• 제목/요약/키워드: Lighting conditions

검색결과 510건 처리시간 0.027초

Empirical Evaluation of Optimal User-Centered LED Lighting Environments in Residential Bathrooms

  • Lee, Jeongmin;Choi, Kyungah;Suk, Hyeon-Jeong
    • 감성과학
    • /
    • 제16권3호
    • /
    • pp.305-310
    • /
    • 2013
  • This user-centered research aims to empirically evaluate color temperature (K) and illuminance (lx) of residential bathroom lightings to determine the most optimal lighting conditions for productive task performance as well as for satisfying users' emotional needs. Using 3 LED lighting fixtures, 4 types of lighting contexts were investigated; main lighting, task lighting, shower lighting, and bath lighting. Two lightings were installed parallel to the vertical edges of the main bathroom mirror to be used as main and task lighting, while another fixture was installed above the bathtub to be used for shower and bathing. For each lighting context, subjects (N=54) were instructed to perform a few tasks during which time the users were exposed to different lighting conditions with color temperature ranging from 2700 K ~ 6500 K and illuminance ranging from 100 lx ~ 700 lx. Upon completing the given tasks, subjects were asked to evaluate the lighting conditions and their applicability for performing the given tasks. Based on the user evaluations, the most optimal lighting conditions for the different lighting scenarios are as follow: 1) 3500 K ~ 4300 K and 150 lx for main lighting, 2) 3500 K ~ 4300 K and 500 lx ~ 700 lx for task lighting, and 3) 2700 K ~ 3500 K and 100 lx ~ 150 lx for shower/bath lighting. These results can be used to adjust the lighting standards suggested by KS, as well as be utilized by both engineers and designers in designing new types of user-centered bathroom lightings.

  • PDF

휴게실 공간의 조명환경에 대한 시각적 감지 및 심리적 반응에 따른 공간 인지도 변화 (Variation of Spatial Cognition According to Visual Perception and Psychological Responses for Lighting Environments in Rest Space)

  • 김재상;이지현;김수영
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.443-453
    • /
    • 2012
  • This study examines visual perception and spatial satisfaction according to lighting conditions. Field measurements and surveys were performed in three rest space of university buildings where various lighting conditions were employed. Results indicate that overall impression of space improved when low color temperature, such as 3,000 K governed overall lighting environment and accent lighting was used for wall surfaces. Lighting conditions that kept uniform illuminance levels using area light sources containing fluorescent lamps with 6,500 K failed to keep favorable spatial satisfaction for space. High color temperature was not recommended for lighting in rest space. Asymmetrical illuminance levels formed by low color temperature such as 3000 K is recommended to keep positive mood and improve spatial satisfaction in rest space. Overall impression of the space was influenced by visual comfort, color temperature, spatial satisfaction and brightness. Spatial satisfaction for space was effectively impacted by psychological comfort, color temperature and overall impression for lighting conditions. Psychological comfort in space was influenced by color temperature, spatial satisfaction and visual annoyance from reflected light.

작업환경에서 의자 및 조명 조건이 근로에 미치는 영향에 관한 연구 (A Study on the Effect of Seating & Lighting conditions on Work)

  • 차상은;김상렬;이승주;김정동;김종석
    • 한국안전학회지
    • /
    • 제13권1호
    • /
    • pp.131-138
    • /
    • 1998
  • This field study was conducted to survey the effect of seating & lighting conditions on work. The results were as follows ; Discomfortable parts of body caused by unsuitable sitting postures on work were low back 52.05%, leg 15.75%, neck 14.38% and arm 9.59%. Work conditions of sitting postures were needed arm rest, back rest of seat and adjustable seat height. Effect of work efficiency by lighting conditions were statistically significant relationship between glaring state of workstation and lighting state.

  • PDF

아파트 거실과 주방의 조명환경에 관한 연구 (A Study on the Lighting Environment of Living Room and Kitchen in Apartment Houses)

  • 임만택;권창룡;김현태
    • 한국주거학회논문집
    • /
    • 제18권1호
    • /
    • pp.35-42
    • /
    • 2007
  • This study aims at examining the actual conditions of lighting environment and the consciousness and responses of residents with the living room of apartment house, grasping the problems of existing lighting methods, offering the lighting environment design standard in harmony with the various demands of residents, functions of living room space, life in living room and interior decoration and then pursuing the comfortable living environment. As the scope and methods of research for these, existing research methods are examined through the consideration of preceding researches and the basic outline of this research is constructed. Questionnaire survey is conducted with six apartment complexes including Kumho district, Munhung district, Sangmu district, Unnam district, Ilkok district and Chumdan district, the problems and improvements of lighting environment conditions are examined, conception and selection of lighting equipment design image are made, lighting equipment design of living room is suggested and the expected effects of lighting equipment ordering method are arranged as follows. As a result of examining and analyzing the lighting environment of living room in existing apartment houses, it is known that the conditions of existing lighting environment considered uniform lighting plan for functional sides of each room which didn't consider the various living behaviors and preference of residents and while the degree of interior decoration design is actually positive. Accordingly it seems that the lighting equipment ordering which considers the various preferences of residents is applied as the means for comfortable lighting environment, the interior environmental mood will be greatly improved.

소규모 사무실공간에서 주광조건에 따른 대비효과 및 조명에너지 절약예측 (Prediction of Contrast and Lighting Energy Saivings in a Small Office Space according to Daylight Conditions)

  • 김수영
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.35-43
    • /
    • 2004
  • Illuminance and luminous levels in a small office space due to daylight were calculated to analyze the impact of daylight on contrast and lighting energy savings. Computer simulations were performed for four blind conditions under a clear sky condition. The blind conditions significantly impacted the illuminance an4 luminance level. Visual performance scores were calculated according to the transfer function that uses absolute contrast between target and background surface. The blind condition that had 45 tilted angle toward ground provided good contrast and performance scores. Using a control algorithm of an automated daylight dimming control system lighting energy sayings were predicted. For all blind conditions minimum lighting energy was consumed.

ACHIEVING CONSISTENCY IN LIGHTING SCHEMES FOR CONSTRUCTION WORK ZONES THROUGH LIGHTING SIMULATION

  • Khaled Nassar;Soo-Young Kim
    • 국제학술발표논문집
    • /
    • The 2th International Conference on Construction Engineering and Project Management
    • /
    • pp.269-278
    • /
    • 2007
  • Nighttime construction is being adopted by many state DOT's as a way to mitigate the impact of construction operations on the traveling public. Although a number of states have developed standard specifications for nighttime lighting, these standards are usually in the form of generic requirement statements that only specify minimum illuminance levels. The lighting standards do not include specific ways to achieve this illuminance level such as lighting arrangements and configurations for various work zone plans and construction operations. This leaves confusion between the traffic engineers and the contractors and does not guarantee consistency in those plans, thus affecting productivity and safety (lighting conditions account for 18% to 28% of work zone accidents). The main objective of this study is to utilize three dimensional animation and lighting analysis software to study and model lighting conditions of a construction site. This is expected to increase the safety and productivity of construction operations by achieving consistency in work zone lighting schemes. A computerized model was developed, called Nitelite. Various lighting schemes can be studied using the software to provide for typical applications including lighting fixture's locations, luminance, mounting height, tilt angle, and fixture type. The results from the developed software tool were validated through comparisons with previous research conducted using field measurements.

  • PDF

백화점 의류매장 조명환경에 관한 판매자 의식 및 실태 (Actual Conditions and Awareness of Employees about the Illumination Environment of Apparel Shops in Department Store)

  • 김현지;안옥희
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.13-18
    • /
    • 2004
  • This study investigates actual conditions and awareness of employees female apparel shops within department store in seoul area. Investigating the actual conditions of the lighting indicated that the employees thought that the lighting charged much expenses to them, and the effort to improve the efficiency of current lighting was insufficient for lack of en expert knowledge on the lighting. The average space size of apparel shops were 11.7평, the light source was most frequently used fluorescent lamp and halogen lamp. The illuminance was the most highest nearby wall display(average 1089lx), and nearby hanger(average 1075lx).

  • PDF

대구·경북 지역 거실 조명 실태조사 (A Study on the Actual Conditions of Living Room Lighting in Daegu and Gyeongbuk Districts)

  • 조영미;안옥희;김현진
    • 한국주거학회논문집
    • /
    • 제23권3호
    • /
    • pp.13-20
    • /
    • 2012
  • This research study was conducted to determine the actual conditions of living room lighting in Daegu and Gyeongbuk districts. For this study, 112 households were surveyed. The results of this study are as follows: Firstly, fluorescent light was used as the general illumination of living rooms, and the ratio of not using local sources of illumination was high. Secondly, the standard illuminance was found to be 221. The illuminance was the value that satisfied the activities for togetherness and entertainment, but did not reach the illuminance necessary for other activities, such as reading, make-up, and sewing. In addition, the uniformity of brightness used as a measure of uniformity in examining the results was normal. Thirdly, both the brightness and the satisfaction of lighting in the living room space were indicated to be normal. In addition, in regard to housing lighting, 'stability', and 'brightness of lighting' were indicated as important considerations and 'brightness of lighting', 'shadow' and 'management of lighting' were indicated as problem areas.

LED 조명 색도에 따른 시간 인지에 대한 연구 (The Influence of Chromacity of LED Lighting on Time Perception)

  • 석현정;김곡미
    • 감성과학
    • /
    • 제13권1호
    • /
    • pp.69-78
    • /
    • 2010
  • 최근 LED는 친환경적인 에너지 소비와 자유로운 조명 연출의 가능성으로 각광을 받고 있는 가운데, LED조명을 활용한 인간의 감성적 반응을 유도하는 감성조명에 대한 관심이 증가하고 있다. 본 연구에서는 실내에 설치된 LED조명의 색도를 변화해가면서 실내 생활인들이 시간을 인지하는데 영향을 받는 것을 두 개의 실험연구를 통하여 밝히고 있다. 실험 1(N=28)에서는 3초~20초에 이르는 짧은 시간을 인지하는데 LED 색도의 변화에 따른 영향이 있는가를 살펴보았다. 실험 결과, 난색 계열의 색채조명환경에서는 백색광 환경에 비하여 시간이 더 천천히 지난 것으로 인지한 반면 한색 계열의 색채조명환경에서는 백색광 환경에 비하여 시간이 더 빨리 지난 것으로 인지하는 경향을 발견하였다. 이러한 현상은 주어진 시간의 길이가 길어질수록 더 분명하게 나타났다. 동일한 실험환경에서 진행된 실험 2(N=39)에서는 실험참여자가 6가지 색채조명환경에서 별도의 인지 과제를 수행하는 동시에 90초의 시간을 가늠하였다. 실험참여자가 인지한 90초의 소요 시간과 실제 소요된 시간과의 차이에서, 색채조명환경이 영향을 미치는 현상을 밝혀내었는데, 실험 1에서와 마찬가지로 난색 계열보다 한색 계열의 색채조명환경에서 시간이 더 빠르게 지난 것으로 인지하는 경향을 관찰할 수 있었으나 통계적으로는 유의하지 않았다. 그리고 선호색 계열의 색채조명환경에서는 시간이 더 빨리 가는 것처럼 인지하는 경향을 발견할 수 있었다.

  • PDF

Regulating Natural Lighting and Ventilation of Residential Buildings in Hong Kong Policy Implications for High-rise, High-density Housing Environments in South Korea

  • Seo, Bokyong;Kim, Sung-Hwa;Lee, Jae-Hoon
    • Architectural research
    • /
    • 제16권3호
    • /
    • pp.81-92
    • /
    • 2014
  • This study discusses the features of the lighting and ventilation regulations for residential buildings in Hong Kong. Given the compact built environment and public concerns about the environmental quality of housing, various lighting and ventilation regulations have been enacted in Hong Kong. The application of building regulations on the micro scale and incentive systems on the macro scale are present, and the governments' calls for more active participation of the private sector and use of the building environmental assessment tools were also noted. Unlike South Korea, however, Hong Kong was found to adopt more performance-based standards, consider the external factors of the lighting and ventilation conditions together with the indoor elements, and provide specific design guidelines. Notwithstanding the different climatic conditions and socio-political contexts of Hong Kong and South Korea, these findings provide some policy implications for the South Korean government in its efforts to achieve a healthy environment for high-rise, high-density housing. It is suggested that the South Korean government adopt more on-site measurement methods to reflect the environmental conditions accurately and broaden the scope and scale of the implementation of the lighting and ventilation regulations with more specific, practical planning and design guidelines.