• Title/Summary/Keyword: Lee Ha-Bok

Search Result 446, Processing Time 0.035 seconds

Critical Speeds Evaluation of Turbo Pump Unit with a Elasticring Inserted Ball Bearing (탄성 링을 갖는 볼 베어링 지지의 터보 펌프 임계 속도에 관한 연구)

  • Lee, Yong-Bok;Kim, Chang-Ho;Kwak, Hyun-Duck;Ha, Tae-Woong;Yoo, Woo-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.2 s.11
    • /
    • pp.22-28
    • /
    • 2001
  • This study was performed to evaluate the dynamic behavior of turbo pump unit. The acceptable separate margin of $1^{st}$ critical speed was obtained by the use of elastic-ring inserted ball bearing, while the poor separate margin of $1^{\st}$ critical speed was appeared in the case without the elastic-ring. In addition, the results show that the stiffness and damping of plain seals give more separate margin of $2^{nd}$ critical speed. However the wear or the failure of seals could reduce the $2^{nd}$ critical speed near the operating speed.

  • PDF

A Study on the Rotordynamic Stability of Turbo Pump Unit

  • Kwak, Hyun-Duck;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Woong;Yoo, Woo-Chul
    • KSTLE International Journal
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • A turbo pump unit provides high pressure oxygen and fuel in a space shuttle main engine (SSME). This paper focused on rotordynamics, investigating its characteristics based on a numerical simulation of turbo pump finite element model. Speeds up to 50,000 rpm are considered, as well as the special problems related to elastic-ring, seal hydrodynamic force, shroud force and clearance-excitation farce. The rotordynamic prediction shows that the elastic-ring which is inserted between the casing and the outer race of ball bearing allows far an acceptable separate margin of first critical speed. Additionally, the results show that the floating ring seal, which have a peculiar ring, adds substantial stiffness and damping to the system as well as exhibits superior performance in terms of rotordynamic stability of system compared to the plain seal.

The Characteristic of Floating Ring Seal with Modified Geometry Configuration (기하학적 형상 변경에 따른 플로팅 링 실의 특성 연구)

  • Kim, Kyoung-Wook;Kim, Chang-Ho;Ha, Tae-Wong;Lee, Yong-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1142-1148
    • /
    • 2006
  • The floating ring seal which is used in the high pressure turbo pump is frequently used in the oxidizer pump and the fuel pump of the turbo pump of the liquid propulsion rocket, because it is able to minimize clearance to decrease the leakage flow rate. But, floating ring seal has a tendency to increase the force which caused instability of system as the eccentricity ratio increases. In this paper, we devised design of floating ring seal which decrease contact area between floating and supporting ring. Modified floating ring seal has a tendency to decrease the eccentricity ratio compare with original floating ring seal. The whirl frequency ratio which is able to distinguish stability of system decrease compare with original floating ring seal

  • PDF

A Case of Acute Isolated Bilateral Internal Ophthalmoplegia Associated with Anti-GQ1b IgG Antibody (항 GQ1b 항체와 연관된 급성 단독 양안성 내안근마비 1예)

  • Kim, Jae-Ha;Lee, Kyung-Bok;Roh, Hakjae;Ahn, Moo-Young;Jung, Du-Shin
    • Annals of Clinical Neurophysiology
    • /
    • v.8 no.1
    • /
    • pp.78-80
    • /
    • 2006
  • Miller-Fisher syndrome, Guillain-Barre syndrome with ophthalmoplegia, Bickerstaff s brainstem encephalitis and acute ophthalmoplegia share some clinical features, and common anti-GQ1b IgG antibody and these are introduced as anti-GQ1b antibody syndrome. These syndromes mostly present with paralysis of extraocular muscles and internal ophthalmoplegia rarely occurs. We report a case of acute isolated bilateral internal ophthalmoplegia associated with anti-GQ1b IgG antibody.

  • PDF

Coating using chitosan as a means to prevent dispersion of moist pellet feed in water of aquacultural farm, and bacterial pollution and its lipid oxidation during storage

  • Lee, Ki-Wan;Jeon, You-Jin;Heo, Moon-Soo;Song, Choon-Bok;Ha, Jin-Hwan;Kim, Se-Kwon
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.10a
    • /
    • pp.149-150
    • /
    • 2001
  • A fish feed being used most widely in aquacultural farm is a moist pellet (MP) feed which has been being prepared by mixing of commercial dry feed and nutritional oil to raw fish ky. The two major problems in the use of MP feed is to be readily dispersed in water of an aquacultural farm, and to cause lipid oxidation and bacteria infection during storage. The former induce an environmental pollution of the farm and the latter lower nutritional values and develop fish diseasees. (omitted)

  • PDF

Arc Fusion Protection of Covered Conductors Using AFPD (섬락 단선 방지 장치에 의한 피복 절연 가공배전 선로의 유도뢰애 의한 단선 방지)

  • Lee, Yong-Han;Jung, Dong-Hak;Ha, Bok-Nam;NamKung, Do;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.800-802
    • /
    • 1997
  • After flashover occurs on the overhead distribution line by lighting strokes(direct or induced), the power frequency arc current continues. If lightning flashover occurs on the overhead lines using covered conductors, the power frequency art current with fixed path overheats the conductor, and arc fusion fault can be occurred. There are two categories protecting or reducing methods of arc fusion faults caused by lightning stokes. - Reducing lightning flashover rate : G/W, LA, etc. - Protection by AFPD(Arc Fusion Protection Device) : power follow current interruption. This paper presents lightning surge phenomena on overhead distribution lines and protecting performance of arc fusion Protection devices to the lightning strokes nearby overhead line.

  • PDF

The Field Test of Feeder Automation using Fault Indicator having the information of fault current flowing (고장전류 통전정보를 갖는 Fault Indicator를 이용한 선로자동화 실증시험)

  • Ha, Bok-Nam;Park, Sang-Man;Lee, Jung-Ho;Cho, Nam-Hun;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.758-760
    • /
    • 1997
  • For feeder automation function, we must have Fault Indicator with the information of fault current flowing inside automatic feeder switches. In this paper, we introduce the algorithm of feeder automation, the theory of fault indicator, the result with some troubles of field test in real distribution system and contents of improvement.

  • PDF

The Study on the Automated Meter Reading using Low Voltage Power (저압 배전선 반송 방식의 원격검침 실증 연구)

  • Park, Sang-Man;Ha, Bok-Nam;Lee, Joong-Ho;Cho, Nam-Hun;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.985-987
    • /
    • 1997
  • AMR(Automated Meter Reading) has been considered to solve the lack of meter mem caused by the rise of cost, inefficiency of manual meter reading. Demand forecasting and efficient management of facilities can be accomplished by increasing meter reading efficiency and correcting various data. In this paper, we introduce AMR system using LV PLC in KANG-DONG blanch office of KEPCO.

  • PDF

Comparisons between Analysis and Experiment for Leakage Flowrate and Stability depending on the Effect of the Height and the Length of Floating Ring Seal (플로팅 링 실의 길이와 높이 효과에 따른 누수 및 안정성에 대한 해석과 실험의 비교)

  • An, Kyoung-Min;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Woong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.329-336
    • /
    • 2004
  • The lock-up position of the floating ring seal affects the leakage flowrate and the stability. And it is changed depending on the operating and geometry condition. In this paper, the leakage flowrate and stability with change of the height and length were investigated by theoretical analysis and experiment. The parameter of the height and length is expressed to the b and L. The decreasing of the b resulted in the increasing of equivalent whirl frequency ratio in the experimental result at the low speed and high pressure not such as theoretical analysis. As the L increased the leakage flowrate decreased and stiffness and direct damping coefficient increased in the experimental result. That was similar to the theoretical analysis.

  • PDF