• Title/Summary/Keyword: Limit Distance

Search Result 480, Processing Time 0.031 seconds

Design Anamorphic Lens Thermal Optical System that Focal Length Ratio is 3:1 (초점거리 비가 3:1인 아나모픽 렌즈 열상 광학계 설계)

  • Kim, Se-Jin;Ko, Jung-Hui;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.409-415
    • /
    • 2011
  • Purpose: To design applied anamorphic lens that focal length ratio is 3:1 optical system to improve detecting distance. Methods: We defined a boundary condition as $50^{\circ}{\sim}60^{\circ}$ for viewing angle, horizontal direction 36mm, vertical direction 12 mm for focal length, f-number 4, $15{\mu}m{\times}15{\mu}m$ for pixel size and limit resolution 25% in 33l p/mm. Si, ZnS and ZnSe as a materials were used and 4.8 ${\mu}m$, 4.2 ${\mu}m$, 3.7 ${\mu}m$ as a wavelength were set. optical performance with detection distance, narcissus and athermalization in designed camera were analyzed. Results: F-number 4, y direction 12 mm and x direction 36 mm for focal length of the thermal optical system were satisfied. Total length of the system was 76 mm so that an overall volume of the system was reduced. Astigmatism and spherical aberration was within ${\pm}$0.10 which was less than 2 pixel size. Distortion was within 10% so there was no matter to use as a thermal optical camera. MTF performance for the system was over 25% from 33l p/mm to full field so it was satisfied with the boundary condition. Designed optical system was able to detect up to 2.9 km and reduce a diffused image by decreasing a narcissus value from all surfaces except the 4th surface. From sensitivity analysis, MTF resolution was increased on changing temperature with the 5th lens which was assumed as compensation. Conclusions: Designed optical system which used anamorphic lens was satisfied with boundary condition. an increasing resolution with temperature, longer detecting distance and decreasing of narcissus were verified.

Accuracy Evaluation of Reflective Sheet Target Total Station for Applying in Cadastral Resurvey (지적재조사 측량에 적용을 위한 반사시트 타깃 토털스테이션 측량의 정확도 평가)

  • Park, Ki Heon;Hong, Sung Eon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.91-97
    • /
    • 2014
  • In this research, we would try to evaluate the applicability in cadastral resurvey surveying by analysing the accuracy of building boundary surveying using the reflective sheet total station surveying. When we analyse it, we refer the reflective sheet which can supplement not only the difficulties of total station surveying and GPS surveying caused by the diversity of the building structure but also the errors of non prism total station caused by material of the object. Each reflected angles $90^{\circ}$ and $60^{\circ}$, $30^{\circ}$ of RMSE results were analyzed by RMSE between 1.2mm~2.8mm and 2.2mm~4.0mm, 2.5mm~4.4mm for each distance. The result of X RMSE was analyzed to be 0.0043m in a boundary surveying for existing building between prism surveying and reflective sheet surveying, and also Y RMSE was 0.038m. The source of error is estimated that the body of the prism can not be exactly attached to the edge of a building. Therefore, it will be very helpful to use a reflective sheet surveying with a prism in both the limit of collimation and error reductions as a building boundary measurement in cadastral resurvey surveying.

Assessment of Equivalent Heights of Soil for the Lateral Earth Pressure Against Retaining Walls Due to Design Truck Load by 3D Numerical Analysis (3차원 수치해석에 의한 표준트럭하중에 의해 옹벽에 작용하는 수평토압의 등가높이 산정)

  • Seo, Seunghwan;Jin, Hyunsik;Kim, Dongwook;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.75-85
    • /
    • 2019
  • The lateral load from traffic depends on standard truck's axle loads and locations, loading distance from the inner wall. The method of limit state design has been adopted and used for design of roads in the Republic of Korea since 2015. The concept of equivalent height of soil accounting for traffic loading is often used for design of retaining walls to quantify the traffic loads transmitted to the inner wall faces. Due to the different characteristics of the standard design trucks between Korea and US (AASHTO), the direct use of the guidelines from AASHTO LRFD leads to incorrect estimation of traffic load effects on retaining walls. This paper presents the results of evaluation of equivalent height of soil to reflect the standard truck of the nation, based on the findings from analytical solutions using 3D finite element method. Compare to US, the standard truck loading has a structure where the axle load is concentrated so that the equivalent load height is estimated to be slightly larger than AASHTO for lower retaining wall height. It would be reasonable to present the equivalent load height in Korea more conservatively than AASHTO in terms of securing long term stability of the retaining wall structure.

A numerical study of the effects of the ventilation velocity on the thermal characteristics in underground utility tunnel (지하공동구 터널내 풍속 변화에 따른 열특성에 관한 수치 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Ra, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.29-39
    • /
    • 2017
  • In this research, thermal design data such as heat transfer coefficient on the wall surface required for ventilation system design which is to prevent the temperature rise in the underground utility tunnel that three sides are adjoined with the ground was investigated in numerical analalysis. The numerical model has been devised including the tunnel lining of the underground utility tunnel in order to take account for the heat transfer in the tunnel walls. The air temperature in the tunnel, wall temperature, and the heating value through the wall based on heating value(117~468 kW/km) of the power cable installed in the tunnel and the wind speed in the tunnel(0.5~4.0 m/s) were calculated by CFD simulation. In addition, the wall heat transfer coefficient was computed from the results analysis, and the limit distance used to keep the air temperature in the tunnel stable was examined through the research. The convective heat transfer coefficient at the wall surface shows unstable pattern at the inlet area. However, it converges to a constant value beyond approximately 100 meter. The tunnel wall heat transfer coefficient is $3.1{\sim}9.16W/m^2^{\circ}C$ depending on the wind speed, and following is the dimensionless number:$Nu=1.081Re^{0.4927}({\mu}/{\mu}_w)^{0.14}$. This study has suggested the prediction model of temperature in the tunnel based on the thermal resistance analysis technique, and it is appraised that deviation can be used in the range of 3% estimation.

Parcel Boundary Demarcation in Residential Area Using High Resolution Aerial Images (고해상도 항공영상을 이용한 주거지역 필지경계 설정에 관한 연구)

  • Park, Chiyoung;Lee, Jaeone
    • Spatial Information Research
    • /
    • v.23 no.1
    • /
    • pp.59-68
    • /
    • 2015
  • As part of an effort to leap smart cadastre system by doing rearrangement of various mismatches in the land register, the cadastre renovation project is being recently conducted. In response to this demand, this paper proposes an image-based rapid parcel boundary demarcation plan using the high resolution aerial image with a GSD (Ground Sample Distance) of 5cm that matches to real ground boundary situation in residential area. To review the feasibility and accuracy of this proposed methodology, we compared the accuracy of parcel boundary point and parcel area extracted from the digital stereo plotting on the basis of results of cadastral boundary surveying and land register over the selected two test areas. The comparative accuracy result of all boundary points by digital stereo plotting is satisfied with accuracy requirement according to the criteria of the enforcement regulation of cadastral surveying, whereas it exceeded allowable error of ${\pm}0.07m$, more strictly specified in the Special Act on Cadastral Renovation. And about 20% of the total 70 parcels extracted by digital plotting are out of area tolerance in Jecheon study area, and 10% of the total 19 parcels in Suwon study area. The parcels exceeding accuracy limit are mostly due to the occlusion caused by building roof or eaves, and the obstacles such as trees existing on the boundary. Furthermore, an object identification is impossible in image because of vague boundary reference in case of nonexistence of man-made structures or natural features. Therefore, the utilization of boundary identification stickers is recommended as a solution for these types of land parcel.

Relationship between mesiodistal width and enamel thickness in mandibular incisors (하악 절치 근원심폭경과 법랑질 두께의 관계)

  • Han, Uk;Gang, Sung-Nam;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.41 no.3
    • /
    • pp.184-190
    • /
    • 2011
  • Objective: The purpose of this study was to investigate the relationship between the enamel thickness of proximal surfaces and the morphologic features of mandibular incisors. Methods: Mesiodistal/faciolingual (MD/FL) index, MD width, and height of contour width/cervical width ratio were measured in 40 incisors extracted from Koreans. For determining the height of contour width/cervical width ratio, the cervical width was measured as the distance between proximal cementoenamel junctions. Then, the labial surface was ground to the height of the contour level to measure enamel thickness. Pearson correlation analysis was used to investigate the correlation between enamel thickness and morphologic features. Results: Enamel thickness was $0.75{\pm}0.07mm$ per side, and MD width was $5.56{\pm}0.40mm$. Enamel thickness and MD width were significantly correlated. However, a significant relationship was not observed between enamel thickness and MD/FL index or the height of contour width/cervical width ratio. Conclusions: The results suggest that enamel thickness is affected only by MD width. Therefore, if the MD width is the same for mandibular incisors with a large MD/FL index or triangular shape and mandibular incisors with normal shape, then the limit of enamel reduction for reproximation will be the same.

Radiated Emission of Electrical Fast Transient/Burst Signal and Its Countermeasures (전기적으로 빠른 과도현상/버스트 신호의 복사방출과 대책)

  • Park, Soo Hoon;Kim, Dong Il;Park, Youn Joon;Nah, Seung Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.291-298
    • /
    • 2016
  • In this paper, we studied about the radiated emission of EFT(Electrical Fast Transient)/Burst signal, referenced IEC-61000-4-4 of the international EMC standard and its effect on EUT(Equipment Under the Test) when EFT/Burst signal (Conducted noise) induced on a power cable to EUT. Firstly, we set up test sample by the standard and +4 kV standard signal is induced by EFT/Burst signal generator with 1 m length power cable for 1 minute. Consequently, we found not only induced EFT/Burst signal along power line, but also directly radiated emission signal from EFT/Burst signal generator (Radiated emission noise of EFT/Burst). The radiated emission signal of EFT/Burst was 30 dB which is higher than limit of CISPR 22 which is international EMC standard. Moreover, we measured the electric field strength by changing distance from maximum radiated emission point to electric field strength tester. As a result, this electric field strength was 23 V/m which is higher than international EMC standard test level(CISPR 24). Therefore, it was confirmed that the probability of malfunction may be high when radiated emission of EFT/Burst noise exists near the EUT.

Outpatient Radioablation Therapy for Thyroid Cancer Patients with Minimal Radiation Exposure to the Family Members (갑상선암 환자의 방사선옥소 외래치료시 가족 구성원의 방사선량 측정)

  • Park, Hee-Myung;Jang, Jung-Woong;Yang, Hee-Chul;Kim, Young-Gook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.218-225
    • /
    • 2007
  • Purpose: Postoperative thyroid remnant radioablation therapy is necessary to reduce the recurrence and mortality rates as well as to prepare the patients for a proper long term surveillance of well-differentiated thyroid cancers. The radiation safety rules of the government require the patient to be isolated in a hospital if the expected radiation exposure to the family members would be greater than 5 mSv (500 mRem). The purpose was to measure the radiation received by the family members of patients who received large doses of NaI-131. Material and Methods: We have administered 12 therapy doses ranging from 3.70-5.55 GBq (100 to 150 mCi) to 11 patients, and released them immediately if they met the radiation safety criteria. Informed consent was obtained from the subjects prior to the therapy, and each of them agreed to follow written radiation safety instructions. TLD badges were used to measure the radiation dose received by the family members and the room adjacent to the patient's bed room during the first 72 hours. Results: The average dose received by the family members who spent the most time in the closest distance with the patients was 0.04 mSv with a range of 0.01-0.17 mSv. Even the highest dose was only about 3% of the limit set by the government. The average radiation dose to the outer wall of the patient's room was 0.15 mSv. Conclusion: It is concluded that I-131 ablation therapy can be administered to outpatients safely to thyroid cancer patients who meet the established radiation safety criteria and follow the instructions.

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

A Study on Intensive Quantities Handled in Korean Elementary Math Textbooks and Workbooks (우리나라 초등학교 수학 교과서 및 익힘책에서 취급하는 내포량에 관한 연구)

  • Choi, Jong Hyeon;Ko, Jun Seok;Lee, Jeong Eun;Park, Kyo Sik
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.20 no.1
    • /
    • pp.1-15
    • /
    • 2016
  • In this paper, the following three issues are discussed in connection with intensive quantities. (1) Is there any relationship among intensive quantity, per unit quantity, and ratio? (2) Which intensive quantities obtained by two same extensive quantities are handled? And How are they handled? (3) Which intensive quantities obtained by two different extensive quantities are handled? And How are they handled? Based on the results of this discussions, three implications are suggested as conclusions to explore the direction for the development of handling intensive quantities in elementary math textbooks and workbooks. Firstly, it is necessary to systematize the systemize a series of processes to handle intensive quantities. There is a need to rethink to use terms like speed and velocity before handling the ratio. Secondly, there is a need to rethink the definition of intensive quantities which have the particular names. For example, it is necessary to rethink using average distance in the definition of speed and the average population in the definition of density of population. Thirdly, it is necessary to consider the limiting the kinds of intensive quantities obtained by two same extensive quantities handled in the elementary math. There is a need to set limit to them which are used in daily life, and there is a need to rethink to use them which are used in the specialized area. There is a need to rethink the using hitting ratio in the form of %.