• Title/Summary/Keyword: Lens color

Search Result 158, Processing Time 0.031 seconds

Design of a Catadioptric System with Corrected Color Aberration and Flat Petzval Curvature Using a Graphically Symmetric Method

  • Lim, Tae-Yeon;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • 제2권4호
    • /
    • pp.324-331
    • /
    • 2018
  • This paper describes a symmetric method for determining a combination of element power and optical material to design a catadioptric system with corrected color aberration and flat Petzval curvature. To graphically obtain the solutions, a glass chart containing the Abbe number, the refractive index, and the optical power, which are closely related to these aberrations, is suggested. First, we recompose an optical system as a doublet of the specific lens and an equivalent single lens, and then locate both lenses on lines that are symmetric to each other on a glass chart, through changing the lens parameters effectively. Utilizing this method, an achromatic catadioptric system with flat Petzval curvature is obtained.

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • 한국임상보건과학회지
    • /
    • 제7권1호
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

Development of Image-space Telecentric Lens for Intra-Oral 3D Scanner

  • Kim, Tae Young;Shin, Min-Ho;Chang, Ryungkee;Kim, Young-Joo
    • Journal of the Optical Society of Korea
    • /
    • 제19권3호
    • /
    • pp.303-310
    • /
    • 2015
  • An image-space telecentric lens for an intra-oral 3D scanner was designed and fabricated for dental application. Since a telecentric function can provide the same results regardless of image plane position, it helps to realize a more accurate image for an intra-oral scanner. The performance of the designed lens meets the required properties for HD resolution. In particular, lateral color is corrected within 1 pixel. This system achieves depth of focus of more than 3 mm. For user convenience, the developed system consists of a prism part and an imaging part. Both parts are optimized to reduce the front size and weight of the system. In order to make the parallax sights, parallax angle was determined to be 8 degrees between two optical systems.

Design and Simulation of White Color Mixing Lens for Backlight Unit

  • Hwang, Sung-Kyung;Lim, Mee-Hyun;Han, Hae-Wook;Cho, Min-Su;Lee, Jae-Ho;Jang, Kyeng-Kun;Kang, Sin-Ho;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.229-230
    • /
    • 2009
  • This paper proposes a new design of ultra-slim color mixing lens (CML) for backlight unit (BLU), and presents simulated performance of the design. The novel color mixing structure has a shorter mixing length (< 1cm) than the existing color mixing structure, and achieves high efficiency and uniformity.

  • PDF

증착 물질 두께 조절을 이용한 색상 렌즈 설계 (Color Lens Design by Changing the Combination of Coating Materials)

  • 이덕희;류지욱;한두희
    • 한국산학기술학회논문지
    • /
    • 제3권2호
    • /
    • pp.84-88
    • /
    • 2002
  • SiO₂와 ZrO₂를 코팅물질로 사용하는 안경 렌즈의 5층 코팅을 설계하였다. 제5층의 두께를 변화시키면서 반사율을 계산하고, RGB의 반사율을 이용하여 반사된 빛의 색상을 시각화하였다. 그 결과 5층의 두께가 5nm부터 80nm까지 점점 두꺼워지면서 반사광의 붉은 색상이 점점 감소하였고 80nm에서 점점 두꺼워질수록 푸른 색상이 증가하였다. 색상의 분석은 Photoshop 5.0을 이용하였다.

  • PDF

시간의 노화에 따른 Yellow와 Blue에 대한 색지각 특성 (Characteristics of Color Perception about Yellow and Blue with Human Lens Coloration)

  • 이윤재
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.168-172
    • /
    • 2006
  • With the progress of the aging society into the aged society, the planning of senior housing is inevitably required. Among the factors of planning, color appeals to people's vision which mostly accepts information about the environment, so age-related color vision changes should be studied. The purpose of the study is to find out characteristics of color perception focused on yellow and blue with advancing of the yellowed eye sight in the old age. The findings are as follows. (1) Regardless of gender, losses of color perception in sensitivity is occurred as aging is proceeded. But the rate of reduction is mitigated compared with the ex-research in Japan because of the promotion of physical health. (2) Human lens coloration was not common until 85 years old and the hue of yellow and red was easily perceived by the older subjects. (3) Yellow is more preferred to other colors by the elderly and accuracy of yellow-color perception is higher than that of blue-color. (4) It is especially hard for the elderly to perceive the difference between pure blue and mixture of blue-green. Therefore blue and blue-green should not be adopted simultaneously in senior housing environment. Except for the space which specially requires carefulness, various color preferred by the elderly should be applied to the senior housing environment to satisfy their psychological condition and provide the vitality of life.

  • PDF

소프트 콘택트렌즈 착용자의 실태와 문제점 (The State and Problem of the Soft Contact Lens Wearer)

  • 김덕훈;황선영
    • 한국안광학회지
    • /
    • 제3권1호
    • /
    • pp.249-258
    • /
    • 1998
  • 소프트 콘택트렌즈의 착용자에 대한 실태와 문제점에 대한 결과는 다음과 같다. 1. 최초의 콘택트렌즈 착용자의 가장 많은 연령층은 19세이며, 가장 먼저 착용한 연령은 15세이고, 가장 늦게 착용한 연령은 26세이다. 2. 처음 콘택트렌즈의 착용할 때의 시력검사 장소는 대게 안경원이다. 3. 현재 사용하고 있는 콘택트렌즈의 구입처는 대부분 안경원이다. 4. 현재 사용하고 있는 렌즈는 거의 소프트 렌즈이다. 5. 현재 사용하고 있는 렌즈의 생산국은 국내생산이 가장 많고, 모르는 것, 그리고 외국생산품 있다. 6. 콘택트렌즈 착용 후 시력을 알고 있는 사람은 거의 적으며, 특히 양안 시력을 알고 있는 사람은 특히 드물다. 7. 현재 사용하고 있는 소프트 콘택트렌즈의 색깔에 대해서는 10대에서는 무색이 가장 많고, 20대에서는 유색이, 그리고 30대에서는 거의 모르고 있다. 8. 소프트 콘택트렌즈의 장점에 대해서는 10대와 20대에서는 한 개정도, 30대에서는 전혀 모르는 것이 가장 많았다. 9. 소프트 콘택트 렌즈의 단점에 대해서는 10대와 30대에서는 한 개이나, 20대에서는 2개 정도 알고 있는 것이 가장 많았다. 10. 소프트 콘택트렌즈의 착용에 대한 부작용에 대해서는 10대에서는 한가지, 20대와 30대에서는 전혀 모르는 것이 가장 많았다. 11. 소프트 콘택트렌즈의 착용자에 대한 주요 자각증상에 대해서는 모두 7가지가 있으나, 전혀 자각증상이 없는 것이 가장 많고, 다음은 잘모르는 것, 그리고 자각증상이 있는 것에서는 통증이 가장 많았다. 12. 현재 착용하고 있는 소프트 콘택트렌즈의 부작용이 있는 렌즈의 현미경적 표면 조사에서는 렌즈의 파손, 렌즈의 중첩, 이물질의 침착 등이 주로 나타났다. 이상의 연구에서 현재 착용하고 있는 렌즈는 대게 소프트 렌즈이며, 구입처는 안경원이며, 소프트 렌즈에 대한 피검자의 지식과 시력에 대한 지식은 아주 적은 편이다. 따라서 현실적으로 볼 때에 안경사의 소프트렌즈에 대한 관리 및 취급을 할 수 있도록 법적 또는 교육적 지원이 있어야 한다고 생각된다.

  • PDF

Luminance와 동공크기 변화에 따른 렌즈에서 UV 차단효과 연구 (Study of UV-cut Effect by Luminance and Size of pupil in lens)

  • 김용근
    • 한국안광학회지
    • /
    • 제6권2호
    • /
    • pp.17-21
    • /
    • 2001
  • 렌즈에서 UV-A 선 차단 효율을 평가하기 위해 투과율에 의한 가시광 영역 luminance와 luminance에 의한 동공크기를 분석하였다. Luminance(L)에 따른 동공크기(${\Phi}$)는 ${\Phi}=d-e{\cdot}tanh(f{\cdot}logL)$로 주어지고, 동공 크기 (r)에 따른 투과효율은 $T_r(r)=1-gr^2+hr^4$으로 주어진다. $320{\sim}400nm$ 파장 영역인 UV-A에 대한 절대 차단 효율 ${\alpha}$와 제거 지수 $b=(1-{\alpha}){\times}100%$의 식을 유도하였다. UV-cut Lens, CR-39, red color 및 blue color 렌즈에 대한 ${\alpha}$ 값은 각각 0.018, 0.31, 0.273 및 0.153을 얻었고, b값은 각각 98, 69, 72 및 85%을 얻었다.

  • PDF

시각적 기능개선을 위한 LED 센서 등기구 설계 (A Design of an LED Sensor Luminaire for Visual Function Improvement)

  • 서정남;유용수;여인선
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.134-137
    • /
    • 2010
  • An LED sensor luminaire for visual function improvement necessitates the control algorithm for light level adjustment and the appropriate lens design. The control algorithm adapts to surround lighting condition, and thus has the advantages of energy saving and glare reduction. The multi-cell lens design improves color temperature uniformity and spatial light distribution of the luminaire. Experimental and simulated results show that this approach contributes noticeably to energy saving and color temperature uniformity of the LED sensor luminaire.

칼라필터 렌즈에 따른 대비감도의 변화 (Change of Contrast Sensitivity Induced by Tinted Spectacle Lens)

  • 서재명
    • 한국안광학회지
    • /
    • 제21권1호
    • /
    • pp.47-51
    • /
    • 2016
  • 목적: 칼라 필터렌즈를 사용하여 대비감도의 변화를 알아보고 임상에 필요한 매뉴얼을 제시하고자 하였다. 방법: 정상 시각을 가진 성인 남녀 20명을 대상으로 황색, 오렌지색, 녹색 필터렌즈를 사용하여 대비감도를 측정했다. 다섯 개의 공간주파수 2, 4, 6, 8, 10 cpd를 사용하였으며 표적의 노출시간은 33 ms, 233 ms로 설정했다. 결과: 대비감도는 전체적으로 표적의 노출시간이 짧은 33 nm보다 233 ms에서 높게 나타났다(p<0.05). 순간적인 노출(33 ms)에서 대비감도가 가장 높게 나타난 필터렌즈는 2 cpd에서의 황색(1.75 log unit)이었으나 233 ms에서는 8 cpd에서 필터를 삽입하지 않았을 때(1.85 log unit)가 가장 예민한 것으로 나타났지만 황색, 오렌지색 간 차이는 서로 근소하여 통계적 의미는 없었다(p>0.64). 결론: 색수차와 산란현상을 감소시켜 시기능을 개선시키는 황색 계열의 필터렌즈는 시기능 개선을 위한 다양한 목적으로 처방이 되고 있다. 필터렌즈를 처방하기에 앞서 cut off 파장을 고려한 필터렌즈의 특성을 파악하고 사용자의 특성과 필터렌즈의 사용 목적을 분명하게 확인할 것을 제안하는 바이다.