• 제목/요약/키워드: Light - leakage

검색결과 260건 처리시간 0.026초

Optical Compensation in a Vertical Alignment Liquid Crystal Cell for Elimination of the Off-Axis Light Leakage

  • Ji, Seung-Hoon;Choi, Jung-Min;Lee, Gi-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1580-1583
    • /
    • 2008
  • We propose an optical configuration for a vertical alignment (VA) liquid crystal (LC) cell to eliminate the off-axis light leakage in the dark state. The proposed compensation configuration consists of a positive A-film, a positive C-film and a negative C-film. The optical design is performed on a Poincar$\acute{e}$ sphere. This configuration has a better tolerance to the wavelength dispersion, as the polarization trace could self-compensate it. From calculations, we show that the proposed VA LC cell can improve the viewing angle characteristics by compensating for the light leakage in the diagonal direction.

  • PDF

수평배향된 액정셀에서의 스페이서 주변 액정 배향 연구 (Study on the Alignment of the LC near Spacer in a Homogeneously Aligned LC Cell)

  • 정연학;김성운;이종문;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제15권10호
    • /
    • pp.902-908
    • /
    • 2002
  • Homogeneously aligned nematic liquid crystal displays (LCDs) driven by in-plane or fringe field were known to exhibit wide viewing angle and appeared to be black in the off state. However, the existence of spacers inside the cell causes the deformation of the liquid crystal molecules. Such a deformation of the liquid crystal causes light-leakage in the dark state, which lowers contrast ratio of the display. We found that the light-leakage due to deformation of the LC director near the spacer mainly depends on the dielectric anisotropy and the ratio of elastic constants of the LC. In this paper, the mechanism on deformation of the LC near spacer is investigated by optical polarizing microscopy.

Optimization of the Emission Spectrum of Red Color in Quantum Dot-Organic Light Emitting Diodes

  • Jeong, Byoung-Seong
    • 공업화학
    • /
    • 제32권2호
    • /
    • pp.214-218
    • /
    • 2021
  • We investigated the optimal stacked structure from the perspective of process architecture (PA) through emission spectrum analysis according to the wavelength of quantum dot (QD)-organic light-emitting diodes (OLED). We confirmed that the blue-light leakage through the QD can be minimized by increasing the QD filling density above a critical value in the red QD (R-QD) layer. In addition, when the thickness of red-color filter (R-CF) at the upper part of the R-QD increased to more than 3 ㎛, the leakage of blue light through the R-CF was effectively blocked, and a very sharp emission spectrum in the red wavelength band could be obtained. According to these outstanding results, we expect that the development of QD-OLED displays with very excellent color gamut can be possibly realized.

2급와동 광중합 복합레진의 충전방법에 따른 변연누출에 관한 실험적 연구 (A STUDY ON THE MARGINAL LEAKAGE OF CLASS II LIGHT CURING COMPOSITE RESIN RESTORATION ACCORDING TO FILLING METHODS)

  • 김경현;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.55-72
    • /
    • 1993
  • The aim of this study was to compare the marginal leakage of class II light curing composite resin restoration according to filling methods. With using acid etching technique and dentin bonding agent, various methods were suggested to eliminate or reduce the marginal leakage. In this study, class II cavities were prepared in 100 extracted human premolars with cementum margin(1mm below the CEJ) and the teeth were randomly assigned to 5 groups of 20 teeth each. The teeth in group 1, 2, 3 and 4 were restored by direct filling methods using P-50 and Clearfil Photoposterior of 10 teeth each, but the method of insertion of the restorative materials varied with each group. And the teeth in group 5 were restored by inlay method using Kulzer Inlay and CR Inlay. Filling methods are as follows : Group 1 : The composite resin was inserted in one layer in the proximal box and one layer in the occlusal portion. Group 2 : Insertion was in two equally thick horizontal layers in the proximal box. Group 3 : Insertion was in two diagonally placed layers in the proximal box. Group 4 : The composite resin was inserted in the same way as in group 3 except that a glass ionomer liner was first placed on the axial wall and gingival floor. Group 5 : The teeth were restored by Inlay technique using dure cure resin cement. All the teeth were thermocycled, stained with 1 % methylene blue solution, sectioned mesiodistally, and scored for marginal leakage. To compare the marginal leakage, ANOVA and T-test were used in analysis. The following results were obtained : 1. In direct filling methods, there was no significant difference in marginal leakage at both occlusal and cervical margins. 2. In all groups, occlusal margin showed significantly less leakage than cervical margin. 3. In group using glass ionomer liner, there was no significant reduction of marginal leakage at the cervical margin. 4. The group restored by inlay method showed significantly less marginal leakage than groups restored by direct filling methods at both occlusal and gingival margins. 5. There was no significant difference in each group according to filling materials.

  • PDF

Photoelectric Characteristics of a-Si:H Thin Film Transistor by Spectral Properties of Various Backlight Sources

  • Choi, Kyung-Min;Kwon, Sang-Jik;Cho, Eou-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.572-575
    • /
    • 2008
  • Photo leakage characteristics of a-Si:H TFT were obtained for the illuminations from various backlight sources and the results were compared and analyzed in terms of the photoelectric properties of light. The analysis shows that the photocurrents are related to the wavelengths of the peak intensities of the spectrums of light sources.

  • PDF

발수성 회복에 따른 실리콘 고무의 누설전류 특성 (The Properties of Leakage Current of Silicone Rubber wish the Recovery of Hydrophobicity)

  • 서광석;김정호;문중섭;박용관;양계준;유영식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.501-504
    • /
    • 1999
  • The polymer insulators which are installed on outdoor have a great advantage than porcelain and 71ass, due to suppression of leakage current, light weight, low cost, etc. It needs variable evaluation methods for application of these insulators on service. The analysis of measuring leakage current is useful for ageing diagnosis because of monitoring in real-time. In this paper, we look over the recovery of hydrophobicity of silicone rubber in mini salt-fog chamber with leakage current monitoring. also, we understand the relation of between hydrophobicity and leakage current and discuss on method of leakage current monitoring.

  • PDF

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권2호
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

광반응사출성형 시 캐비티 엣지에서 발생하는 미세누출현상에 관한 해석적 연구 (A numerical study on micro leakage behaviors at cavity edge during photo reaction injection molding)

  • 라문우
    • Design & Manufacturing
    • /
    • 제10권3호
    • /
    • pp.8-13
    • /
    • 2016
  • Despite technological advance, there have been several troubles in photo reaction injection molding (photo RIM) to produce ultra thin light guide panels (LGPs). In this study, micro leakage problem at cavity edge during photo RIM was investigated numerically. In order to obtain optimal processing conditions, we regulated inlet pressure of injected resin at the cavity edge and figured out micro leakage behaviors. At low inlet pressure (less than 100 Pa), though the micro leakage problem was not occurred, another problem, short shot due to not enough driving force, was appeared More than 1,000 Pa of the inlet pressure, injected resin was rapidly leaked through the micro gap at the cavity edge. Finally, we obtained optimal inlet pressure around 600 ~ 1,000 Pa. At this region, injected resin fully filled the cavity without micro leakage behavior. Based on the present study, further comparative investigations with experimental photo RIM should be performed to find optimal processing conditions for produce ultra thin LGPs.

가시광선중합화에 따른 충전용 Glass Ionomer Cement의 물리적 성질에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES OF GLASS IONOMER CEMENT FOR RESTORATIVE FILLING USING VISIBLE LIGHT POLYMERIZATION)

  • 신동훈;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.307-330
    • /
    • 1992
  • The aim of this study was to investigate the physical properties of visible light curing Glass Ionomer cement for restorative esthetic filling. The control group was the autopolymerizing GC Fuji II Glass Ionomer cement (2.2: 1 P/L ratio) and the experimental groups were made by following procedure. To induce the polymerization by visible light, the powder of GC Fuji II GI cement and the liquid of Vitrabond for base & liner were mixed in an amalgam capsule with 2.5:1, 3.0:1, 3.5:1 P/L ratio (% wt/wt). After fabrication of specimens, compressive strength, fracture toughness ($K_{IC}$) Scanning Electron Microscope and X-ray Diffraction, water-leachable content, marginal leakage and surface roughness were studied. The results were as follows: 1. Only experimental No. 1 group (visible light curing) showed less compressive strength than control group 1 hour after curing. Strength was increased with aging in all groups, so the compressive strength of light curing groups was no less than that of autopolymerizing group after 3 weeks. 2. Experimental No.3 group (visible light curing) was inferior to No.2 group (visible light curing) in fracture resistance but light curing groups were more resistant to fracture than autopolymerizing group and showed ductile fracture pattern as compared with the brittle fracture pattern of autopolymerizing group. 3. From scanning electron microscopic image, various sized unreacted powder particles, surrounded by silica gel, were embedded in polysalt matrix. Light curing groups showed little crack and more dense unreacted particles than autopolymerizing group. 4. From X-ray diffraction analysis, GC Fuji II Glass Ionomer cement powder and all groups showed glassy appearance but light curing groups seemed to be more intensive in crystaline than autopolymerizing group. S. The most significant dissolution was shown in early setting period in all group. Light curing groups were dissolved less than autopolymerizing group. 6. Marginal leakage was not different significantly in case of cavity margin composed of same tooth structure (ex. only enamel margin, only dentin margin) but much more leakage was shown in dentin/cementum margin than enamel margin. In only case of only enamel margin, light curing groups were superior to autopolymerizing group. 7. All groups showed relatively smooth surface, which irregularity was less than $1{\mu}m$. Light curing groups were smoother than autopolymerizing group.

  • PDF

단조프레스기의 유압유 누유영역 영상 감지 시스템 (Image Detection System for Leakage Regions of Hydraulic Fluid in Faring Press Machine)

  • 배성호
    • 한국멀티미디어학회논문지
    • /
    • 제12권11호
    • /
    • pp.1557-1562
    • /
    • 2009
  • 단조프레스기의 유압실에서 배관의 연결부위의 손강으로 인한 누유는 인명피해와 기계 파손의 위험성이 있어 이를 조기에 발견하여 예방하는 시스템이 필요하다. 본 논문에서는 원격지에서 회전형 카메라를 이용하여 유압유의 누유여부를 자동 인식하는 시스템을 구현하였다. 구현한 시스템은 라벨링 과정에서 객체영역을 나타내는 경계사각형을 구하고 경계사각형의 높이와 폭에 대한 비율, 누유형상의 원형도를 이용하여, 올바른 누유영역을 추출하였다. 또한 잡음제거와 영상의 이동과 회전에 대한 보정을 전처리 과정으로 수행한다. 실험을 통하여 제안한 시스템이 여러 가지 조명 환경에서도 누유영역을 정확하게 찾아내는 것을 확인하였다.

  • PDF