• Title/Summary/Keyword: LOAD CELL

Search Result 1,188, Processing Time 0.033 seconds

Characteristics of Settlement and Bearing Capacity of Soft Ground Improved by Granular Pile (Granular Pile에 의해 개량된 연약지반의 지지력 및 침하특성)

  • 천병식;여유현
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.289-294
    • /
    • 2002
  • Sand Compaction Pile (SCP) method, which uses sand material, is frequently used in Korea. However, the use of sand for SCP faces environmental and economical problems with the shortage of its resources. Therefore, it is necessary to substitute other materials for compaction piles. One of the alternatives is using gravel in lieu of sand. Granular Pile, constituted with sand and crushed-stone, is one of the methods to improve soft clay and loose sandy ground. In this study, modeled pile load tests are performed in test cell. The observations are made on the consolidation and the variation of water table of three different grounds, original, sand pile installed, and granular pile installed ground. In addition, engineering characteristics such as bearing capacity, settlement and drainage are investigated. The test results show that Gravel Compaction Pile (GCP) is more efficient for increasing bearing capacity and reducing settlement than SCP and had similar pore water pressure dissipation to sand. Therefore, the results show that GCP can be a good substitution for SCP.

  • PDF

Efficient Data Transmission Scheme for Underwater Wireless Sensor Networks (수중 센서 네트워크를 위한 효율적인 데이터 전송 기법)

  • Park, Hyun-Hoon;Park, Jin-Ho;Lee, Jong-Geun;Kim, Sung-Un
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.43-44
    • /
    • 2007
  • The Underwater Wireless Sensor Network (UWSN) consists of sensor nodes equipped with a small battery of limited energy resource. Hence, the energy efficiency is a key design issue that needs to be addressed in order to improve the lifetime of the network. In this paper, we use a hexagon tessellation with and ideal cell size to deploy the underwater sensor nodes for the UWSN and propose an enhanced hybrid transmission method that considers the load balancing once the data transmission occurs.

  • PDF

Thrust - Performance Test of Ethylene-Oxygen Single-Tube Pulse Detonation Rocket

  • Hirano, Masao;Kasahara, Jiro;Matsuo, Akiko;Endo, Takuma;Murakami, Masahide
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.205-210
    • /
    • 2004
  • The pulse detonation engine (PDE) has recently expected as a new aerospace propulsion system. The PDE system has high thermal efficiency because of its constant-volume combustion and its simple tube structure. We measured thrust of single-tube pulse detonation rocket (PDR) by two methods using the PDR-Engineering Model (full scale model) for ground testing. The first involved measuring the displacement of the PDR-EM by laser displacement meter, and the second involved measuring the time-averaged thrust by combining a load cell and a spring-damper system. From these two measurements, we obtained 130.1 N of time-averaged thrust, which corresponds to 321.2 sec of effective specific impulse (ISP). As well, we measured the heat flux in the wall of PDE tubes. The heat flux was approximately 400 ㎾/$m^2$. We constructed the PDR-Flight Mode] (PDR-FM). In the vertical flight test in a laboratory, the PDR-FM was flying and keeping its altitude almost constant during 0.3 sec.

  • PDF

Resource Allocation Based on the Type of Handovers in Overlaid Macro-Femto Networks

  • Lee, Jong-Chan;Lee, Moon-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.1
    • /
    • pp.49-57
    • /
    • 2016
  • In this paper we propose the resource allocation scheme for the overlaid macro-femtocell networks, which considers the type of handovers such as the inter-macrocell, macrocell-to-femtocell, femtocell-to-macrocell, or inter-femtocell in order to guarantee Quality of Service (QoS) and expand the accommodation capacity. Our proposed scheme takes into account the movement of mobile terminals, the QoS degradation, or the load control which trigger handovers in the overlaid networks, before it allocates resources dynamically. Moreover it considers QoS requirements of realtime or non-realtime mobile multimedia services such as video communication, Video on Demand (VoD) and dataa services. Simulation results show that our scheme provides better performances than the conventional one with respect to the outage probability, data transmission throughput and handover failure rate.

Development of Rain Gauge and Observation Error (우량계 개발과 측정 오차)

  • 김대원;이부용
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1055-1060
    • /
    • 2002
  • A new method of automatic recording raingauge is developed to measure rainfall 1200mm full scale with high accuracy and resolution. The principle of new instrument is to detect a weight change of a buoyant weight according to a change in water level of raingauge measured by the use of a strain gauge load cell. This method has the advantage of increasing measurement accuracy, since no moving equipment is used. Laboratory test of the instrument was recorded 0.4% error of 190mm rainfall amount. The validity of new instrument was examined by comparing its measured values with values recorded by automatic weather station on June 24 to 25 2001 at Daegu Meteorological Station, when there is 148.3mm rainfall amount. In spite of much rainfall there is only 0.77mm difference of total rainfall amount. This instrument was accomplished high accuracy and resolution at field test in much rainy day.

Enhanced Adaptive Beamforming and Null Steering Algorithms in Cognitive Radio System

  • Zhuang, Zhili;Sohn, Sung-Hwan;Kim, Jae-Moung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11A
    • /
    • pp.822-830
    • /
    • 2009
  • The spectrum efficiency of mobile communication networks can be improved dramatically adopting multiple antennas technologies. In order to guarantee the licensed rights of primary user (PU), the cognitive radio system should perform in a relatively low interference manner when it gets access to the spectrum of licensed networks. In this paper, we explore a uniformly distributed circular antenna array to implement beamforming algorithm that is accomplished by optimization method at the base station of cognitive radio networks, and therefore we can suppress the interference to PU by steering quite low transmission power toward PU and constructing a narrow beam toward cognitive user (CU). By reducing the constraint number of the optimization problem, we also propose a null steering algorithm that steers rather low radiation power toward PU, while the other areas in the same cell are covered by radiation power except the local area around PU. It is pursued to reduce the computation load and enlarge the capacity of cognitive radio networks extremely. The simulation results demonstrate that the proposed algorithms process superior performance.

A Multi-physics Simulation and Measurement for Buoyancy of Nonmagnetic Solid Object Submerged in Magnetic Liquid (자성유체에 잠긴 비자성체 부상현상의 다중물리수치해석 및 실험)

  • Choi, Hong-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.43-48
    • /
    • 2013
  • In this paper, magnetic buoyancy force on nonmagnetic solid object submerged in magnetic liquid was simulated and measured. For the evaluation of the force, a multi-physics approach of hydrostatic equilibrium considering magnetic body force as well as gravity is presented. The magnetic body force should be regarded as an additional forcing term in the momentum equation of hydrodynamics. It is also shown that the virtual air-gap based Kelvin's force formula is a useful method for the calculation of force distribution in the magnetic liquid. The experimental result which was performed by a load-cell measurement system agreed quantitatively well with the numerical one.

A Study on the Design of Step Up DC-DC Converter and Parallel Operation (승압형 DC-DC 컨버터의 설계 및 병렬운전에 관한 연구)

  • 서광덕;홍찬욱;설승기;박민호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.579-587
    • /
    • 1992
  • This paper is to study on the step-up DC-DC converter for power system which yields output characteristics of low voltage and high current, such as fuel cell generation system. DC-AC-DC scheme is suggested for high ratio of voltage conversion. Three phase MOSFET-SPWM inverter is adopted for intermediate AC conversion and inverter output frequency is chosen at 400[Hz] in order to reduce the size of magnetic circuit and DC filter. Since control strategy which combines voltage controller with current controller in parallel is used, good output performance is obtained both in steady state and in transient state like load variation, not only in single unit operation but also in parallel operation.

A Study on the Measurement of Tension and the Tension Control for a Wire Rope (와이어 로프 제조공정의 장력 계측과 제어에 관한 연구)

  • 박성수;홍순일;윤정환
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.217-220
    • /
    • 2000
  • 현재, 선박용 로프제조에서 로프의 제조 공정은 수작업에 의해 행해지고 있어 작업의 효율화와 품질의 균질화를 위해서 최적의 장력제어가 필요하다. 본 연구의 목적은 와이어 로프 제조공정의 자동화이고 로프의 제조 공정에서 장치는 로프를 릴에 감아 올릴 필요성은 거의 없기 때문에 케이블을 풀어주는 속도와 로드셀에 의해 장력을 검출하고 장력을 발생하는 하드웨어 구성방법을 연구하는 것이다. 본 연구는 현수형 와이어 로프(Catenary Rope)의 동적 모델링을 작성한다. 이 시스템에 대하여 교류서보 전동기를 이용한 장력 발생장치를 모델링한다. 현수형 시스템의 장력 계측 장치는 하중 변환기(load cell)를 사용하고 수학적 모델링을 행한다. 장력 계측 장치에 관해서 스프링 저울을 이용해 출력을 비교 검토한 결과, 인장력을 계측하는 장치로서의 유효성을 확인하였다.

  • PDF

Development of UHF Partial Discharge Sensor for Intelligent distribution Facilities (지능형 배전기기를 위한 UHF 부분방전 센서 개발)

  • Cho, Young-Jun;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Song, Il-Gun;Lee, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.161-162
    • /
    • 2007
  • This paper is analyzed the internal type UHF sensors that be able to monitor the condition of the distribution facilities and the location selecting of that sensors. It set the PD cell on the inside of 22.9kV load switchgear and then it executed Partial Discharge test. it introduced the result of the test.

  • PDF