• 제목/요약/키워드: Lead Length

검색결과 497건 처리시간 0.021초

적층형 고온초전도 전류도입선의 열 특성 해석 (Heat Characteristic Analysis of Stacking Type HTS Current Lead)

  • 두호익;임성우;홍세은;윤기웅;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.628-631
    • /
    • 2001
  • Current lead is one of the first proposed devices for the application of High Temperature-Superconductor(HTSC). The current lead provides high current for electrical machine using superconductor from room temperature. Its characteristics that is zero resistance and low heat transfer rate under critical temperature lead to research for the replacement of existing current lead with HTSC. In this paper, we investigated the temperature distributions of stacking type and rod type current lead with each cross-section area and length using Nastran program and compared each temperature distribution. It is obtained from this paper that stacking type current lead has flat temperature gradient and than rod type one and more stable operation as current lead is closely related with its cross-section area and length.

  • PDF

Direct Measurement of Diffusion Length in Mixed Lead-halide Perovskite Films Using Scanning Photocurrent Microscopy

  • Kim, Ahram;Son, Byung Hee;Kim, Hwan Sik;Ahn, Yeong Hwan
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.514-518
    • /
    • 2018
  • Carrier diffusion length in the light-sensitive material is one of the key elements in improving the light-current conversion efficiency of solar-cell devices. In this paper, we measured the carrier diffusion length in lead-halide perovskite ($MAPbI_3$) and mixed lead-halide ($MAPbI_{3-x}Cl_x$) perovskite devices using scanning photocurrent microscopy (SPCM). The SPCM signal decreased as we moved the focused laser spot away from the metal contact. By fitting the data with a simple exponential curve, we extracted the carrier diffusion length of each perovskite film. Importantly, the diffusion length of the mixed-halide perovskite was higher than that of the halide perovskite film by a factor of 3 to 6; this is consistent with the general expectation that the carrier mobility will be higher in the case of the mixed lead-halide perovskites. Finally, the diffusion length was investigated as a function of applied bias for both samples, and analyzed successfully in terms of the drift-diffusion model.

C/H 철탑 종단접속함 보호용 피뢰기 리드선 길이에 따른 뇌과전압 분석 (Analysis on Lightning Overvoltage According to Lead Length of Surge Arrester for Underground Cable Outdoor Termination Protection at C/H Tower)

  • 정채균;강지원
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.257-263
    • /
    • 2016
  • This paper describes the lightning arrester transients in cable head termination. The installation references of cable head tower and lightning arresters are firstly reviewed, then the performance of lightning arrester operation is also evaluated based on lightning overvoltage analysis by the change of grounding lead cable length. This paper finally proposes the optimal length of grounding lead cable at the cable head termination. The limited lightning current is also proposed according to the change of grounding lead cable length. The results will contribute to protecting insulation breakdown failure against lightning surge at the terminations and joints.

안전율이 일정한 초전도 전류도입선의 안정성해석 (Stability Analysis ofn HTS Current Lead with Constant Safety Factor)

  • 설승윤
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.15-19
    • /
    • 2000
  • The stability of variable cross-sectional area HTS current lead is considered. The cross-sectional area is varied to have a constant safety factor which is defined as the ratio of operating current and critical current of superconductor. As the constant area HTS lead, the variable cross-sectional area HTS lead also has three steady states above the bifurcation point and only one steady state below the bifurcation point. The temperature profiles and current sharing ratios for each steady state are calculated. The heat dissipation into cryogenic system for super-conducting, intermediate, and upper states are compared. For Bi-2333 sheathed with silver-gold alloy 2m length of current lead, and the maximum temperature of upper state seems to be burn-out free below 5m length.

  • PDF

전자현미경 In-Situ 관찰방법을 이용한 황동의 절삭성평가 (Estimation of Machinability of Lead Brass Based on In-Situ Observation in Scanning Electron Microscope)

  • 정승부;임옥동;안성욱
    • Applied Microscopy
    • /
    • 제24권3호
    • /
    • pp.87-93
    • /
    • 1994
  • In order to elucidate the machinability of lead brass, orthogonal machining experiment was conducted in SEM(Scanning Electron Microscope) equipped with a micro-machining device at a cutting speed of $7{\mu}m/s$ for brass containing 0.2 to 3wt% Pb. The microfactors (i.e., shear angle, contact length between chip and tool) were determined by in-situ observations. Machinability of brass containing lead is discussed in terms of the microfactors and the cutting resistant force tested by lathe cutting. The dynamic behavior of the chip formation of lead brass during the machining process was examined: The chips of lead brass form as a shear angle type. The shear angle increases with the content of lead in (6:4) brass. The pronounced effect of lead on the contact length between chip and tool was observed above 1% Pb. The cutting resistant force tested by lathe decreases remarkably with the lead content in brass. The observed microfactors are in close relation to the tested resistant force in macromachining.

  • PDF

3차원 납 접합부 형상을 이용한 표면실장기술의 적정 납량 결정 (Determination of Adequate Solder Volume using 3D Solder Joint Configuration in SMT)

  • 최동필;김성관;유중돈
    • Journal of Welding and Joining
    • /
    • 제14권2호
    • /
    • pp.71-78
    • /
    • 1996
  • In order to rpovide proper SMT design criteria in a systematic way, a mathematical formulation has been developed to predict the configuration of the solder fillet formed between the gullwing type lead and rectangular pad. Effects of SMT design parameters such as the solder volume and pad dimension on the solder profile are investigated using the FEM that calculates the 3D configuration by minimizing the energy due to surface tension and gravity in the equilibrium state. Design criteria of QFP and SOP are illustrated by plotting the acceptable range of the solder volume with respect to the length and width ratios of the pad and lead. The results show that the acceptable design range increases with increase in the pad length and width. The pad length has more significant effects on design criteria compared with the pad width, and Bond number can be utilized to predict the joint quality.

  • PDF

단면적 변화를 가지는 고온초전도체 전류도입선 해석 (Analysis of HTS Current Lead with Variable Area)

  • 문성수;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.22-25
    • /
    • 2000
  • To improve the performance of high temperature superconducting current leads, variable cross-sectional area is considered. The cross-sectional area is varied as a function of current density to fix the safety factor along lead length. New integration method is devised to find optimum cross-sectional area distribution. New design of current lead has low heat leak into cryostat and less material than constant cross-sectional area leads. Conduction cooled lead is considered. The developed method is applied to Bi2223 current leads sheathed Ag-Au alloy.

  • PDF

액체/전도냉각형 초전도 시스템에서 전류도입선의 열적 해석 (Thermal analysis of Current lead for Liquid/Conduction cooling on Superconducting system)

  • 권기범;김형진;정은수;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.178-181
    • /
    • 2003
  • Intermediate cooling for current lead is used of thermal link in conduction cooling and cooled of itself in liquid cooling because it is put in liquid. If a existing formula for cooling load and optimal diameter-length of current lead is applied, it generate some more cooling load. Therefore, variation of thermal link height and holding depth in liquid is considered. This result is used of reducing cooling load of current lead occupying most of superconducting system load and applying liquid/conduction cooling systems.

  • PDF

SOME APPLICATIONS OF EXTREMAL LENGTH TO ANALYTIC FUNCTIONS

  • CHANG BO-HYUN
    • 대한수학회논문집
    • /
    • 제21권1호
    • /
    • pp.135-143
    • /
    • 2006
  • We consider some applications of extremal length to the boundary behavior of analytic functions and derive theorems in connection with the conformal mappings. It shows us the usefulness of the method of extremal length. And we present some geometric applications of extremal length. The method of extremal length lead to simple proofs of theorems.

전류 도입선용 고온 초전도 선재 제작에 관한 연구 (A study on fabrication of Bi-2223 tape for current lead)

  • 임성우;박경국;한병성;하홍수;정대영;오상수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.835-837
    • /
    • 1998
  • Current lead plays the part of connector between ambient temperature and liquid helium superconducting magnet. Having zero resistance characteristic, it is expected that HTS has very low thermal conductivity and generate no joule heat when fabricated to current lead. In particular, among the HTS meterials, HTS tape has high Jc and Ag-sheath of tape plays the part of stabilizer, but it has too poor mechanical strength to be applied and when fabricated as long length tape, it has tendency to decline Jc seriously. In this study, we fabricated Bi-2223 multifilamentary tapes and then made current lead with stacking type using them. Through this work, we conclude that the defect of HTS long length tape is decreased by addition the number of stacking tape and that current lead is able to operate more stably by minimizing the gap of tapes.

  • PDF