• 제목/요약/키워드: Lighting Distribution

검색결과 273건 처리시간 0.031초

Image-Based Relighting - Luminance Mapping Based on Lighting Functions

  • Manabe, Tomohisa;Raytchev, Bisser;Tamaki, Toru;Kaneda, Kazufumi
    • International Journal of CAD/CAM
    • /
    • 제12권1호
    • /
    • pp.38-47
    • /
    • 2012
  • The paper proposes a method for generating a sequence of images with smooth transition of illumination from two input images with different lighting conditions. Our relighting approach is image-based, such as the light field rendering. We store the luminances (pixel RGB values) into "lighting functions" consisting of a couple of parameters related to normal vectors. Images with different light positions are rendered by interpolating the luminances retrieved from the lighting functions. The proposed method is a promising technique for many applications requiring a scene with variety of lighting effects, such as movies, TV games, and so on.

Ergonomics Planning에 의한 조명경향 분석 (A Tendency of the Lighting System by Ergonomics Planning)

  • 김희준;박동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2423-2425
    • /
    • 1999
  • During the last years demands for higher visual comfort, flexibility of the lighting system in new type of office structures, especially intelligent building, and compatibility with work at VDU place increased. At the same time better lighting conditions should be realized by energy-effective system leading to less consumption of energy. In the intelligent building need the now type of lighting control system, also it should be included for a human-sensibility. It is shown that when designing lighting for intelligent building, greater importances should be attached to the creation of a well-balanced luminance distribution in the field and research for the people by the Ergonomics Planning.

  • PDF

HDR이미지를 이용한 공동주택 외부조명의 휘도 분석 (Luminance Analysis of the Apartment Exterior Lighting using HDR Images)

  • 홍승대;신은주
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권2호
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

PLS(Plasma Light System)의 내열방사 특성 연구 (Study on the heat-resistance characteristic for PLS(Plasma Light System))

  • 신상욱;이세현;조미령;임종민;황명근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.293-295
    • /
    • 2004
  • PLS(Plasma Light System) is one of the electrodeless lamp discharged by micro wave. In this new lamp has high efficacy and CRI(Color Rendering Index). It is mainly composed of microwave part and optical part. Microwave parts consist of magnetron, wave-guide and cavity-mesh, while optical parts consist of bulb, mirror and reflector. In this paper, we studied experimentally the heat-resistance and temperature distribution characteristics of bulb in PLS.

  • PDF

Measurement System of Photosynthetic Photon Flux Distribution and Illumination Efficiency of LED Lamps for Plant Growth

  • Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • 제37권5호
    • /
    • pp.314-318
    • /
    • 2012
  • Purpose: This study was conducted to develop a measurement system for determining photosynthetic photon flux (PPF) distribution and illumination efficiency of LED lamps. Methods: The system was composed of a linear moving sensor part (LMSP), a rotating part to turn the LMSP, a body assembly to support the rotating part, and a motor controller. The average PPF of the LED lamp with natural cooling and water cooling was evaluated using the measurement system. Results: The PPF of LED lamp with water cooling was 3.1-31.7% greater than that with natural cooling. Based on the measured value, PPF on the horizontal surface was predicted. Illumination efficiency of the LED lamp was slightly increased with water cooling by 3.4%, compared with natural cooling. A simulation program using MATLAB was developed to analyze the effects of the vertical distance from lighting sources to growing bed, lamp spacing, and number of LED lamps, on the PPF distribution on the horizontal surface. The uniformity of the PPF distribution of the LED lamps was fairly improved with 15 cm spacing, as compared to the 5 cm spacing. By simulation, PPF of $217.0{\pm}27.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was obtained at the vertical distance of 40 cm from six LED lamps with 12 cm spacing. This simulated PPF was compared to the measured one of $225.9{\pm}25.6{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. After continuous lighting of 346 days, the relative PPF of LED lamps with water cooling and natural cooling was decreased by 6.6% and 22.8%, respectively. Conclusions: From these results, it was concluded that the measurement system developed in this study was useful for determining PPF and illumination efficiency of artificial lighting sources including LED lamp.

태양광 채광시스템의 조명 적용에 관한 연구 (A Study of a Sunlight Collector System and Its Application)

  • 박준석;어익수;여인선
    • 조명전기설비학회논문지
    • /
    • 제15권4호
    • /
    • pp.1-6
    • /
    • 2001
  • 본 논문에서는 태양광 채광시스템의 출력광의 스펙트럼을 분석하였으며, 그 결과 태양광이 갖는 자외선 분포 보다 낮음을 알 수 있었다. 또한, 출력단의 조명환경을 조명설계 프로그램을 이용하여 6$\times$6$\times$2.3[m]인 최소작업 공간의 조명 환경을 예측하였으며, 광파이버 조명시스템의 출력단의 높이를 1.3[m]에 위치하였을 경우 50$\times$50[cm]의 면적에서 500[lx] 이상의 조도값을 얻을 수 있었다. 이와 같이, 시스템의 가격문제를 개선한다면 실내 조명광 원으로서 가능하리라 본다.

  • PDF

낮은 도로 조명을 위한 Reflector 설계 방법 연구 (A Study of Reflector Design Method for Low Road Illumination)

  • 이정수;박혜진;서진희;정유진;김서영;라현운;정미숙
    • 한국광학회지
    • /
    • 제28권6호
    • /
    • pp.273-280
    • /
    • 2017
  • 본 논문에서는 낮은 도로 조명을 위한 freeform reflector를 설계하였다. 높이에 비해 넓은 차선까지 배광을 보내야 하는 낮은 도로 조명의 경우, 기존의 등주식 도로 조명에 비해 균제도를 맞추기 힘들다는 단점이 있다. 조명 등급 M3를 만족시키기 위해 reflector를 part 9개로 나누어 part 별 반사면의 기울기를 변화시켜 원하는 배광을 갖도록 하였고, 각 점을 기준으로 fitted curve를 그려 이에 따른 수식을 도출하였다. LightTools의 street light simulation을 통해 M3 조명 등급에 만족하는 것을 확인하였고 직접 제작하여 실제 도로상에서 조명 등급을 만족시키며 설계 결과에 대한 타당성을 입증하였다.

광학적 열적 최적화를 통한 6인치 다운라이트 설계 (The Design of 6 inch Down-light by Optimization of the Optical and the Thermal Properties)

  • 김성현;정영기;서범식;양종경;박대희
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1178-1182
    • /
    • 2011
  • The best methods for distribution controled of LED lighting fixtures is control to designed LED chip array, lens and reflector. However, lens design need distribution design to reflector for low-wattage LED lighting because of difficulty of production and reduction of light efficiency. In addition, it needs maximize of thermal performance to improve the efficiency and reliability of device. As a result, for the height of reflector 40[mm] and Inclination 25[$^{\circ}$], we can see the best distribution properties, and, in the thermal properties, junction temperature MCPCB 62.9 [$^{\circ}C$], FR4 PCB 89.6 [$^{\circ}C$], FR4 PCB from Via-hole is 63.1 [$^{\circ}C$]. it may improve for thermal properties for makes the Via-hole.

간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석 (Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires)

  • 김유신;최안섭
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.

LED 열화데이터의 신뢰성 분석 (Reliability Analysis of Degradation Data for LEDs)

  • 박창규
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권1호
    • /
    • pp.59-69
    • /
    • 2009
  • LEDs have rapidly replaced old light devices such as incandescent or fluorescent lamps, and have been widely applied in general lighting, signals, automobile, signs and others. Since LEDs are for both indoor and outdoor use, temperature and humidity inevitably affect its reliability. We explain the result of the degradation life test on LEDs, and guide to reliability analysis procedure. Analysis on reliability measures are performed by Weibull++6 program, and a common shape parameter of Weibull distribution on the LED is suggested. Also, we make a description of reliability analysis procedures for the degradation data using collected test data from degradation tests. Reliability analysis procedures are consisted of estimating degradation models and failure time, verifying of distribution and parameters of the distribution, and estimating of reliability measures. Finally, this paper suggests reliability analysis method for light characteristics on LEDs.

  • PDF