• 제목/요약/키워드: Line pressure

검색결과 1,571건 처리시간 0.032초

위상간섭을 이용한 사축식 액셜 피스톤 펌프의 압력 맥동 감소 (A Reduction in Pressure Ripples of Axial Piston Pumps of Bent Axis by Phase Interface)

  • 김경훈;박경석;장주섭;김봉환;이규원;손권;신민호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1261-1265
    • /
    • 2003
  • Axial piston pumps of bent axis have been commonly used in hydraulic systems because of high pressure level. best efficiency, low shear force on pistons and low operating costs. The other side, they have a few demerits like that they have the relatively high number of moving parts and more discharge pressure ripples. Especially, the discharge pressure ripples bring about vibrations and noises in hydraulic system components such as connecting pipes and control valves, so that these deteriorate the stability and accuracy of the systems. Therefore, the hydraulic systems having the axial piston pumps of bent axis require the methods to reduce the discharge pressure ripples. So, the purpose of this paper is to reduce the discharge pressure ripples by the phase interference of pressure wave and to develope the analysis model of the pumps to predict the discharge pressure ripples. In this paper, the analysis model of the axial piston pumps of bent axis was developed using the AMESim software, and the reliability of that was verified by the comparison with the experimental results. The hydraulic pipeline with a parallel line was used as the method to generate the phase interference of pressure wave. the dynamics characteristics of the hydraulic pipeline with a parallel line were analyzed by a transfer matrix method. the usefulness of the phase interference of pressure wave was investigated through the experiment and simulation. The results from the experiment and simulation said that the phase interference of pressure wave by the hydraulic pipeline with a paralle linel could reduce the discharge pressure wave of the pump well. The analysis model of the axial piston pumps of bent axis developed in this paper and the method of the phase interference by the hydraulic pipeline with a parallel line are expected to be helpful to achieve the design of the pump and to reduce the discharge pressure wave of the pump effectively.

  • PDF

화력 발전기 고정자 권선에서의 수소 압력에 따른 부분 방전 특성 (The Effect of Hydrogen Pressure on Partial Discharge Spectroscopy in Turbine Generator Winding Insulations)

  • 김진봉;황돈하;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1320-1325
    • /
    • 1995
  • For hydrogen-cooled large turbine generators, partial discharges in ground wall insulations are suppressed by high hydrogen pressure. The first goal of the experiment is to investigate the effect of hydrogen pressure on partial discharge activity and aging rate in turbine generator winding insulations. A series of tests have been performed on two groups of the accelerated aging experiments. The first group of stator windings was aged under hydrogen pressure of 4 atm while the second group of stator windings was aged under air atmosphere. The stator windings aged under air atmosphere suffer from larger partial discharge magnitude with larger voids at high electrical stress than those under hydrogen pressure. The second goal of the experiment is to evaluate the validity of on-line measurement technique which is normally measured under hydrogen environment. The test results show that further experiments are needed to apply the on-line scheme to turbine generator being under high hydrogen pressure.

  • PDF

고주파수 PWM제어를 이용한 ABS의 맥동 저감에 관한 연구 (A Study on Falling Pressure Surge of ABS Using High Frequency PWM Control)

  • 이용주;김병우;박호
    • 한국공작기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.38-44
    • /
    • 2003
  • The solenoid valve in ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz high speed pulse width modulation. When the valve is switched from open state to closed state, noise and vibration due to pressure surge phenomena in the hydraulic line and wheel cylinder are made. In this study, we identify Pressure surge phenomenon in the braking process of a ABS, and investigate the way to reduce the phenomenon. For the purpose of theoretical analysis on the pressure surge in the closed state hydraulic line, characteristic curve method based on wave equation was utilized. To reduce the surge, high frequency control of 20kHz was attempted. The result showed that the surge pressure of 50% was reduced compared to one observed in the low frequency control. Duty variation of high frequency can control current of solenoid valve and prevent sudden change of displacement.

Effect of static mixer geometry on flow mixing and pressure drop in marine SCR applications

  • Park, Taewha;Sung, Yonmo;Kim, Taekyung;Lee, Inwon;Choi, Gyungmin;Kim, Duckjool
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권1호
    • /
    • pp.27-38
    • /
    • 2014
  • Flow mixing and pressure drop characteristics for marine selective catalytic reduction applications were investigated numerically to develop an efficient static mixer. Two different mixers, line- and swirl-type, were considered. The effect of vane angles on the relative intensity, uniformity index, and pressure drop was investigated in a swirl-type mixer; these parameters are dramatically affected by the mixer geometry. The presence of a mixer, regardless of the mixer type, led to an improvement of approximately 20% in the mixing performance behind the mixer in comparison to not having a mixer. In particular, there was a tradeoff relationship between the uniformity and the pressure drop. Considering the mixing performance and the pressure drop, the swirl-type mixer was more suitable than the line-type mixer in this study.

냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향 (Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

선박적용을 위한 장주기 광섬유 격자 압력센서의 기초연구 (Basic Study on The Long-period Fiber Grating Pressure Sensor for applying the Vessels)

  • 손경락;최영길;장세인;최재윤
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.202-203
    • /
    • 2005
  • we present a pressure sensor based on the mechanically formed long-period fiber gratings. The attenuation properties of an output power as a function of an external pressure is able to apply to the in-line fiber pressure sensors for the vessels.

  • PDF

고혈압 치료 지침 Vl에 의한 항고혈압제의 사용평가 (Drug Use Evaluation of Antihypertensive Agents by JNC VI Guidelines)

  • 김경화;이숙향
    • 한국임상약학회지
    • /
    • 제12권1호
    • /
    • pp.29-38
    • /
    • 2002
  • Hypertension is an important public health problem because it increases the risk of stroke, angina, myocardial infarction, heart failure, and end-stage renal disease. If it is not actively treated, morbidity and mortality increase with hypertension-induced complications and quality of life decreases. This study was to evaluate the use of antihypertensive drugs and blood pressure changes and to compare algorithms chosen (or the 1st and 2nd line therapy of hypertension based on the JNC VI recommendations. The medical charts of 222 patients with essential hypertension at St. Vincent's Hospital in Suwon from January 1997 to January 2000 were reviewed retrospectively. Data collection and analysis included baseline BP underlying diseases and complications, administered antihypertensives, BP changes, changes of antihypertensive regimen, and adverse effects with treatments. As results, the higher BP the patients had, the more frequent they had target organ damages and clinical cardiovascular diseases. Mean duration to reduce blood pressure less than 140/90 mmHg was 8 weeks in $85.3\%$ of the patients. The rate of control in BP was $82.4\%$ at 6 months. The major antihypertensive drugs prescribed were calcium channel blockers $(61.8\%)$ , ACE inhibitors $(19.1\%),\;\beta-blockers\;(13.7\%)$ and diuretics $(5.3\%)$ as the 1st-line monotherapy. The methods of treatment used as the 1st-line therapy were monotherapy$(59\%)$ and combination therapy $(41\%)$. Blood pressure change was significantly greater for combination therapy than monotherapy$(-26.2\pm21.4\;vs.\;-18.56\pm16.7$ mmHg for systolic blood pressure; P<0.003, $-16.9\pm13.2\;vs.\;-9.2\pm12.8$ mmHg for diastolic blood pressure; p<0.001). When blood pressure was not completely controlled with the first antihypertensive selected, the 2nd line therapy had 4 options: addition of 2nd agent from different class; $66.2\%$, substitution with another drug, $21.9\%$ increase dose $11.9\%$ continue first regimen $27.9\%$ Calcium channel blockers were the most frequently prescribed agents. This was not comparable to the JNC VI guideline which recommended diuretics and $\beta-blockers$ for the 1st-line therapy. Most of patients achieved the goal BP and maintained it until 6 months, but the remaining patients should be controlled more tightly to improve their BP with combination of life style modification, patient education, and pharmacotherapy.

  • PDF

임베디드 시스템을 이용한 CVT 유압시스템 제어 (A Control of CVT Hydraulic System using Embedded System)

  • 한기원;류완식;장인규;전재욱;김현수;황성호
    • 유공압시스템학회논문집
    • /
    • 제4권1호
    • /
    • pp.18-24
    • /
    • 2007
  • The continuously variable transmission (CVT) of which speed ratio can change continuously in a fixed range has the benefits of low fuel consumption and exhaust gas because it enables the engine of a vehicle to operate in a high efficiency range regardless of vehicle speed. The speed ratio of belt type CVT is controlled by adjusting line pressure. The one of the line pressure control methods, mechanical-hydraulic control is usually adopting VDT's control method, in which the secondary solenoid valve has two functions both a regulator and a line pressure controller. However, this control method could not show the high performance of CVT with optimal driving capability because of the limitation of simple control algorithm, and it could not gain market share sufficiently in spite of the advantage of CVT with low fuel consumption. On the other hand, the electro-hydraulic control method gives the enhancement of power performance and low fuel consumption by implementing various driving mode using the proportional control or PWM control. The key of CVT technique is to develop a control algorithm of the electro-hydraulic solenoid valve in order to implement the speed ratio efficiently. In this paper, the line pressure control algorithm is proposed and the hydraulic system is controlled using metal belt type CVT test rig and the embedded ECU platform.

  • PDF

수소연료전지 차량 충전에서의 압력강하 분석 (Pressure Drop Analysis on Filling of Hydrogen Fuel Cell Vehicles)

  • 서효민;박병흥
    • 한국가스학회지
    • /
    • 제27권1호
    • /
    • pp.38-47
    • /
    • 2023
  • 수소연료전지 차량 충전 과정에서, 충전소에서의 공급압력과 차량 내 저장 탱크의 압력 차이에 의해 수소가 흐르게 되고 유량은 압력 차에 의존한다. 따라서 충전 과정에서 발생하는 수소의 압력강하에 대한 고려는 필수적이며 이의 분석을 통해 수소 충전 과정의 효율성을 높일 수 있다. 본 연구에서는 충전라인 중 호스, 노즐/리셉터클, 파이프, 밸브에 대하여 압력강하를 분석하였다. 호스와 파이프는 도관에서의 압력강하로, 노즐/리셉터클은 흐름 노즐 식으로, 밸브는 기체 유량 식으로 계산하였다. 또한 각 구성요소에서 발생하는 압력강하 효과를 종합 분석한 결과 전체 충전라인에서 압력강하에 가장 큰 영향을 주는 요소는 밸브에서의 압력강하임이 밝혀졌다. 이번 연구는 추후 수소 충전을 포함한 수소 유동 해석으로 수소 충전 과정의 모델 개발에 활용될 수 있을 것이다.

Applicability of Existing Fracture Initiation Models to Modern Line Pipe Steels

  • Shim, Do Jun
    • 한국압력기기공학회 논문집
    • /
    • 제12권2호
    • /
    • pp.1-24
    • /
    • 2016
  • The original fracture criteria developed by Maxey/Kiefner for axial through-wall and surface-cracked pipes have worked well for many industries for a large variety of relatively low strength and toughness materials. However, newer line pipe steels have some unusual characteristics that differ from these older materials. One example is a test data that has demonstrated that X80 line-pipe with an axial through-wall-crack can fail at pressures about 30 percent lower than predicted with commonly used analysis methods for older steels. Thus, it is essential to review the currently available models and investigate the applicability of these models to newer high-strength line pipe materials. In this paper, the available models for predicting the failure behavior of axial-cracked pipes (through-wall-cracked and external surface-cracked pipes) were reviewed. Furthermore, the applicability of these models to high-strength steel pipes was investigated by analyzing limited full-scale pipe fracture initiation test results. Based on the analyzed results, the shortcomings of the available models were identified. For both through-wall and surface cracks, the major shortcomings were related to the characterization of the material toughness, which generally leads to non-conservative predictions in the J-T analyses. The findings in this paper may be limited to the test data that were consider for this study. The requisite characteristics of a potential model were also identified in the present paper.