• 제목/요약/키워드: Line extraction

검색결과 717건 처리시간 0.03초

Robust Stroke Extraction Method for Handwritten Korean Characters

  • Park, Young-Kyoo;Rhee, Sang-Burm
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -2
    • /
    • pp.819-822
    • /
    • 2000
  • The merit of the stroke extraction algorithm is the ease of the feature abstraction from the skeleton of a character, But, extracting strokes from Korean characters has two major problems that must be dealt with. One is extracting primitive strokes and the other is merging or splitting the strokes using dynamic information of the strokes. In this paper, a method is proposed to extract strokes from an off-line handwritten Korean character. We have developed some stroke segmentation rules based on splitting, merging and directional analysis. Using these techniques, we can extract and trace the strokes in an off-line handwritten Korean character accurately and efficiently.

  • PDF

고압전동기 고정자권선의 부분방전 특징추출 (Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor)

  • 박재준;김희동;이동윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.112-116
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet transform coefficients.

  • PDF

표 서식 문서의 구조 분석을 위한 선분 에지 기반의 유형별 꼭짓점 검출 (Line Edge-Based Type-Specific Corner Points Extraction for the Analysis of Table Form Document Structure)

  • 정재영
    • 디지털콘텐츠학회 논문지
    • /
    • 제15권2호
    • /
    • pp.209-217
    • /
    • 2014
  • 표 서식을 활용하고 있는 수많은 문서들을 종류에 따라 자동으로 분류하거나, 서식에 기입된 정보를 서식과 분리하여 추출하는 기술은 매우 중요하게 활용된다. 이를 위해서는 표 서식 구조를 정확하게 파악하는 과정은 필수적이다. 본 논문에서는 표 서식 문서 영상에 대한 유형별 꼭짓점 검출 방법을 제안한다. 주요 처리 과정은 전처리, 에지 블록 검출, 선분 에지 블록 검출, 꼭짓점 검출 단계를 거친다. 추출된 꼭짓점들은 선분 에지들이 다양한 형태로 직교하는 교차점들로 9가지 유형으로 분류된다. 실험에서는 제안한 방법을 세금계산서, 거래명세표, 표를 포함하고 있는 일반 문서 등과 같은 몇 가지 형태의 영상에 적용하여 99% 이상의 유형별 꼭짓점 추출 성능 결과를 보인다. 서식 문서 내에서의 대부분의 꼭짓점들은 대칭 형태로 존재한다는 사실을 고려할 때, 꼭짓점의 유형, 선분 에지의 폭 및 그들의 위치 관계를 활용하여 서식의 구조 분석에 활용 가능하다.

Automatic Power Line Reconstruction from Multiple Drone Images Based on the Epipolarity

  • Oh, Jae Hong;Lee, Chang No
    • 한국측량학회지
    • /
    • 제36권3호
    • /
    • pp.127-134
    • /
    • 2018
  • Electric transmission towers are facilities to transport electrical power from a plant to an electrical substation. The towers are connected using power lines that are installed with a proper sag by loosening the cable to lower the tension and to secure the sufficient clearance from the ground or nearby objects. The power line sag may extend over the tolerance due to the weather such as strong winds, temperature changes, and a heavy snowfall. Therefore the periodical mapping of the power lines is required but the poor accessibility to the power lines limit the work because most power lines are placed at the mountain area. In addition, the manual mapping of the power lines is also time-consuming either using the terrestrial surveying or the aerial surveying. Therefore we utilized multiple overlapping images acquired from a low-cost drone to automatically reconstruct the power lines in the object space. Two overlapping images are selected for epipolar image resampling, followed by the line extraction for the resampled images and the redundant images. The extracted lines from the epipolar images are matched together and reconstructed for the power lines primitive that are noisy because of the multiple line matches. They are filtered using the extracted line information from the redundant images for final power lines points. The experiment result showed that the proposed method successfully generated parabolic curves of power lines by interpolating the power lines points though the line extraction and reconstruction were not complete in some part due to the lack of the image contrast.

하악 제3대구치가 하악 우각부골절 정복술후 감염에 미치는 영향에 관한 연구 (EFFECT OF THIRD MOLAR ON POSTOPERATIVE INFECTION AFTER REDUCTION OF THE MANDIBULAR ANGLE FRACTURE)

  • 최문기;민승기;이동근;오승환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권3호
    • /
    • pp.217-225
    • /
    • 2001
  • Any fracture passing through the socket of a teeth is compounded intraorally, even if the fracture is not displaced and the tooth is firm in its socket. Before the advent of antibiotic therapy the danger of infection in a compounded fracture posed severe problems in treatment. Infection is reduced by antibiotic therapy but prolonged use of antibiotics is not justified in an attempt to save a tooth which might eventually be sacrificed. There is still controversy in the management of third molar in mandibualr angle fracture, particulary in regard to their retention or removal at the time of fracture treatment. So we surveyed the 159 patients who were treated with open reduction of mandibular angle fracture containing third molar in fracture line, and compared with the postoperative infection rate depending on time intervals between injury and operation, eruption state of third molar, non-extraction or extraction of third molar related to eruption state, non-extraction or extraction of third molar related to condiition of third molar and its surrounding periodontium and were to propose treatment guidline of third molar in mandibular angle fracture The results obtained were as follows : 1. There were no statistical significance between the time from injury to operation and postoperative infection. 2. There were no statistical significance between eruption state of third molar and postoperative infection. 3. In case of retention of the third molar, there were no statistical significance between eruption state of third molar and postoperative infection, but in case of extraction, postoperative infection was high rate in complete impacted cases. 4. There were no statistical significance between non-extraction or extraction of third molar and postoperative infection depending on condition of third molar. There are no difference in infection rate statistically according to the time from injury to operation, eruption state and condition of third molar, but retention of third molar revealed lowered infection rate in completely impacted cases. By terms of the manegement of third molar, we should extract or preserve third molar in the line of the mandibular angle fracture according to possibility of infection.

  • PDF

Vulnerability Assessment of a Large Sized Power System Using Neural Network Considering Various Feature Extraction Methods

  • Haidar, Ahmed M. A;Mohamed, Azah;Hussian, Aini
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.167-176
    • /
    • 2008
  • Vulnerability assessment of power systems is important so as to determine their ability to continue to provide service in case of any unforeseen catastrophic contingency such as power system component failures, communication system failures, human operator error, and natural calamity. An approach towards the development of on-line power system vulnerability assessment is by means of using an artificial neural network(ANN), which is being used successfully in many areas of power systems because of its ability to handle the fusion of multiple sources of data and information. An important consideration when applying ANN in power system vulnerability assessment is the proper selection and dimension reduction of training features. This paper aims to investigate the effect of using various feature extraction methods on the performance of ANN as well as to evaluate and compare the efficiency of the proposed feature extraction method named as neural network weight extraction. For assessing vulnerability of power systems, a vulnerability index based on power system loss is used and considered as the ANN output. To illustrate the effectiveness of ANN considering various feature extraction methods for vulnerability assessment on a large sized power system, it is verified on the IEEE 300-bus test system.

실리콘기판 효과를 고려한 전송선 파라미터 추출 및 신호 천이 (Parameter extraction and signal transient of IC interconnects on silicon substrate)

  • 유한종;어영선
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.871-874
    • /
    • 1998
  • A new transmission line parameter extraction method of iC interconnects on silicon substrate is presented. To extract the acurate parameters, the silicon substrate effects were taken into account. Since the electromagnetic fields under the silicon substrate are propagated with slow wave mode, effective dielectric constant and different ground plane with the multi-layer dielectric structures were employed for inductance and capacitance matrix determination. Then accurate signal transients simulation were performed with HSPICE by using the parameters. It was shown that the simulation resutls has an excellent agreement with TDR/TDT measurements.

  • PDF