Sound Absorption Characteristics and Application Effect of PTFE Membrane Material (테프론 막 재료의 흡음특성 및 적용효과 연구)

  • Jeong, Jeong-Ho;Shon, Jang-Ryul;Kim, Jung-Joong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.4 s.121
    • /
    • pp.342-349
    • /
    • 2007
  • Following the 2002 World-Cup held in Korea, studies have been actively conducted on plans to utilize all-weather stadiums of fine figures, where large-scale spaces are available for various utilizations. In Japan, dome-type stadiums have been built and are utilizing across the whole nation not only for sports events but also variety of other large-scale events. PTFE(poly tetra fluoro ethylene) is one of the membrane material mainly used for the outer ceiling surface of membrane structures. However, there has not been enough research on the acoustical properties of PTFE membrane material which has been widely used in the multi-purpose stadiums. In this study, air permeability values and sound absorption coefficient of PTFE membrane materials were measured and evaluated in the gymnasium. From the results of measurements of sound absorption coefficient and air permeability of inner membrane materials, it was found that the sound absorption coefficient was good in the air permeability range of $5{\sim}15\;cc/cm^2/s$. Also the relation ship between air permeability and sound absorption coefficient was very high and the sound absorption coefficient was the highest in the range of $6{\sim}9\;cc/cm^2/s$. Secondly, an analysis on the measurements sound absorption characteristics of inner membrane material reveals that the overall sound absorption coefficient was stabilized(higher than 0.5 throughout the whole frequency bands) when the air space behind the membrane material was deeper than 600 mm. When PTFE sound absorptive membrane material was installed in the ceiling of gymnasium, it was confirmed that sound absorptive membrane material can reduce reverberation and increase speech intelligibility in the gymnasium.

The Study about Architectural Plan and Practical use of Multipurpose Room of School Facilities(Auditorium, Gymnasium) (학교시설의 다목적실(강당, 체육관)에 대한 건축계획)

  • Shin, Woun-Shik;Han, Kyu-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.2
    • /
    • pp.5-16
    • /
    • 2004
  • Auditorium and gymnasium are utilized in rare cases compared to the large spacial size. From Monday to Saturday, the use of them is extremely rare, which shows the serious example of economical inefficiency of architectural space. To solve these problems, inquiries from the various viewpoints will be necessary. Architecture-philosophically, how can space and time considered sufficiently? How is the structure related to phase. The object of this study is to arrange newly economical efficiency of space and time which are treated slightingly as they mentioned above and the plan about the design of the architectural space and multipurpose room.

A Study on the Application of Fire Protection Facilities in Large Enclosure Gymnasium (대규모 실내경기장의 소방방재설비 적용현황 분석)

  • Choi, Dong-Ho;Kim, Choon-Dong;Yang, Jeong-Hoon;Cho, Young-Hum
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.135-145
    • /
    • 2010
  • The objective of this study is to draw basic data for the application of the fire protection planning for the future plan large enclosure buildings in Korea through an analysis of its characteristics by case studies of the domestic and foreign large scale gymnasiums. In this study, domestic building codes for the fire protection are investigated and fire detection systems, fire extinguishing systems, smoke control systems and evacuation systems of three large scale gymnasiums located at Korea and eight foreign countries are compared and analyzed. The results of this study show that infrared light fire detection system and flame detector for spacial characteristics are potentially used in fire protection systems of large scale gymnasiums: dry type sprinkler and sprinkler water gun are adopted in fire detection system; and smoke accumulation system is widely utilized in smoke control system.

  • PDF

Force monitoring of Galfan cables in a long-span cable-truss string-support system based on the magnetic flux method

  • Yuxin Zhang;Xiang Tian;Juwei Xia;Hexin Zhang
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.3
    • /
    • pp.261-281
    • /
    • 2023
  • Magnetic flux sensors are commonly used in monitoring the cable force, but the application of the sensors in large diameter non-closed Galfan cables, as those adopted in Yueqing Gymnasium which is located in Yueqing City, Zhejiang Province, China and is the largest span hybrid space structure in the world, is seldom done in engineering. Based on the construction of Yueqing Gymnasium, this paper studies the cable tension monitoring using the magnetic flux method across two stages, namely, the pre-calibration stage before the cable leaves the rigging factory and the field tension formation stage of the cable system. In the pre-calibration stage in the cable factory, a series of 1:1 full-scale comparative tests were carried out to study the feasibility and relability of this kind of monitoring method, and the influence on the monitoring results of charging and discharging voltage, sensor location, cable diameter and fitting method were also studied. Some meaningful conclusions were obtained. On this basis, the real-time cable tension monitoring system of the structure based on the magnetic flux method is established. During the construction process, the monitoring results of the cables are in good agreement with the data of the on-site pressure gauge.The work of this paper will provide a useful reference for cable force monitoring in the construction process of long-span spatial structures.

A Fundamental Study of Performance Based Seismic Design on the Large Span Structures: The Characteristics of Elasto-Plastic Earthquake Responses of a Steel Frame with Membrane Roof (공간구조물의 성능기초 내진설계에 관한 기초연구: 강구조 골조막 구조의 탄소성 지진응답특성)

  • Nakazawa, Shoji;Cheong, Myung-Chae;Kato, Shi;Yoshino, Tatsuya;Oda, Kenshi
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.35-44
    • /
    • 2007
  • The characteristics of elasto-plastic responses of a gymnasium building which is a steel braced frame with membrane roof is discussed as a basic research on the performance based seismic design of large span structures, in this paper. Under the strong earthquake motions, the formation of plastic hinges on braces attached by the bottom frame make reduce down the stresses and displacements of upper structures, and vertical acceleration of the membrane is tend to increase but maximum response of strain and corresponding stresses are tend to be reduced.

  • PDF

Lightings Arrangement Method of the Small Gymnasiums (소형 옥내 운동장의 조명기구 배치방식)

  • Kim, Tae-Hoon;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.1-6
    • /
    • 2014
  • In KSC 3706, the gymnasiums are classified according to their size(small, medium, large) and there are two kinds of illumination arrangement method for them such as Side and Distributed. The characteristic of the distributed illumination arrangement method is excellent in uniformity and the characteristic of the side illumination arrangement method is excellent in glare. but illuminations were so diverse that features are not always applicable. So in this paper, in this paper, We analyzed characteristic of distributed illumination arrangement method and side illumination arrangement method using nine illumination.

A Study on the Composition Features of Educational Facilities for Timber Structure in Japan with respect to Structural Planning (구조계획 측면에서 본 일본 목구조 교육시설의 구성특성 분석)

  • Lee, Juna;Shin, Eun-Mi
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.6
    • /
    • pp.11-20
    • /
    • 2018
  • In order to figure out the usability of various timber structures in the educational facility, the recent timber structure examples published in the Japanese architectural magazine, 'ShinKenchiku' over the past five years were surveyed. As the results, timber structures were presented in many cases of nursery schools and kindergartens overwhelmingly, and they also used in various school buildings, university facilities, and the roof structure of the school's gymnasium, with intention of having the differentiated design and space features. The examples show that span 6 to 10m is generally used with flexure structure system and flexure+compression structure system added the strut as compression members. In addition concerning stability, it was founded that the struts have an stability effect in the flexure+compression structure system, and flexure structure system examples using semi-rigid joints have open spaces liberally in two-way direction for about 9m span. For large spaces structures with span of 15~20m or more, the various structural system such as suspension structure, truss, flexure+compression, etc. was designed to overcome the material limitations of timbers and to make an design effect in structure system.

The Theory and Application of Health Promotion Program at Work Sites (산업장 건강증진 사업의 이론과 실제)

  • 정영일;이현경
    • Korean Journal of Health Education and Promotion
    • /
    • v.16 no.1
    • /
    • pp.203-232
    • /
    • 1999
  • This study reviewed the, reference of health promotion program and investigated the status of health promotion program at work sites in U.S.A. Good health promotion program is essential for both employees and employers to reduce morbidity rate, to promote productivity and to enhance quality of life and so on. Health promotion aimed at modifying unhealthy life-styles by building awareness, knowledge, skills, and interpersonal support. And health promotion cycle is resemblance to the plan-do-check-act. The major contents of this study are briefed following as : 1) Links between life-style, environment, and health 2) Effect of work sites health promotion effort 3) Prevalence and contents of work site health promotion programs 4) Health promotion process 5) Program framework and structure 6) Stages in the health promotion cycle 7) Approaches for modifying organizational stressors In addition this, the survey was conducted to aim diagnosing the status of health promotion p개gram in work sites in Korea. The main finding-outs are summarized as follows: 1) In 4 large size work sites, there are working with 1 doctor in all work sites, 1 nurse per 3,000 employees and other health related professionals. They have clinic office(4 work sites), gymnasium(2 work sites), and other many facilities like physical therapy center. And only one company have a wellness clinic center. All employees use to exercise health gymnastics in terms of 5 minutes regularly 2 times in a day. 2) In 4 middle size work sites, there are no doctor, 1 nurse and 1 nutritionist in all work sites. They have also clinic, physical therapy center(1 work site), and all employees exercise health gymnastics regularly 2 times in a day too.

  • PDF

A Study on the Space Composition of the Educational Cultural Center for Students (학생교육문화회관의 공간구성에 관한 연구)

  • Jeong, Gwan-Yeong;Lim, Jang-Lyul;Kim, Yong-Hwan
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.12 no.5
    • /
    • pp.25-34
    • /
    • 2005
  • The Educational Cultural Center for Students is a new mixed-cultural space which made around 1997 for students' education of humanism and talent with the 7th revision of educational course. This Educational Cultural Center for Students is different to the existing one because the subject of the culture is students who make creation and performance by themselves while the former ones were for seeing, hearing and feeling things. There are seven Educational Cultural Center for Students all over the country and will be built more in the future. Comparing to the former Educational Cultural Centers for Students, functional rooms in the Educational Cultural Centers for Students are an outdoor performance room, a large performance room, a small performance room of performance facility, a gallery of display facility, a gymnasium, a swimming pool, a fitness room, a table-tennis room of physical facility, a library and a reading room of a book facility, and a group room, a computer room, a singing room, a billiard room, an art room, a musical room, a dancing room, a manner room, a playing room, a cultural lecture room and a seminar room of a interest-activity facility. The result of analyzing the usage frequency is that a performance room has the highest frequency and a display room, a musical room, a music appreciation room and a physical room follow the frequency order. But this frequency does not fit for all area. By place and social situations, the frequency and space organization may be changed.

A Study on the Operations of School Safety Experience Education Space (초등학교 안전체험교육 공간 운영 방안에 관한 연구)

  • Lee, Geun-Im;Lee, Yong-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.3
    • /
    • pp.61-68
    • /
    • 2017
  • The purpose of this study is to suggest the necessary measures for the school safety experience education space to provide the elementary school students with the ability to provide safety education through experiences routinely and repeatedly. For this purpose, we investigated the conditions of safety experience in Jeollabuk-do and the case of other cities as a factor for operating the school safety experience educational space. In order to clarify the appropriateness of this, a questionnaire was conducted for the teachers in the local area. As a result of the analysis, it was found that the use of two classrooms in the place and the scale in the operation of the school safety experiential education space should be sought in various places such as hall, multipurpose room, and gymnasium according to the school condition. Experiential areas should be operated by elementary school students customized, but specialized facilities or large scale should be used for professional safety experience facilities. For efficient operation, the base school wanted to be located in a place where accessibility of other school students was easy, and that a school with sufficient space would be selected.