• Title/Summary/Keyword: Large generator

Search Result 630, Processing Time 0.03 seconds

Healthy Assessment of Generator Stator Cores using EL-CID (ELectromagnetic Core Imperfection Detector) (EL-CID를 이용한 발전기 고정자 철심의 건전성 평가)

  • Kim, Byeong-Rae;Kim, Hee-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.356-362
    • /
    • 2009
  • The ELectromagnetic Core Imperfection Detector (EL-CID) test was performed on a small generator in the laboratory and a gas turbine generator in the field to assess the fault condition of generator stator core. Artificial defects with six different sizes were introduced in the small generator. The scan results on six defects show a very large increase in the magnitude of fault current compared to that obtained with a healthy core. After the stator core heats up, a thermal imaging camera was used to detect hot spot on the inner surface of the core for comparison. Several faults were found during inspection of the gas turbine generator with the EL-CID. It has been shown that the existence of a fault can be determined by monitoring the magnitude of fault current.

On-line partial discharge measurement techniques of hydro-generator windings (수력 발전기 권선에서의 운전중 부분방전 측정기법)

  • 황동하;김진봉;김용주;박명수;김택수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

A Study on the Generator Operation by the Electronic Consumption During the Summer in a Complex Building Cluster (복합시설의 하절기 전력사용량에 따른 발전기 가동현황 분석)

  • Kwon, Han-Sol;Kong, Dong-Seok;Kwak, Ro-Yeul;Huh, Jung-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.126-131
    • /
    • 2008
  • The large buildings in Korea usually use the generators to control the peak load of electronic consumption during the summer. It is necessary that these generators emit carbon dioxide, since they use gas or gasoline for their fuel. This study is to analyze the data of electronic consumption and operation of the generators at COEX, one of the representative complex building clusters in Korea, and to compare to the amount of carbon dioxide emitted per 1kWh from the domestic power plant by analogizing the frequency of using the generator during the summer and the amount of fuel consumption by the capacity of the generator and estimating the amount of carbon dioxide emitted from the generator.

  • PDF

An Optical Threshold Generator for the Stream Cipher Systems (스트림 암호 시스템을 위한 광 Threshold 발생기)

  • 한종욱;강창구;김대호;김은수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.11
    • /
    • pp.90-100
    • /
    • 1997
  • In this paper, we propose a new optical thresold generator as a key-stream genrator for stream cipher systems. The random key-bit stream is generated by a digital generator that is composed of LFSRs and nonlinear ligics. Digital implementatin of a key-stream generator requires large memory to implement programmable tapping points. This memory problem may be overcome easily by using the proposed optical system which has the proberty of 2D parallel processing.To implement hte threshold generator optically, we use conventional twisted nematic type SLMs (LCDs). This proposed system is based on the shadow casting technique for the AND operation between taps and sregister stages. It is also based on the proposed PMRS method for modulo 2 addition. The proposed PMRS method uses the property of light's polarization on LCD and can be implemented optically using one LCD and some mirrors. One of the major advantages of the proosed system is that there is no limitation of the number of the progarmmable tapping points. Therefore, the proposed system can be applied for the 2D encryption system which processes large amounts of data such as 2D images. We verify the proposed system with some simulation.

  • PDF

An Effective Priority Method Using Generator's Discrete Sensitivity Value for Large-scale Preventive Maintenance Scheduling (발전기 이산 민감도를 이용한 효율적인 우선순위법의 대규모 예방정비계획 문제에의 적용 연구)

  • Park, Jong-Bae;Jeong, Man-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.234-240
    • /
    • 1999
  • This paper presents a new approach for large-scale generator maintenance scheduling optimizations. The generator preventive maintenance scheduling problems are typical discrete dynamic n-dimensional vector optimization ones with several inequality constraints. The considered objective function to be minimized a subset of{{{{ { R}^{n } }}}} space is the variance (i.g., second-order momentum) of operating reserve margin to levelize risk or reliability during a year. By its nature of the objective function, the optimal solution can only be obtained by enumerating all combinatorial states of each variable, a task which leads to computational explosion in real-world maintenance scheduling problems. This paper proposes a new priority search mechanism based on each generator's discrete sensitivity value which was analytically developed in this study. Unlike the conventional capacity-based priority search, it can prevent the local optimal trap to some extents since it changes dynamically the search tree in each iteration. The proposed method have been applied to two test systems (i.g., one is a sample system with 10 generators and the other is a real-world lage scale power system with 280 generators), and the results anre compared with those of the conventional capacith-based search method and combinatorial optimization method to show the efficiency and effectiveness of the algorithm.

  • PDF

Study of Ship Wake Characteristics and the Propeller Cavitation by a Vortex Generator (와류생성기에 의한 선체반류 및 프로펠러 캐비테이션 특성 연구)

  • Seol, Hanshin;Ahn, Jong-Woo;Kim, Gun-Do;Park, Young-Ha;Kim, Sung-Pyo;Kim, Ki-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.1
    • /
    • pp.10-16
    • /
    • 2021
  • This paper systematically investigates and correlates pressure fluctuation and nominal wake characteristics according to the angle of the vortex generators by introducing the angle adjustment method of the Vortex Generator (VG). The vortex generators are installed at the port and starboard of a model ship. The vortex generator performance test is executed on a model ship installed in the Large Cavitation Tunnel (LCT) and the angle of VG is freely controlled by a servo motor. The systematic test results for the vortex generator show that the well-designed VG is an effective appendage for reducing the pressure fluctuation level and shows the direction of VG's angular design optimization.

Ultra fast Marx Generator of N2, SF6, N2-SF6 Mixture Gas based on Research Output Characteristics (초고속 Marx Generator의 N2, SF6, N2-SF6 혼합가스에 따른 출력 특성 연구)

  • Doo, Jin-Suk;Han, Seung-Moon;Huh, Chang-Su;Choi, Jin-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1850-1855
    • /
    • 2010
  • The application field of the pulse power is very wide. Recently, Pulse power technologies take a large place in several applications. Then, many civil and military applications proceed. Marx generator is widely used in high voltage applications. Marx generator is widely used in high voltage applications, such as eletromagnetic wave and power lasers. This paper, we described about the high voltage pulse generator. A compact size high voltage pulse generator with nanosecnd rise time has been fabricated and investigated experimentally. The marx generator has 2 stages. Each stage was constructed one charging capacitor, two electrodes and one charging resistor. A inductance structure is used in order to improve the switching performances fo the whole generator. The experiments of rise time in pure gas and mixtures of gases were described. We tested the Marx generator at different insulation gas. the results show that the dielectric strength of the $N_2-SF_6$ mixture was significantly increased compared with pure nitrogen gas. The experimental results show that the rise time characteristics of the Marx generator can be controlled through varying insulation gas.

Large-Scale Vortical Structure of Turbulent Separation Bubble Affected by Unsteady Wake (비정상 후류가 난류박리기포의 응집구조에 미치는 영향)

  • Jeon, Se-Jong;Seong, Hyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1218-1225
    • /
    • 2002
  • Large-scale vortical structure of a turbulent separation bubble affected by unsteady wake is essential to understand flow mechanisms in various fluid devices. A spoked-wheel type of wake generator provides unsteady wake, which modifies the turbulent separation bubble significantly by changing rotation directions and passing frequencies. A detailed mechanism of vortex shedding from the separation bubble with unsteady wake is analyzed by taking a conditional average with spatial box filtering, which spatially integrates measured signals at pre-determined wavelength. A convecting nature of the large-scale vortical structure is analyzed carefully. Spatial evolution of the large-scale vortical structure with frequency variance is also exemplified.

Automatic Quadrilateral Mesh Generation for Large Deformation Finite Element Analysis (대변형 유한요소해석을 위한 요소망 자동 생성기법)

  • 김동준;최호준;장동환;임중연;이호용;황병복
    • Transactions of Materials Processing
    • /
    • v.12 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • An automatic quadrilateral mesh generator for large deformation finite element analysis such as metal forming simulation was developed. The NURBS interpolation method is used for modeling arbitrary 2-D free surface. This mesh generation technique is the modified paving algorithm, which is an advancing front technique with element-by-element resolving method for paving boundary intersection problem. The mesh density for higher analysis accuracy and less analysis time can be easily controlled with high-density points, maximum and minimum element size. A couple of application to large deformation finite element analysis is given as an example, which shows versatility and applicability of the proposed approach and the developed mesh generator for large deformation finite element analysis.

Study on the Characteristic of System Frequency Decay In Case of Large Generator Unit Outage (전원탈락에 따른 계통주파수저하문제검토 제1보)

  • 송길영
    • 전기의세계
    • /
    • v.18 no.3
    • /
    • pp.7-14
    • /
    • 1969
  • According to the construction of Seoul Thermal #5 (250MW) unit, there will be prospected several new problems on the power system operation. This paper describes the characteristic of system frequency decay during severe emergencies which result in sudden outage of such large generator unit. It also studies the factors involved in applying under frequency relays to maintan an allowable frequency level and to prevent total area collapse by automatic load shedding program.

  • PDF