Acknowledgement
This study was supported by the National Research Foundation of Korea (NRF-2021R1G1A1094797) and the Soonchunhyang University Research Fund.
References
- Amarenco P, Bogousslavsky J, Caplan LR, Donnan GA, Hennerici MG : Classification of stroke subtypes. Cerebrovasc Dis 27 : 493-501, 2009 https://doi.org/10.1159/000210432
- Crowley RW, Abla AA, Ducruet AF, McDougall CG, Albuquerque FC : Novel application of a balloon-anchoring technique for the realignment of a prolapsed pipeline embolization device: a technical report. J Neurointerv Surg 6 : 439-444, 2014 https://doi.org/10.1136/neurintsurg-2013-010806
- Fargen KM, Velat GJ, Lawson MF, Hoh BL, Mocco J : The stent anchor technique for distal access through a large or giant aneurysm. J Neurointerv Surg 5 : e24, 2013 https://doi.org/10.1136/neurintsurg-2012-010276
- Goto S, Ohshima T, Ishikawa K, Yamamoto T, Shimato S, Nishizawa T, et al. : A stent-retrieving into an aspiration catheter with proximal balloon (ASAP) technique: a technique of mechanical thrombectomy. World Neurosurg 109 : e468-e475, 2018 https://doi.org/10.1016/j.wneu.2017.10.004
- Goyal M, Menon BK, Van Zwam WH, Dippel DW, Mitchell PJ, Demchuk AM, et al. : Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomised trials. Lancet 23 : 387, 2016
- Hacke W, Kaste M, Bluhmki E, Brozman M, Davalos A, Guidetti D, et al. : Thrombolysis with alteplase 3 to 4.5 hours after acute ischemic stroke. N Engl J Med 359 : 1317-1329, 2008 https://doi.org/10.1056/NEJMoa0804656
- Hopf-Jensen S, Preiss M, Marques L, Lehrke S, Schattschneider J, Stolze H, et al. : Impact and effectiveness of dual aspiration technique in stent-assisted mechanical thrombectomy: recent improvements in acute stroke management. Cardiovasc Intervent Radiol 39 : 1620-1628, 2016 https://doi.org/10.1007/s00270-016-1404-4
- Kang DH, Park J : Endovascular stroke therapy focused on stent retriever thrombectomy and direct clot aspiration: historical review and modern application. J Korean Neurosurg Soc 60 : 335-347, 2017 https://doi.org/10.3340/jkns.2016.0809.005
- Kim SH, Lee H, Kim SB, Kim ST, Baek JW, Heo YJ, et al. : Hybrid mechanical thrombectomy for acute ischemic stroke using an intermediate aspiration catheter and Trevo stent simultaneously. J Clin Neurosci 76 : 9-14, 2020 https://doi.org/10.1016/j.jocn.2020.04.079
- Lapergue B, Blanc R, Guedin P, Decroix JP, Labreuche J, Preda C, et al. : A direct aspiration, first pass technique (ADAPT) versus stent retrievers for acute stroke therapy: an observational comparative study. AJNR Am J Neuroradiol 37 : 1860-1865, 2016 https://doi.org/10.3174/ajnr.A4840
- Lee DH, Sung JH, Kim SU, Yi HJ, Hong JT, Lee SW : Effective use of balloon guide catheters in reducing incidence of mechanical thrombectomy related distal embolization. Acta Neurochir (Wien) 159 : 1671-1677, 2017 https://doi.org/10.1007/s00701-017-3256-3
- Li ZS, Zhou TF, Li Q, Guan M, Liu H, Zhu LF, et al. : Endovascular management of intracranial atherosclerosis-related large vessel occlusion with the a direct aspiration first-pass thrombectomy compared with solumbra technique. Front Neurol 12 : 643633, 2021 https://doi.org/10.3389/fneur.2021.643633
- Lin CM, Wu YM, Chang CH, Chen CC, Wang AY : The ANTRACK technique: employing a compliant balloon or stent retriever to advance a large-bore catheter to an occlusion during thrombectomy procedures in acute stroke patients. Oper Neurosurg (Hagerstown) 16 : 692-699, 2019 https://doi.org/10.1093/ons/opy202
- Mascitelli JR, Pain M, Zarzour HK, Baxter P, Ghatan S, Mocco J : Sinus thrombectomy for purulent cerebral venous sinus thrombosis utilizing a novel combination of the trevo stent retriever and the penumbra ACE aspiration catheter: the stent anchor with mobile aspiration technique. J Neurointerv Surg 8 : e24, 2016 https://doi.org/10.1136/neurintsurg-2015-011782.rep
- Maus V, Behme D, Kabbasch C, Borggrefe J, Tsogkas I, Nikoubashman O, et al. : Maximizing first-pass complete reperfusion with SAVE. Clin Neuroradiol 28 : 327-338, 2018 https://doi.org/10.1007/s00062-017-0566-z
- Munich SA, Vakharia K, Levy EI : Overview of mechanical thrombectomy techniques. Neurosurgery 85(Suppl 1) : S60-S67, 2019 https://doi.org/10.1093/neuros/nyz071
- Nguyen TN, Malisch T, Castonguay AC, Gupta R, Sun CH, Martin CO, et al. : Balloon guide catheter improves revascularization and clinical outcomes with the solitaire device: analysis of the north american solitaire acute stroke registry. Stroke 45 : 141-145, 2014 https://doi.org/10.1161/strokeaha.113.002407
- Nikoubashman O, Nikoubashman A, Busen M, Wiesmann M : Necessary catheter diameters for mechanical thrombectomy with ADAPT. AJNR Am J Neuroradiol 38 : 2277-2281, 2017 https://doi.org/10.3174/ajnr.A5401
- Oh JS, Yoon SM, Shim JJ, Doh JW, Bae HG, Lee KS : Efficacy of balloon-guiding catheter for mechanical thrombectomy in patients with anterior circulation ischemic stroke. J Korean Neurosurg Soc 60 : 155-164, 2017 https://doi.org/10.3340/jkns.2016.0809.003
- Ohshima T, Miyachi S : A novel technique for mitigation of the ledge effect caused by the use of a large-lumen catheter during neurointervention: beanstalk method. Asian J Neurosurg 15 : 753-755, 2020 https://doi.org/10.4103/ajns.ajns_238_20
- Romano DG, Frauenfelder G, Casseri T, Piano M, Vinci S, Comai A, et al. : Efficacy of ADAPT with large-bore reperfusion catheter in anterior circulation acute ischemic stroke: a multicentric italian experience. Radiol Med 125 : 57-65, 2020 https://doi.org/10.1007/s11547-019-01069-x
- Sharashidze V, Nogueira RG, Al-Bayati AR, Grossberg JA, Haussen DC : Balloon anchoring technique for thrombectomy in hostile craniocervical arterial anatomy. J Neurointerv Surg 12 : 763-767, 2020 https://doi.org/10.1136/neurintsurg-2019-015347
- Singh J, Wolfe SQ, Janjua RM, Hedayat H, Burnette C : Anchor technique: use of stent retrievers as an anchor to advance thrombectomy catheters in internal carotid artery occlusions. Interv Neuroradiol 21 : 707-709, 2015 https://doi.org/10.1177/1591019915609170
- Snyder KV, Natarajan SK, Hauck EF, Mocco J, Siddiqui AH, Hopkins LN, et al. : The balloon anchor technique: a novel technique for distal access through a giant aneurysm. J Neurointerv Surg 2 : 363-367, 2010 https://doi.org/10.1136/jnis.2009.002006
- Takahira K, Kataoka T, Ogino T, Endo H, Nakamura H : Efficacy of a coaxial system with a compliant balloon catheter for navigation of the penumbra reperfusion catheter in tortuous arteries: technique and case experience. J Neurosurg 126 : 1334-1338, 2017 https://doi.org/10.3171/2016.3.JNS152790
- Turk AS, Frei D, Fiorella D, Mocco J, Baxter B, Siddiqui A, et al. : ADAPT FAST study: a direct aspiration first pass technique for acute stroke thrombectomy. J Neurointerv Surg 6 : 260-264, 2014 https://doi.org/10.1136/neurintsurg-2014-011125
- Turk AS, Frei D, Fiorella D, Mocco J, Baxter B, Siddiqui A, et al. : ADAPT FAST study: a direct aspiration first pass technique for acute stroke thrombectomy. J Neurointerv Surg 10(Suppl 1) : i4-i7, 2018 https://doi.org/10.1136/neurintsurg-2014-011125.rep
- Uysal E, Caliskan C, Caymaz I, Orken DN, Basak M : Stenting of vertebral artery origin with the buddy wire technique in tortuous subclavian artery. A case report. Interv Neuroradiol 16 : 175-178, 2010 https://doi.org/10.1177/159101991001600209
- Vakharia K, Munich SA, Tso MK, Waqas M, Levy EI : Stent anchor technique to reduce microcatheter loop for stent-assisted coiling of anterior communicating artery aneurysm. Neurosurg Focus 46(Suppl 1) : V8, 2019
- Woo HG, Sunwoo L, Jung C, Kim BJ, Han MK, Bae HJ, et al. : Feasibility of permanent stenting with solitaire FR as a rescue treatment for the reperfusion of acute intracranial artery occlusion. AJNR Am J Neuroradiol 39 : 331-336, 2018 https://doi.org/10.3174/ajnr.A5477
- Yi HJ, Lee DH, Sung JH : Clinical usefulness of waiting after stent deployment in mechanical thrombectomy: effect of the clot integration. World Neurosurg 119 : e87-e93, 2018 https://doi.org/10.1016/j.wneu.2018.07.040
- Yi HJ, Sung JH, Lee DH : Preliminary experience of neuroform atlas stenting as a rescue treatment after failure of mechanical thrombectomy caused by residual intracranial atherosclerotic stenosis. J Korean Neurosurg Soc 64 : 198-206, 2021 https://doi.org/10.3340/jkns.2020.0146
- Yi HJ, Sung JH, Lee DH, Song SY : Effectiveness and technical considerations of solitaire platinum 4×40 mm stent retriever in mechanical thrombectomy with solumbra technique. J Korean Neurosurg Soc 64 : 30-38, 2021 https://doi.org/10.3340/jkns.2020.0046
- Yi HJ, Sung JH, Lee MH, Lee DH : Experience of the new flowgate2 device as a balloon guide catheter for ischemic stroke intervention. World Neurosurg 126 : e736-e742, 2019 https://doi.org/10.1016/j.wneu.2019.02.140
- Yoo AJ, Frei D, Tateshima S, Turk AS, Hui FK, Brook AL, et al. : The penumbra stroke system: a technical review. J Neurointerv Surg 4 : 199-205, 2012 https://doi.org/10.1136/neurintsurg-2011-010080