DOI QR코드

DOI QR Code

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik (Department of Bio-based Materials, College of Agriculture and Life Science, Chungnam National University) ;
  • Ha, Been (Department of Bio-based Materials, College of Agriculture and Life Science, Chungnam National University)
  • Received : 2016.10.27
  • Accepted : 2016.12.09
  • Published : 2017.03.25

Abstract

Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

Keywords

References

  1. ASTM E 779. 2010. Standard test method for determining air leakage rate by fan pressurization. ASTM International.
  2. Choi, J.S., Ji, K.H., Lee, D.S., Jo, J.H. 2014. A study on uncertainty experiment depending on testers in airtightness measurement of buildings. Journal of Korean Institute of Architectural Sustainable Environment and Building Systems 8(2): 40-45.
  3. CAN/CGSB 149.10-M86. 1986. Determination of the airtightness of building envelopes by fan depressurization method. Canadian General Standard Board.
  4. Canada Mortgage and Housing Corporation. 1996. Energy audits of high-rise residential buildings. Research Highlights.
  5. Hong, B.J., Jun, J.Y., Kim, H.S. 1999. Experimental study on the air permeability of double glazing window in the apartment houses. Journal of the Architectural Institute of Korea Planning 15(4): 213-220.
  6. ISO 9972. 2015. Thermal performance of buildings - Determination of air permeability of buildings - Fan pressurization method. International Organization for Standardization.
  7. Ji, K.H., Shin, H.K., Jo, J.H. 2015. Measurement and comparison of the airtightness of an apartment building by the preparation in ISO 9972. Proceedings of the Architectural Institute of Korea 35(2): 239-240.
  8. JIS A 2201. 2003. Test method for performance of building airtightness by fan pressurization. Japanese Industrial Standards Committee.
  9. KEEI. 2015. Yearbook of energy statistics. Korea Energy Economics Institute.
  10. Kim, G.T., Yoo, J.H., Hwang, H.J., Kim, K.S. 2013. A study on the calculation method of infiltration for detached houses. Korea Journal of Air-Conditioning and Refrigeration Engineering 25(9): 493-498. https://doi.org/10.6110/KJACR.2013.25.9.493
  11. Kim, H.B., Kim, S.J., Oh, J.K., Park, J.S., Lee, J.J. 2012. Influence of air-tightness on heat energy performance in post and beam building with exposed wood frame. Journal of The Korean Wood Science and Technology 40(5): 319-326. https://doi.org/10.5658/WOOD.2012.40.5.326
  12. Kim, H.B., Park, J.S., Hong, J.P., Oh, J.K., Lee, J.J. 2014. Air tightness performance of residential timber frame buildings. Journal of The Korean Wood Science and Technology 42(2): 89-100. https://doi.org/10.5658/WOOD.2014.42.2.89
  13. Kim, S.J., Park, J.S. 2015. Factors of airtightness performance in timber frame buildings. Proceedings of The Korean Society of Wood Science and Technology Annual Meeting 256-257.
  14. Kim, S.S., Cho, S., Yoon, Y.J., Park, H.S. 2005. The study on the determining of the infiltration coefficient by window types. Journal of the Architectural Institute of Korea Planning 21(4): 183-189.
  15. Lee, S.B. 1995. An evaluation of airtightness performance and analysis of energy savings potential in apartment housing. Journal of the Korean Solar Energy Society 15(3): 119-125.
  16. Lee, K.H., Kim, S.M., Park, Y.H., Moon, J.S., Sohn, J.Y. 2005. A study on the air tightness performance and stack effect characteristics in high-rise apartments. Journal of the Architectural Institute of Korea Planning 21(12): 279-286.
  17. Lee, D.S., Ji, K.H., Jo, J.H. 2014. Study on the establishment of large building airtightness measurement standards. Journal of the Korean Solar Energy Society 34(1): 117-124. https://doi.org/10.7836/kses.2014.34.1.117
  18. Lee, S.I., Kim, J.G., Kim, S.H., Kim, J.H., Jeong, H.G., Jang, C.Y. 2015. An analysis of the airtightness performance and heating energy demand according to building structural characteristics - Focused on newly apartment houses. Journal of the Korea Institute of Ecological Architecture and Environment 15(2): 109-115.
  19. Lee, Y.G., Shin, C.W. 2013. The air leakage characteristics and airtightness performance of a newly built apartment. Korea Journal of Air-Conditioning and Refrigeration Engineering 25(11): 606-611. https://doi.org/10.6110/KJACR.2013.25.11.606
  20. Shin, H.K., Jo, J.H. 2011. Comparison of test conditions of the fan pressurization method in measuring the building airtightness. Journal of the Architectural Institute of Korea Planning 27(8): 279-286.
  21. Yoon, J.H., Park, J.W., Lee, K.S., Baek, N.C., Shin, U.C. 2008. A study on the measurement of airtightness performance of detached houses in Chung-cheong area. Journal of the Korean Solar Energy Society 28(5): 65-71.
  22. Yoon, J.O. 2013. Field measurement of infiltration in new apartments using de-pressurization method. Journal of the Korea Institute of Ecological Architecture and Environment 13(3): 27-32.