• Title/Summary/Keyword: Lifting effect

Search Result 192, Processing Time 0.028 seconds

The Combined Effect of Autologous Fat Injection and Liposculpture for Gluteal Reshaping in Koreans (한국인에 있어 둔부몸매교정(Gluteal Reshaping)을 위한 자가지방주입술 및 지방흡입술의 효과)

  • Kim, Jee-Hoon;Hong, Jin-Joo
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.861-866
    • /
    • 2011
  • Purpose: Together with the breast, buttocks are an important element of attractive body contour. To make a beautiful buttocks, improvement of body contour around the buttock as well as buttock augmentation and lifting is also important. The authors investigated characteristic features of buttocks in Koreans and report about the results of liposculpture and autologous fat injection for improving buttock's contour. Methods: We performed a retrospective study of 21 patients who would like to gluteal reshaping. We checked about buttock's ptosis, projection, depression, gluteal retraction and excessive fat accumulation around buttocks. Depending on it, we performed liposculpture and autologous fat injection. Under general anesthesia, we harvested fat from excessive fat accumulation areas around buttocks, and injected into buttocks medio-superiorly. Postoperatively, pillows were positioned on the bed not to press the buttocks which were injected with the fat. Results: Based on the shape of buttocks, A-shape is seen in 4 cases (19%), V-shape 3 cases (14%), squareshape 9 cases (43%), round-shape 5 cases (24%). Based on the Gonzalez's ptosis grading method, 1 degree ptosis is 1 case (4%), 2 degree ptosis is 6 cases (29%), 3 degree ptosis is 8 cases (38%), 4 degree ptosis is 6 cases (29%). There were no complications such as infection, hematoma, pain, dysparethesia. The subjective assessment of surgical results by patients was excellent. Conclusion: To make a beautiful buttock, improvement of body contour around the buttock as well as buttock augmentation and lifting is also important. Liposculpture and autologous fat grafting are very safe, useful and easy methods for improving buttock's contour.

Experimental and numerical study on coupled motion responses of a floating crane vessel and a lifted subsea manifold in deep water

  • Nam, B.W.;Kim, N.W.;Hong, S.Y.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.5
    • /
    • pp.552-567
    • /
    • 2017
  • The floating crane vessel in waves gives rise to the motion of the lifted object which is connected to the hoisting wire. The dynamic tension induced by the lifted object also affects the motion responses of the floating crane vessel in return. In this study, coupled motion responses of a floating crane vessel and a lifted subsea manifold during deep-water installation operations were investigated by both experiments and numerical calculations. A series of model tests for the deep-water lifting operation were performed at Ocean Engineering Basin of KRISO. For the model test, the vessel with a crane control system and a typical subsea manifold were examined. To validate the experimental results, a frequency-domain motion analysis method is applied. The coupled motion equations of the crane vessel and the lifted object are solved in the frequency domain with an additional linear stiffness matrix due to the hoisting wire. The hydrodynamic coefficients of the lifted object, which is a significant factor to affect the coupled dynamics, are estimated based on the perforation value of the structure and the CFD results. The discussions were made on three main points. First, the motion characteristics of the lifted object as well as the crane vessel were studied by comparing the calculation results. Second, the dynamic tension of the hoisting wire were evaluated under the various wave conditions. Final discussion was made on the effect of passive heave compensator on the motion and tension responses.

Muscle Strength Measurement using Shoulder and Upper Joint for Korean Young-aged (우리나라 청년층의 어깨 및 상지관절을 이용한 근력 측정)

  • Yoon, Hoon-Yong;Kim, Eun-Sik
    • Journal of the Ergonomics Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.125-134
    • /
    • 2009
  • The muscle strengths in various postures are used in our daily life with or without our recognition. Also, many works are still performed with strengths, although mechanization and automation have been fairly accomplished at the industry site. Since the late seventies, various body measurements have been conducted periodically in Korea, however, muscle strengths have not been measured actively. For this reason, the muscle strength data have been hardly accumulated. The aims of this study are to learn more about the physical strength of young-aged Koreans and to provide basic information for designing equipments, tools and facilities in the work site and daily life. The muscle strengths that are related to shoulder and upper limbs joints, which are used frequently, are measured in this study. Eighteen muscle strengths, from seven different movements such as elbow flexion, elbow extension, shoulder abduction(seated), shoulder adduction(seated), shoulder rotation(internal and external), lifting a tray, and turning a key(inward and outward) were measured. For every movement, the muscle strengths for both hands were measured. In each measurement, five seconds averaged value and peak value were collected. Comparing the average value, the strength of shoulder adduction was the strongest for male and female, while strength of turning a key inward with left hand was the weakest for male and female. Strengths of preferred hand in elbow extension, shoulder abduction, shoulder external rotation, lifting a tray, and turning a key were stronger than those of non-preferred hand for both male and female. Rohrer's index considerably had an effect on muscle strength. The results of this study can provide some basic information not only in designing the equipment and facilities in work site or daily life, but also in selection, training and management of workers.

Analysis of health inequality by the type of employment on health among employees - Pathway of the effect via the exposure of hazardous factors - (임금근로자의 고용형태에 따른 건강수준의 차이 분석 - 유해위험요인 노출을 경유한 영향 경로 -)

  • Rhee, Kyung Yong
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.81-90
    • /
    • 2014
  • Flexible production system has been expanded to all sectors of economy with the change of labor market and diversification of employment. The unstable employment with irregular work has replaced stable employment with regular work. This study has investigate the impact pathway of the type of employment on health status especially ill-health symptoms experiences. Among the first Korean Working Conditions Survey data, the employee's response data was used to analyze the path way with multiple regression analysis. The result has shown the direct effect of the type of employment on ill-health symptoms experience. Indirect effect of the type of employment was found the pathway via the exposure to noise, high temperature, low temperature, dust, skin contact to chemicals, painful posture, heavy material handling, standing position, repetitive movement of hands. However the exposure to the other hazardous factors such as organic solvent, wholebody vibration, radiation, lifting people, infectious materials were not influenced by the type of employment.

Effects of vortex generators on the wind load of a flat roof: A computational study

  • Zhao, Yagebai;Deng, Xiaolong;Zhang, Hongfu;Xin, Dabo;Liu, Zhiwen
    • Wind and Structures
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Vortex generators are commonly used in mechanical engineering and the aerospace industry to suppress flow separation owing to their advantages of simple structure, economic viability, and high level of efficiency. Owing to the flow separation of the incoming wind on the leading edge, a suction area is formed on the roof surface, which results in a lifting effect on the roof. In this research, vortex generators were installed on the windward surface of a flat roof and used to disturb to roof flow field and reduced suction based on flow control theory. Computational fluid dynamics (CFD) simulations were performed in this study to investigate the effects of vortex generators on reduce suction. It was determined that when the vortex generator was installed on the top of the roof on the windward surface, it had a significant control effect on reduce suction on the roof leading edge. In addition, the influence of parameters such as size, placement interval, and placement position of the vortex generator on the control effect of the roof's suction is also discussed.

The Effect of Elastic Tape on Lower Extremity Muscle Activity in Squats of Young Female Adults: A Cross-sectional Pilot Study

  • Namjeong Cho;Yangrae Kim
    • Physical Therapy Korea
    • /
    • v.30 no.3
    • /
    • pp.169-173
    • /
    • 2023
  • Background: In terms of physical performance, elastic tape (ET) is known to contribute to injury prevention and performance enhancement. Objects: This study aimed to compare and analyze the effect on lower extremity muscle activity of young adult women with and without ET during squats. Methods: In this study, six healthy, young women were recruited as participants in a university laboratory. Participants were allocated to two groups of three after measuring muscle activity in a pre-test, and the experiment was conducted for a total of two weeks (two sessions). First, 10 half squats were taped once in the first week, and 10 half squats were performed without taping in the second week. The other group did this in reverse and measured muscle activity after the squat was over. Results: As a result of this study, there was no significant difference in the quadriceps with or without ET (Z = -0.11, p > 0.05). Similarly, no significant difference was found in hamstring (Z = -0.31, p > 0.05). Conclusion: No beneficial effect was found on changes in muscle activity following ET application during squats. Further studies require randomized controlled trials that increase the number of participants and the intensity of the intervention, and measure pain, function, and performance rather than muscle properties depending on the biomechanical lifting mechanism.

Immobilization Effect and Abdominal Pressure of Newly-Developed Lumbosacral Spinal Orthosis during Task Performance (새롭게 개발한 요천추 보조기의 과제 수행 중 척추의 고정효과와 복부압력)

  • Jeon, Kyung Soo;Yang, Hee Seung;Jang, Soo Woong;Shin, Hee Dong;Lee, Yun kyung;Lee, Young;Lee, Seul Bin Na;Ahn, Dong Young;Sim, Woo Sob;Cho, Min;Cho, Kyu Jik;Park, Dong Beom;Park, Kwan Soo
    • Clinical Pain
    • /
    • v.19 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • Objective: We evaluated the efficacy of a newly-developed spinal orthoses (V-LSO) by comparing the stabilizing effect, abdominal pressure, and comfort of 3 different semirigid LSOs (classic LSO, V-LSO, and Cybertech®) during various body movements. Method: Thirty healthy volunteers (23~47 years, 24 males, 6 females) were selected. A dual inclinometer measured the range of motion (ROM) while the participants performed flexion/extension and lateral flexion of the lumbar spine with 3 LSOs. The LSO's pressure on the abdominal surface was measured using 9 pressure sensors while lying, sitting, standing, flexion/extension, lateral flexion, axial rotation, and lifting a box. Comfort and subjective immobilization were analyzed by a questionnaire. Results: V-LSO had a statistically significant effect on flexion over Cybertech®. No significant differences were noted during extension and lateral flexion between the 3 LSOs. The abdominal pressure showed no significant differences while supine. While sitting, standing, and lifting a box, the mean abdominal pressure for V-LSO were significantly higher than those for Cybertech®. During lumbar flexion, the mean abdominal pressures for classic LSO and V-LSO were significantly higher than that of Cybertech®. For extension, lateral flexion and axial rotation, the abdominal pressure for V-LSO was significantly higher than those of classic LSO and Cybertech®. In the subjective analysis, V-LSO and Cybertech® scored best for comfort. Conclusion: The V-LSO and Cybertech® were more comfortable than the classic LSO, and hence, may have improved compliance with decreased discomfort. V-LSO may be superior to the other LSOs in restricting lumbar movement and increasing intraabdominal pressure.

A Study on the Evaluation of Compression Force at the L5/S1 using Electromyography (근전도를 이용한 L5/S1에서의 요추부하 평가에 관한 연구)

  • 양성환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.323-332
    • /
    • 1997
  • This study evaluated the compression force at the L5/S1 disc using EMG(Electromyography). EMG signals were analyzed under the condition of fixed vertical factor (20Cm∼80Cm), two horizontal factors (35Cm, 55Cm), and two weight factors (10Kg, 25Kg) 2 times per minute for each posture. Also, the result was compared with the compression force of each posture which computated by the equation of NIOSH(National Institute for Occupational Safety and Health) guide to manual lifting(1991). The experimental result show that EMG signals have more an effect on the Weight than the Horizontal factors. Also, there are not significant differences on the analysis result of EMG signals between Health members and not, because the body buildings which doing Health members are not enhanced the motor unit due to the MMH(Manual Material Handing).

  • PDF

A Study on Multirate Control Using a Current Estimator (현재 상태 추정기를 이용한 멀티레이트 제어에 관한 연구)

  • 황희철;정정주;정동실
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.12
    • /
    • pp.1004-1013
    • /
    • 2002
  • A multirate state feedback control (MRSFC) method is proposed for systems sensitive to disturbance and noise based on the multirate estimator design using current estimator. MRSFC updates the controller output slower than the measurement sampling fiequency of system output by a lifting factor $R=T_c/T_s$ The closed-loop MRSFC system is less sensitive to disturbance and noise due to filtering effect than the conventional single-rate control system The multirate estimator gain can be obtained by solving a conventional pole placement problem such that MRSFC has the same spectrum of eigenvalues in the s-plane as the single-rate control. We applied the proposed multirate state feedback controller to a galvanometer servo system Simulation and experimental results show that settling and tracking performances are improved compared with a conventional single-rate pole placement control (PPC).

A Continuous Robust Control Strategy for the Active Aeroelastic Vibration Suppression of Supersonic Lifting Surfaces

  • Zhang, K.;Wang, Z.;Behal, A.;Marzocca, P.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.210-220
    • /
    • 2012
  • The model-free control of aeroelastic vibrations of a non-linear 2-D wing-flap system operating in supersonic flight speed regimes is discussed in this paper. A novel continuous robust controller design yields asymptotically stable vibration suppression in both the pitching and plunging degrees of freedom using the flap deflection as a control input. The controller also ensures that all system states remain bounded at all times during closed-loop operation. A Lyapunov method is used to obtain the global asymptotic stability result. The unsteady aerodynamic load is considered by resourcing to the non-linear Piston Theory Aerodynamics (PTA) modified to account for the effect of the flap deflection. Simulation results demonstrate the performance of the robust control strategy in suppressing dynamic aeroelastic instabilities, such as non-linear flutter and limit cycle oscillations.