• Title/Summary/Keyword: Limiting Efficiency

Search Result 257, Processing Time 0.025 seconds

Evaluation of Bioremediation Effectiveness by Resolving Rate-Limiting Parameters in Diesel-Contaminated Soil

  • Joo, Choon-Sung;Oh, Young-Sook;Chung, Wook-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.4
    • /
    • pp.607-613
    • /
    • 2001
  • The biodegradation rates of diesel oil by a selected diesel-degrading bacterium, Pseudomonas stutzeri strain Y2G1, and microbial consortia composed of combinations of 5 selected diesel-degrading bacterial were determined in liquid and soil systems. The diesel degradation rate by strain Y2G1 linearly increased $(R^2=0.98)$ as the diesel concentration increased up to 12%, and a degradation rate as high as 5.64 g/l/day was obtained. The diesel degradation by strain Y2G1 was significantly affected by several environmental factors, and the optimal conditions for pH, temperature, and moisture content were at pH8, $25^{\circ}C$, and 10%, respectively. In the batch soil microcosm tests, inoculation, especially in the form of a consortium, and the addition of nutrients both significantly enhanced the diesel degradation by a factor of 1.5 and 4, respectively. Aeration of the soil columns effectively accelerated the diesel degradation, and the initial degradation rate was obviously stimulated with the addition of inorganic nutrients. Based on these results, it was concluded that the major rate-limiting factors in the tested diesel-contaminated soil were the presence of inorganic nutrients, oxygen, and diesel-degrading microorganisms. To resolve these limiting parameters, bioremediation strategies were specifically designed for the tested soil, and the successful mitigation of the limiting parameters resulted in an enhancement of the bioremediation efficiency by a factor of 11.

  • PDF

TRADITIONAL PIG FARMING IN THE SOUTH PACIFIC: PROBLEMS AND OPPORTUNITIES FOR INCREASING PRODUCTIVITY

  • Ochetim, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.3
    • /
    • pp.347-360
    • /
    • 1993
  • The project was undertaken to provide information on the present system of traditional pig farming in the South Pacific region, to identify the problems currently limiting productivity of such pigs and to offer practical strategies which could be used for increasing productivity of the animals. The problems were identified by surveying some 220 subsistence pig farms in eleven island countries in the South Pacific region using a prepared questionnaire. The units were found to be generally small, consisting of about 2-4 sows per herd. The productivity of the units as assessed in terms of sow reproductive efficiency was rather low, being only about 7.5. Feed, housing, breeding, disease, marketing, lack of capital, technical know-how and existing social traditions were identified as current constraints. Based on three of the most limiting factors identified namely feed, housing and breeding, strategies for improvement were developed on the basis of better and more effective use of locally available feed resources, better housing and genetic improvement through crossbreeding programmes. These improvement strategies were tested as a package model on some ten farms in two of the island countries. The results of these on-farm trials indicated that using the improvement strategies increased sow reproductive efficiency by approximately 60 percent, to nearly 12. The significance of these findings in the overall management of traditionally raised pigs in the South Pacific region is discussed.

Electrodialysis with a channeled stack for high strength cadmium removal from wastewater

  • Kyung Jin, Min;Hyo Jin, An;Ah Hyun, Lee;Hyun-Gon, Shin;Ki Young, Park
    • Membrane and Water Treatment
    • /
    • v.14 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • In this study, high concentrations of cadmium-containing wastewater were treated by electrodialysis (ED) with a channel stack. The limiting current density (LCD), cadmium removal efficiency, and current efficiency were investigated under each experimental condition according to the Reynolds number (Re), membrane area, and pH. With the increase in the film area to 111, 333, 555, and 777 cm2 at Re (109.1), LCDs decreased to 408.11, 44.45, 35.32, and 13.64 A/m2, respectively. The highest cadmium removal efficiency (99.6%) and current efficiency were obtained for the membrane area of 111 and 777 cm2, respectively. Under changing Re in the pH range of 1 to 4, Re and LCD were proportional under the same pH condition, and pH and LCD tended to be inversely proportional under the same Re condition. Cadmium removal rate was the best at the pH range 3 - 4. It has been found that ED with channeled stacks can be successfully applied to treat wastewater containing high concentrations of cadmium.

AN ACCURATE AND EFFICIENT CALCULATION OF HIGH ENTHALPY FLOWS USING A HIGH ORDER NEW LIMITING PROCESS

  • Noh, Sung-Jun;Lee, Kyung-Rock;Park, Jung-Ho;Kim, Kyu-Hong
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.15 no.1
    • /
    • pp.67-82
    • /
    • 2011
  • Calculation of accurate wall heat flux for high enthalpy flows requires a dense grid system, which leads to significantly large computational time. A high-order scheme can improve the efficiency of calculation because wall heat flux can be obtained accurately even with a relatively coarse grid system. However, conventional high order schemes have some drawbacks such as oscillations near a discontinuity and instability in multi-dimensional problem. To resolve these problems, enhanced Multi-dimensional Limiting Process(e-MLP) was applied as a high-order scheme. It could provide robust and accurate solutions with high order accuracy in calculation of high enthalpy flows within a short time. We could confirm the efficiency of the high order e-MLP scheme through grid convergence tests with different grid densities in a hypersonic blunt nose problem.

Proposal of improvement measures according to the limiting factors of the use of drone technology : Cases in the construction field

  • Yoo, Soonduck
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.30-38
    • /
    • 2021
  • This research explored methods for improvements to be made within the field of drone usage within the construction industry based on an investigation of factors which limit their efficiency and productivity. Limiting factors and improvement measures were presented in terms of technology, service, law and policy for employing drones at construction sites. Our first suggestion is, from a technical point of view, that companies need to expand professional manpower and infrastructure for systematic management. Second, in terms of service expansion, it is necessary to have management capabilities for operation such as the use of drones with enhanced safety and reinforced on-site education and personal information management. Third, in terms of legal and institutional support measures, it is necessary to prepare a plan for reforming the legal system for revitalization and to expand the training of professional manpower. This study may contribute not only to the development of drone technology, but also to effectively respond to various problems that appear at construction sites.

Lagged Unstable Regressor Models and Asymptotic Efficiency of the Ordinary Least Squares Estimator

  • Shin, Dong-Wan;Oh, Man-Suk
    • Journal of the Korean Statistical Society
    • /
    • v.31 no.2
    • /
    • pp.251-259
    • /
    • 2002
  • Lagged regressor models with general stationary errors independent of the regressors are considered. The regressor process is unstable having characteristic roots on the unit circle. If the order of the lag matches the number of roots on the unit circle, the ordinary least squares estimator (OLSE) is asymptotically efficient in that it has the same limiting distribution as the generalized least squares estimator (GLSE) under the same normalization. This result extends the well-known result of Grenander and Rosenblatt (1957) for asymptotic efficiency of the OLSE in deterministic polynomial and/or trigonometric regressor models to a class of models with stochastic regressors.

New electrode structure for reducing power consumption of PDPs

  • Jung, Hae-Yoon;Cheong, Hee-Woon;Lee, Tae-Ho;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.69-72
    • /
    • 2008
  • A new electrode structure is proposed in this paper which can increase the discharge efficiency of plasma display panels and also decrease the panel capacitance by decreasing the electrode area effectively. Even with the decreased electrode area, the proposed structure could suppress the requirement for increasing the voltage and improve efficiency by limiting the discharge current.

  • PDF

Removal of nitrate by electrodialysis: effect of operation parameters

  • Park, Ki Young;Cha, Ho Young;Chantrasakdakul, Phrompol;Lee, Kwanyong;Kweon, Ji Hyang;Bae, Sungjun
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.201-210
    • /
    • 2017
  • We investigated the effect of applied voltage and electrolyte concentration on the nitrate removal and its energy/current efficiency during the electrodialysis. The current increased as the applied voltage increased up to 30 V showing the limiting current density around 20 V. The nitrate removal efficiency (31 to 71% in 240 min) and energy consumption (11 to $77W{\cdot}h/L$) gradually increased as the applied voltage increased from 10 to 30 V. The highest current efficiency was obtained at 20 V. The increase in electrolyte concentration from 100 to 500 mM led to the dramatic increase of nitrate removal efficiency with much faster removal kinetics (100 % in 10 min).

Anodic Oxidation of Potassium Iodide Solution (Ⅰ) (요오드화칼륨 수용액의 양극산화 (제1보))

  • Nam, Chong-Woo;Kim, Hark-Joon
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.5
    • /
    • pp.378-384
    • /
    • 1973
  • To investigate the mechanism of the reaction of electrolytic oxidation of iodide to iodate ions, polarization curves are determined in various kinds of solution using electrodeposited lead peroxide and platinum anodes. It was observed from the polarization curves that the limiting current is exists at concentration 1.5 M of potassium iodide, and these limiting current disappeared as potassium hydroxide was added up to concentration of 0.1 M. while in case of platinum anode, limiting current did not appear in dilute potassium iodide solution. These results are owing to the chemical reaction, $PbO_2+2I^{-}+2H^+{\to}PbO+I_2+H_{2}O$ ocurring at the surface of lead peroxide anode. Also, we studied to obtain the optimum conditions of electrolytic preparation of iodate from iodide solution using a cell without the diaphragm. The results are that; (a) addition of potassium dichromate at the anti-reducing agent is proper in concentration of 0.1 g/l, (b) electrolytic temperature is not so much effective in raising the current efficiency, (c) current efficiency is increased with current density, and (d) electrolysis is the most effective in weak alkaline solutions.

  • PDF

A High Efficiency Electrolytic Cell by Superposing Pulsed Corona Discharge in Water (수중 펄스코로나 방전을 중첩한 고효율 강전해수 발생장치)

  • 이재용;김진규;정성진;박승록;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.79-85
    • /
    • 2001
  • A conventional electrolyzing cell has been made by an ion exchange membrane inbetween parallel plate electrodes. A low dc voltage is applied to the electrodes for electrolyzing and the efficiency is remained in low. in this study, a novel electrolyzing cell with a pair of slit-type third electrodes installed inbetween parallel plate electrodes has been proposed and investigated experimentally. And pulse power wa supplied to between each electrodes. This slit type of third electrodes can concentrate the strong electric fields at the every its edges to accelerate the electrolyzing powers, and to generate oxygen bubble discharges for generating oxidants. And moreover the slits eliminate the space charge limiting action and the temperature of the water by leaking out through the slits from electrolyzing region to outside of the main electrode region. As a result, it was found that a strong electorzed water of pH 2.8 and pH 10.5 and oxidants dissolved water of 1 [ppm] in acidic water were obtained with a tap water fed at the electric current of 2 [A], which however were several times higher oxidant and ion concentration quantity compared with the conventional cell.

  • PDF