 DX2, RAM 16Mbyte).

  • PDF

Signal Processing for Improvement of Resolution and Direction Ambiguity of Source in Line Array (선 배열에서 표적체의 방위 모호성과 분해능 향상을 위한 신호처리 기법)

  • 손윤준;천승용;김기만
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.482-488
    • /
    • 2003
  • Line may receiver contains an ambiguity on conjugate bearings, because of lacking aperture in transverse direction. To solve the left/right bearing ambiguity of line-array receiver we used line-array with cardioid beam. In addition, the synthetic aperture method adopts coherent processing of sub-aperture signals at successive time intervals in the beam domain. We presented performances about division of left/right bearing ambiguity according to array synthetic number of times in this paper.

A Study on the Optimum Line Heating Condition for Straightening a Thin Plate Welded Structure (박판재 용접 구조물의 선상 가열 교정에서 최적 조건의 선정에 관한 연구)

  • Park, Jun-Hyoung;Kim, Jae-Woong
    • Journal of Welding and Joining
    • /
    • v.29 no.2
    • /
    • pp.40-45
    • /
    • 2011
  • The purpose of this study is to establish the optimum line heating condition to straighten the excessive bending distortion of a thin plate welded structure. For it, the extensive FEA and experiments were performed to evaluate the effect of heat source, heating speed and position on the straightening of a thin plate welded structure. In accordance with the results obtained by FEA and experiments, the straightening effect of line heating was strongly depends on the variables used in this study. With the results, the optimum line heating condition was established by using the response surface method and verified through comparing it with the numerical analysis result.

An Analytic Solution to Projector Pose Estimation Problem

  • Lee, Joo-Haeng
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.978-981
    • /
    • 2012
  • We present an analytic solution to the projector pose estimation problem for the pinhole projection model in which the source image is a centered rectangle with an unknown aspect ratio. From a single quadrilateral given as a target image, our solution gives the position and orientation of a projector as well as the aspect ratio of a source image. The proposed method decomposes the problem into two pose estimation problems of coupled line projectors aligned at each diagonal of the given quadrilateral and then computes the common solution that satisfies the relevant geometric constraints. The solution is formulated as simple analytic equations. We also provide a determinant of projectability of an arbitrary quadrilateral.

A design for a robust active power filter in unbalanced and distortion source voltages in three-phase four-wire systems (전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계)

  • Min J.K.;Choi J.H.;Kim H.S.;Kim K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.729-733
    • /
    • 2003
  • This paper proposed a novel current control strategy on active power filters using p-q-r instantaneous power theory which can compensate the line current harmonics and the neutral line current in unbalanced and/or distorted source conditions in three-phase four-wire systems. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation which was compared with a hysteresis PWM. Simulation results showed good performance of the proposed current control strategy on shunt type APFs.

  • PDF

Fabrication of low-stress silicon nitride film for application to biochemical sensor array

  • Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.357-361
    • /
    • 2005
  • Low-stress silicon nitride (LSN) thin films with embedded metal line have been developed as free standing structures to keep microspheres in proper locations and localized heat source for application to a chip-based sensor array for the simultaneous and near-real-time detection of multiple analytes in solution. The LSN film has been utilized as a structural material as well as a hard mask layer for wet anisotropic etching of silicon. The LSN was deposited by LPCVD (Low Pressure Chemical Vapor Deposition) process by varing the ratio of source gas flows. The residual stress of the LSN film was measured by laser curvature method. The residual stress of the LSN film is 6 times lower than that of the stoichiometric silicon nitride film. The test results showed that not only the LSN film but also the stack of LSN layers with embedded metal line could stand without notable deflection.

Compensation of the rotor time constant of induction motor using current error feedback (전류오차 궤환을 이용한 유도전동기 회전자 시정수 보상)

  • 김승민;이무영;권우현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.195-198
    • /
    • 1997
  • This paper proposes the effective compensation method of the rotor time constant of induction motor. An indirect vector control method is highly dependent on the motor parameters. To solve the problem of performance degradation due to parameter variation in an indirect vector control of induction motor, we compensate the rotor time constant by current error feedback. The proposed method is a simple on-line rotor time constant compensation method using the information from terminal voltages and currents. As the current error, difference between current command and estimated current, approaches to zero, the value of rotor time constant in an indirect vector controller follows the real value of induction motor. This scheme is valid transient region as well as steady state region regardless of low or high speed. This method is verified by computer simulation. For this, we constructed the simulation model of induction motor, indirect vector controller and current regulated PWM (CRPWM) voltage source inverter (VSI) using SIMULINK in MATLAB.

  • PDF

Chaos Secure Communication using Chua Circuit with Equivalent Power Lines (등가 전력선을 가진 Chua 회로에서의 카오스 비밀통신)

  • 배영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.263-266
    • /
    • 2000
  • In this paper, we formed a transmitter and receiver by using two identical Chua's circuits and then formed wireless transmission line from the channel which was between those two circuits. We proposed a secure communication method in which the desired information signal was synthesized with the chaos signal created in a Chua's circuit and sent to the transmitter through channel. Then the signal was demodulated receiver of Chua's circuit. The method we used to accomplish the sun communication was synthesizing the desired information with the chaos circuit by parallel connection in a wireless transmission line. After transmitting the synthesized signal to the wireless transmission line, we confirmed the actuality of the secure communication by separating the information signal and the chaos signal in the receiver. In order to confirm the security, we compared the wiretapped signal and the recovery signal under the assumption that the wiretapping had taken place. In order to separate the two signals, we transformed the information signal to a current source in the transmitter and detected the current in the receiver.

  • PDF

Chaos Secure Communication Using Chua Circuit (Chua 회로에서의 카오스 비밀통신)

  • 배영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.238-241
    • /
    • 2000
  • In this paper, we formed a transmitter and receiver by using two identical Chua's circuits and then formed wireless transmission line from the channel which was between those two circuits. We proposed a secure communication method in which the desired information signal was synthesized with the chaos signal created in a Chua's circuit and sent to the transmitter through channel. Then the signal was demodulated receiver of Chua's circuit. The Method we used to accomplish the secure communication was synthesizing the desired information with the chaos circuit by parallel connection in a wireless transmission line. After transmitting the synthesized signal to the wireless transmission line, we confirmed the actuality of the secure communication by separating the information signal and the chads signal in the receiver. In order to confirm the security, we compared the wiretapped signal and the recovery signal under the assumption that the wiretapping had taken place. In order to separate the two signals, we transformed the information signal to a current source in the transmitter and detected the current in the receiver.

  • PDF

Development of the grounding monitoring system for intelligent buildings (정보화 건측물을 위한 접지감시시스템 개발)

  • Cha, Sung-Chul;Lee, Tae-Hyung;Earn, Ju-Hang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.196-197
    • /
    • 2006
  • An effective method is described for monitoring the ground impedance of intelligent building and power system. Most of grounding system of buildings are interconnected to extensive grounding network of power line, signal and control line, telecommunication line, and etc. Therefore, the residual voltages of power frequency and its harmonics may have an significant influence on the accurate measurement of ground impedance. For eliminating the influence of residual voltage, we developed a test power source for generating the 110[Hz] square wave and used digital filtering method in this research.

  • PDF