• Title/Summary/Keyword: Life-stress

Search Result 6,116, Processing Time 0.034 seconds

An Analysis on Marathon Participants' Convergence Recognition about attending Marathon Activities in their 20s and 30s Using the Q Methodology (Q방법론을 활용한 20~30대 마라톤 동호회 활동 참가자의 마라톤 활동에 대한 융합적 인식 분석)

  • Yu, Young-Seol
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.9
    • /
    • pp.73-81
    • /
    • 2020
  • The purpose of this study was to analyze the recognition of 20s~30s' young people in marathon activities using Q methodology. P-sample was composed of 30 young marathoners. The selected Q samples were arranged in the normal distribution form. The collected data were analyzed by factor analysis through varimax rotation using QUANL 1.2PC program. Three distinct were emerged throughout the analysis: the first type is 'the type of giving special meaning.' which is improving their physical fitness, healthy and enjoying runner's high. The second type is 'the enjoying leisure' which is releasing stress and enjoying their common interest.' The last type is 'the type of enjoying crew activity.' which is enjoying marathon festival and managed their healthy and life. This result hints that young marathoners' sports culture trends.

FLIP CHIP ON ORGANIC BOARD TECHNOLOGY USING MODIFIED ANISOTROPIC CONDUCTIVE FILMS AND ELECTROLESS NICKEL/GOLD BUMP

  • Yim, Myung-Jin;Jeon, Young-Doo;Paik, Kyung-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.2
    • /
    • pp.13-21
    • /
    • 1999
  • Flip chip assembly directly on organic boards offers miniaturization of package size as well as reduction in interconnection distances resulting in a high performance and cost-competitive Packaging method. This paper describes the investigation of alternative low cost flip-chip mounting processes using electroless Ni/Au bump and anisotropic conductive adhesives/films as an interconnection material on organic boards such as FR-4. As bumps for flip chip, electroless Ni/Au plating was performed and characterized in mechanical and metallurgical point of view. Effect of annealing on Ni bump characteristics informed that the formation of crystalline nickel with $Ni_3$P precipitation above $300^{\circ}C$ causes an increase of hardness and an increase of the intrinsic stress resulting in a reliability limitation. As an interconnection material, modified ACFs composed of nickel conductive fillers for electrical conductor and non-conductive inorganic fillers for modification of film properties such as coefficient of thermal expansion(CTE) and tensile strength were formulated for improved electrical and mechanical properties of ACF interconnection. The thermal fatigue life of ACA/F flip chip on organic board limited by the thermal expansion mismatch between the chip and the board could be increased by a modified ACA/F. Three ACF materials with different CTE values were prepared and bonded between Si chip and FR-4 board for the thermal strain measurement using moire interferometry. The thermal strain of ACF interconnection layer induced by temperature excursion of $80^{\circ}C$ was decreased with decreasing CTEs of ACF materials.

  • PDF

Computer Simulation for Working Condition of Undergroundwork Using TOP DOWN Technique (TOP DOWN 지하공사의 작업환경체크 컴퓨터시물레이션에 관한 기초적 연구)

  • 고성석;손기상;심경수
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.96-105
    • /
    • 1995
  • The better industry develops, the more spaces need but in the limited area. Most building become larger and more complicated if the more spaces need in the constant area. And this leads to do underground work in long period generally six(6) months for 6 basement stories due to the selection of TOP DOWN technique. Working environment in this underground area can be problems and should not be overlooked, because air quality in underground spaces become quickly worse. Recently, department name to control construction safety has been changed to ENVIRONMENT & SAFETY TEAM from SAFETY TEAM. This means that it is very important to control against environmental condition at site so much. Overall construction work as well as underground work should conform to the requirement of working environment, particularly against inhabitants around the construction area. Strut protection, one of earth protection method, in case to 40m long strut may become weaker due to thermal stress or its longitudinally compressive strain and the another one, earth anchor protection may not be applied to the site In case of encroaching on vertical underground borderline because of regulation to prohibit it. It is necessary that TOP DOWN technique should be introduced in order to solve the external and internal problem of the site such as difficulty level of the work, potential danger with excavating depth, and shortening workperiod. It is needed that improving way of working condition should be shown and simplified computer simulation program should be also provided for checking pollution level & ventilation, excluding of lighting problem here. Results measured with conformance to the Regulation for Working Environment Measurement, enforced by Ministry of Labor have been applied to the computer program developed here. Sample air taken at unit workplace which was considered as exposing condition of pollutant at breathing point and within a range of behavior of the workers, Identified exposing group in underground work, using Moded Flow Life Finally, three types of ventilation system, type I with blower & ventilator, type II natural supply with mechanical ventilation system, and type I mechanical ventilation with Drivent Fan Unit System are selected for this study.

  • PDF

Comparison of Storage Lifetimes by Variance Assumption using Accelerated Degradation Test Data (파괴적 가속열화시험 데이터의 분산가정에 따른 수명비교)

  • Kim, Jonggyu;Back, Seungjun;Son, Youngkap;Park, Sanghyun;Lee, Moonho;Kang, Insik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.173-179
    • /
    • 2018
  • Estimating reliability of a non-repairable system using the degradation data, variance assumption such as homogeneity (constant) or heteroscedasticity (time-variant) could affect accuracy of reliability estimation. This paper showed reliability estimation and comparison results under normal conditions using accelerated degradation data obtained from destructive measurements, according to variance assumption of the data at each measurement time. Degradation data from three accelerated conditions with stress factors of temperature and humidity were used to estimate reliability. The $B_{10}$ lifetime was estimated as 1243.8 years by constant variance assumption, and 18.9 years by time-variant variance. And variance assumption provided different analysis results of important stresses to reliability. Thus, accurate assumption of variance at each measurement time is required when estimating reliability using degradation data of a non-repairable system.

Identification and Characterization of a New Strain of the Unicellular Green Alga Dunaliella salina (Teod.) from Korea

  • Polle, Jurgen E.W.;Struwe, Lena;Jin, Eon-Seon
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.821-827
    • /
    • 2008
  • The unicellular green alga Dunaliella salina is a halotolerant eukaryotic organism. Its halophytic properties provide an important advantage for open pond mass cultivation, since D. salina can be grown selectively. D. salina was originally described by E. C. Teodoresco in 1905. Since that time, numerous isolates of D. salina have been identified from hypersaline environments on different continents. The new Dunaliella strain used for this study was isolated from the salt farm area of the west coastal side of South Korea. Cells of the new strain were approximately oval- or pear-shaped (approximately $16-24\;{\mu}m$ long and $10-15\;{\mu}m$ wide), and contained one pyrenoid, cytoplasmatic granules, and no visible eyespot. Although levels of $\beta$-carotene per cell were relatively low in cells grown at salinities between 0.5 to 2.5 M NaCl, cells grown at 4.5 M NaCl contained about a ten-fold increase in cellular levels of $\beta$-carotene, which demonstrated that cells of the new Korean strain of Dunaliella can overaccumulate $\beta$-carotene in response to salt stress. Analysis of the ITS1 and ITS2 regions of the new Korean isolate showed that it is in the same clade as D. salina. Consequently, based on comparative cell morphology, biochemistry, and molecular phylogeny, the new Dunaliella isolate from South Korea was classified as D. salina KCTC10654BP.

The relationship between subjective body shape perception, health factors, and oral health factors among Korean adolescents - based on the 2015 Korea Youth Risk Behavior Web-Based Survey - (한국 청소년의 주관적인 체형 인식과 건강요인 및 구강건강요인과의 관련성 - 2015년 청소년건강행태온라인조사를 바탕으로 -)

  • Lee, Kyeong-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.5
    • /
    • pp.827-840
    • /
    • 2017
  • Objectives: The purpose of this study was to investigate the relationship between demographic characteristics, health factors, oral health factors and subjective body shape perception of adolescents in order to provide basic data for adolescents health management. Methods: This study was analyzed using Korea Youth Risk Behavior Web-Based Survey in 2015, where 68,043 adolescents in total participated. Data were analyzed by SPSS Ver. 21.0. Multiple regression analysis was used to analyze the relationships among health factors and oral health factors related to subjective body shape perception. Results: The analysis of the factors influencing the body shape perception of male adolescents showed that they tend to be low in school performance, low in family economic level, and high school students. The worse they perceive their subjective health to be, the more they feel stress, and the less frequently they brush their teeth per day. They had bad breath. The analysis of the factors influencing the body shape perception of female adolescents showed that they tend to be low in school performance, low in family economic level, and high school students. The worse they feel their subjective health is, the more they feel unhappy, and stressful, and the less frequently they brush their teeth per day. They feel pain during chewing, and have bad breath. Conclusions: In conclusion, it is necessary to consider educational intervention in adolescent life that will make them have proper perception of their body shape for proper health management of it. To make the intervention effective, we need to consider various factors such as health factors and oral health factors.

Janus Kinase 2 Inhibitor AG490 Inhibits the STAT3 Signaling Pathway by Suppressing Protein Translation of gp130

  • Seo, In-Ae;Lee, Hyun-Kyoung;Shin, Yoon-Kyung;Lee, Sang-Hwa;Seo, Su-Yeong;Park, Ji-Wook;Park, Hwan-Tae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.2
    • /
    • pp.131-138
    • /
    • 2009
  • The binding of interleukin-6 (IL-6) cytokine family ligands to the gp130 receptor complex activates the Janus kinase (JAK)/ signal transducer and activator of transcription 3 (STAT3) signal transduction pathway, where STA T3 plays an important role in cell survival and tumorigenesis. Constitutive activation of STAT3 has been frequently observed in many cancer tissues, and thus, blocking of the gp130 signaling pathway, at the JAK level, might be a useful therapeutic approach for the suppression of STAT3 activity, as anticancer therapy. AG490 is a tyrphostin tyrosine kinase inhibitor that has been extensively used for inhibiting JAK2 in vitro and in vivo. In this study, we demonstrate a novel mechanism associated with AG490 that inhibits the JAK/STAT3 pathway. AG490 induced downregulation of gp130, a common receptor for the IL-6 cytokine family compounds, but not JAK2 or STAT3, within three hours of exposure. The downregulation of gp130 was not caused by enhanced degradation of gp130 or by inhibition of mRNA transcription. It most likely occurred by translation inhibition of gp130 in association with phosphorylation of the eukaryotic initiation factor-2 a. The inhibition of protein synthesis of gp130 by AG490 led to immediate loss of mature gp130 in cell membranes, due to its short half-life, thereby resulting in reduction in the STAT3 response to IL-6. Taken together, these results suggest that AG490 blocks the STAT3 activation pathway via a novel pathway.

A Study on the Symbolic Recognition Structure System of Space Design of a Hotel (호텔 공간디자인의 상징적 인식구조체계에 관한 연구)

  • Kim, Jeong-Ah;Kim, Uk
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.4
    • /
    • pp.92-101
    • /
    • 2008
  • A new paradigm of design lays stress on the world of metaphysical concepts, and various attempts are being made to give meaning to psychological values. Hotel is a memorable place to remind of a special moment in one's life such as travel, marriage, meeting and so on. It also contains even more symbolism than other spaces as it is the place where the most primary and private act takes place apart from one's residence. As a result, it is also possible to communicate the message which a designer intends to convey through the user's recognition in the form of various symbolic expressions in space design. The designer communicates a meaning into a space through a symbolic system and creates a mutual consensus by means of the understanding structure of "designer-space-user". The user's diverse interpretations through a symbol are based on epistemology and consist of the primary, the secondary and the tertiary recognition structure system in the aspect of their contents. The primary structure depends on sensual perception, impressive idea and transcendental recognition based on metaphysical and perceptional association. The secondary structure includes casualty, continuous deduction and rational(integral) recognition. Finally, the tertiary structure is sublimation to the transcendental mental world beyond the boundary of emotion and it is classified into fundamental recognition structure on an object and archetypical recognition structure on an ego. These characteristics can derive systematic understandings and diverse interpretations on the symbol from the space of a hotel through the frame of analysis based on the artistic form of monosemous, polysemous and multidimensional frameworks and symbols. The framework of this analysis includes all the cases, and various methods which haven't been attempted in practice are presented. Therefore this study is not just a simple analysis of space but rather it will serve as a methodological tool for design that allows for various attempts of symbolic design concepts in the recognition structure system.

Comparison and Review of Fatigue Design Criteria by the Structural Analysis of Steel Truss Bridges (강재 트러스교의 해석에 의한 피로설계기준 비교 및 검토)

  • Kim, Sang-Seog;Jung, Hie-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.241-249
    • /
    • 2003
  • The service life of steel bridges can be assured only when their strength, serviceability and fatigue safety are fulfilled. However, at the present time, the continuous research for fatigue of steel bridges is desperately required since not much research work has been done so far. In this study, a guideline on the fatigue design is suggested for the practical purpose in order to establish the long-term safety of steel bridges against fatigue. The continuous steel truss bridge was analyzed for the cumulative reversals of the actual traffic, stress ranges and fatigue strength. From the results, the domestic fatigue design procedure was found to be fairly overestimated in comparison to the design code of other foreign countries. Therefore, it is necessary to review the current fatigue design specifications and have the new and rationalized design criteria in the future domestic fatigue design guidance.

Power Factor Correction LED Driver with Small 120Hz Current Ripple (낮은 120Hz 출력 전류 리플을 갖는 역률개선 LED 구동 회로)

  • Sakong, Suk-Chin;Park, Hyun-Seo;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.91-97
    • /
    • 2014
  • Recently, the LED(Light Emitting Diode) is expected to replace conventional lamps including incandescent, halogen and fluorescent lamps for some general illumination application, due to some obvious features such as high luminous efficiency, safety, long life, environment-friendly characteristics and so on. To drive the LED, a single stage PFC(Power Factor Correction) flyback converter has been adopted to satisfy the isolation, PFC and low cost. The conventional flyback LED driver has the serious disadvantage of high 120Hz output current ripple caused by the PFC operation. To overcome this drawback, a new PFC flyback with low 120Hz output current ripple is proposed in this paper. It is composed of 2 power stages, the DCM(Discontinuous Conduction Mode) flyback converter for PFC and BCM(Boundary Conduction Mode) boost converter for tightly regulated LED current. Since the link capacitor is located in the secondary side, its voltage stress is small. Moreover, since the driver is composed of 2 power stages, small output filter and link capacitor can be used. Especially, since the flyback is operated at DCM, the PFC can be automatically obtained and thus, an additional PFC IC is not necessary. Therefore, only one control IC for BCM boost converter is required. To confirm the validity of the proposed converter, theoretical analysis and experimental results from a prototype of 24W LED driver are presented.