• Title/Summary/Keyword: Large Balloon

Search Result 40, Processing Time 0.029 seconds

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

The Study on the applied Balloon Art in Interior and Exterior Space (풍선아트의 실내.외 공간 적용에 관한 연구)

  • Choi, Ok-Ju;Kim, Nam-Hyo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.169-172
    • /
    • 2008
  • Nationally large scale of festival is common in these days, the space for a space be party-able such as an event space or an performance space is more necessary. Accordingly applied the balloon art which utilizes a balloon material, to interior and exterior space design can maximize space design for the nonce and renovate space with flexible materials which is the balloon art. This research provides the balloon art is able to be a new research field in interior and exterior design study with three types of way to apply the balloon art to interior and exterior design. First type is an applied interior design with the balloon art, second type is an applied party space design with the balloon art, and third type is practical examples of applied interior design with mixing materials of the balloon and another materials.

  • PDF

Cost-Effective High-Altitude Scientific Balloon Development and its Flight Test (비용효율적인 고고도 과학기구 개발 및 비행시험)

  • Kang, Jungpyo;Shim, Gyujin;Kim, Hweeho;Lee, Yongseon;Yee, Kwanjung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.345-358
    • /
    • 2018
  • The high altitude scientific balloon has been used for decades in advanced aerospace countries such as United States, France, and Japan to carry out various research objectives. Since the initial cost for development and operation is enormous, it has been conducted by national research institutes. Recently, the advent of open source software/hardware ecosystems with low-cost yet high-performance have lowered barriers to enter into scientific balloon research and development. In this study, a zero pressure balloon prototype was designed considering the cost, usability, compatibility, and development period by using commercial off the shelf (COTS) items. In addition, the flight operation experience was accumulated through eight times of the flight tests, and operational reliability of the balloon system was verified. Finally, the foundation for the operation of the large zero pressure balloon was established.

Effectiveness of Anchoring with Balloon Guide Catheter and Stent Retriever in Difficult Mechanical Thrombectomy for Large Vessel Occlusion

  • Yi, Ho Jun;Kim, Bum-Tae;Shin, Dong-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.514-522
    • /
    • 2022
  • Objective : A distal navigation of a large bore aspiration catheter during mechanical thrombectomy (MT) is important. However, delivering a large bore aspiration catheter is difficult to a tortuous or atherosclerotic artery. We report the experience of anchoring with balloon guide catheter (BGC) and stent retriever to facilitate the passage of an aspiration catheter in MT. Methods : When navigating an aspiration catheter failed with a conventional co-axial microcatheter delivery, an anchoring technique was used. Two types of anchoring technique were applied to facilitate distal navigation of a large bore aspiration catheter during MT. First, a passage of aspiration catheter was attempted with a proximal BGC anchoring technique. If this technique also failed, another anchoring technique with distal stent retriever was tried. Consecutive patients who underwent MT with an anchoring technique were identified. Details of procedure, radiologic outcomes, and safety variables were evaluated. Results : A total of 67 patients underwent MT with an anchoring technique. Initial trial of aspiration catheter passage with proximal BGC anchoring technique was successful for 35 patients (52.2%) and the second trial with distal stent retriever anchoring was successful for 32 patients (47.8%). Overall, navigation of a large bore aspiration catheter was successful for all patients (100%) without any procedure related complications. Conclusion : Our study showed the usefulness of anchoring technique with proximal BGC and distal stent retriever during MT, especially in those with an unfavorable anatomical structure. This technique could be an alternative option for delivering an of aspiration catheter to a distal location.

Endovascular Graft-Stent Placement for Treatment of Traumatic Carotid Cavernous Fistulas

  • Choi, Beom-Jin;Lee, Tae-Hong;Kim, Chang-Won;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.572-576
    • /
    • 2009
  • Detachable balloon-based endovascular fistula occlusion is a widely accepted treatment for traumatic carotid cavernous fistulas (CCF). However, more recently coils have been used to obliterate the lesion, especially in case detachable balloon is not available. We failed balloon-assisted coil embolization for CCF because of large fistulas and herniation of coil loops into the parent artery. The authors describe our experiences of balloon-expandable graft-stents to treat CCF, and place emphasis on arterial wall reconstruction. Three traumatic CCF patients were treated using a graft-stent with/without coils, and underwent angiographic follow-up to evaluate the patency of the internal carotid artery (ICA). In all cases, symptoms related to CCF regressed after stent deployment and did not recur during follow-up. Follow-up angiography revealed good patency of the ICA in all patients. Graft-stents should be considered as an alternative means of treating CCF and preserving the parent artery by arterial wall reconstruction especially in patients with a fistula that cannot be successfully occluded with detachable balloons or coils.

Intervention with Balloon Valvuloplasty followed by Patent Ductus Arteriosus Stent in a Patient with Pulmonary Atresia with Intact Ventricular Septum (풍선판막성형술과 동맥관 스텐트를 이용하여 치료한 심실중격결손을 동반하지 않은 폐동맥 폐쇄 1례)

  • Lim, Han Hyuk;Kim, Young Deuk;Lee, Jae Hwan;Chang, Mea Young;Kil, Hong Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.11
    • /
    • pp.1256-1256
    • /
    • 2005
  • Pulmonary atresia with intact ventricular septum (PAIVS) is rare, less than 1% of congenital heart disease. It needs a therapeutic approach according to its individual morphologic feature. Surgical treatment of valvotomy and modified Blalock-Taussig shunt or non-surgical interventional catheter balloon valvuloplasty can be used for mild to moderate hypoplasia of right ventricle. Fontan operation can be considered for less optimum morphological substrate of two ventricular repair. A 3-day-old male neonate was admitted with cyanosis and cardiac murmur. On echocardiogram, he had membranous pulmonary atresia with intact ventricular septum, normal sized tripartite right ventricle, large atrial septal defect with right-to-left shunt, small sized patent ductus arteriosus, and moderate tricuspid regurgitation. He was treated with intravenous continuous infusion of prostaglandin $E_1$ ($PGE_1$) at once. On the third day of hospitalization, Balloon valvuloplasty was performed. After insertion of patent ductus arteriosus stent on the tenth day, $PGE_1$ infusion was discontinued. On the fifteenth day, he was discharged. Now, he is 9 months old and has nearly normal cardiac structure and function with 97% of percutaneous oxygen saturation.

Salivary Secretion Volume Related Ruminal Distension and Suppression of Dry Forage Intake in Large-type Goats

  • Thang, Tran Van;Sunagawa, Katsunori;Nagamine, Itsuki;Ogura, Go
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.8
    • /
    • pp.1100-1111
    • /
    • 2011
  • Two experiments under sham feeding conditions were conducted to determine whether or not ruminal distension brought about by feed boluses entering the rumen is a factor in the marked suppression of feed intake after 40 min of feeding. In experiment 1, a comparison was made between the intraruminal insertion of a water filled balloon (RIB) treatment and normal control (non-insertion of a balloon, NIB). In experiment 2, saliva lost due to sham feeding conditions was replenished via an intraruminal infusion of iso-osmotic artificial saliva. A comparison of dry forage intake was then conducted between the intraruminal replenishment of iso-osmotic artificial saliva and insertion of a balloon (RRIAS-RIB) treatment, and the intraruminal replenishment of iso-osmotic artificial saliva and non-insertion of a balloon (RRIAS-NIB) control. In experiment 1, eating rates in the RIB treatment 30 min after the commencement of feeding tended to be lower than those in the NIB control. In comparison with the NIB control, cumulative dry forage intake in the RIB treatment was 29.7% less (p<0.05) upon conclusion of the 2 h feeding period. The secreted saliva weight in the NIB control and the RIB treatment during the 2 h feeding period was 53.2% and 60.9% total weight of the boluses, respectively. In experiment 2, eating rates in the RRIAS-RIB treatment 30 min after the commencement of feeding was significantly lower (p<0.05) than those in the RRIAS-NIB control. Cumulative dry forage intake in the RRIAS-RIB treatment was a significant 45.5% less (p<0.05) compared with that in the RRIAS-NIB control upon conclusion of the 2 h feeding period. The secreted saliva weight in the RRIAS-NIB control and the RRIAS-RIB treatment during the 2 h feeding period was 54.1% and 64.2% total weight of the boluses, respectively. The level of decrease in dry forage intake in the RRIAS-RIB treatment of experiment 2 was larger than that in the RIB treatment of experiment 1. In the present experiments, due to the sham feeding conditions, the increases in osmolality of ruminal fluid and plasma, and a decrease in ruminal fluid pH which are normally associated with feeding were not observed. The results indicate that the marked decrease in feed intake observed in the second hour of the 2 h feeding period is related to ruminal distension caused by the feed consumed and the copious amount of saliva secreted during dry forage feeding.

Rectal Balloon for the Immobilization of the Prostate Internal Motion (전립선암의 방사선치료 시 직장풍선의 유용성 평가)

  • Lee Sang-Kyu;Beak Jong-Geal;Kim Joo-Ho;Jeon Byong-Chul;Cho Jeong-Hee;Kim Dong-Wook;Na Soo-Kyong;Song Tae-Soo;Cho Jae-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.113-124
    • /
    • 2005
  • Purpose : The using of endo-rectal balloon has proposed as optimal method that minimized the motion of prostate and the dose of rectum wall volume for treated prostate cancer patients, so we make the customized rectal balloon device. In this study, we analyzed the efficiency of the Self-customized rectal balloon in the aspects of its reproducibility. Materials and Methods : In 5 patients, for treatment planning, each patient was acquired CT slice images in state of with and without rectal balloon. Also they had CT scanning samely repeated third times in during radiation treatment (IMRT). In each case, we analyzed the deviation of rectal ballon position and verified the isodose distribution of rectum wall at closed prostate. Results : Using the rectal balloon, we minimized the planning target volume (PTV) by decreased the internal motion of prostate and overcome the dose limit of radiation therapy in prostate cancer by increased the gap between the rectum wall and high dose region. Conclusion : The using of rectal balloon, although, was reluctant to treat by patients. View a point of immobilization of prostate internal motion and dose escalation of GTV (gross tumor volume), its using consider large efficients for treated prostate cancer patients.

  • PDF

The Application of Gassed Bulk Emulsion to Quarry Blasting in Limestone Mine (석회석 광산 채석발파에서 Gassed Bulk Emulsion의 적용)

  • Min, Hyung-Dong;Jeong, Min-Su;Park, Yun-Seok;Lee, Eung-So;Lee, Won-Wook
    • Explosives and Blasting
    • /
    • v.25 no.2
    • /
    • pp.61-70
    • /
    • 2007
  • Korean large limestone mines started to employ bulk emulsion explosives to improve the productivity in early 2000s. As the application of the bulk emulsion explosives became common in the mid 2000s, the bulk emulsion application increases overall performance but it tends to decrease the moving and heaving because it lacks in gas volume and heat energy. Therefore, the chemical gassing technique was introduced to improve the blasting efficiency of the existing bulk emulsion explosives. The chemical gassing is a technique to replacing GMB(Glass Micro Balloon), which is used for a sensitizer, with gassing agent to chemically sensitize it. This paper introduces the case of successful application of chemical gassing in a Korean large limestone mine. We also compared and evaluated the blast and work efficiency between bulk emulsion GMB & gassing agent (chemical gassing). The results indicate that the replacement of GMB with gassing agent improved fragmentation in the upper part and toe of a bench as well as moving efficiency of the material.

Comparative Study of Bifurcation Behavior of Rubber in Accordance with the Constitutive Equations (구성방정식에 따른 고무 분기점 거동 비교 연구)

  • Park, Moon-Shik;Song, Seung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.731-742
    • /
    • 2010
  • Modeling of rubber for design or analysis often requires confusing or complex work because there are a large number of constitutive models to be considered. Some models have few material constants, while others have many. Researchers have to prepare and fit extensive experimental data with caution and discretion. In this paper, we first compared some typical rubber models in which deformation was carried out by stretching up to around eight times the original size. We conclude that continuum-based models and chain molecular models can be used in the study of the small deformation in most engineering applications, but chain molecular models are preferred in the study of the large deformations in most biomaterial applications. As discrimination problems, Treloar's patch and cylindrical balloon stick are tested theoretically and numerically for studying bifurcation. In the case of Treloar's patch, by using the Kearsley's equation, we show that bifurcation exists for continuum-based models but not for chain molecular models. Both models show bifurcation in the cylindrical balloon stick. Therefore, in the analysis of the bifurcation of rubber showed that its existence also depends on the constitutive model selected.