• Title/Summary/Keyword: Korean concrete Institute

Search Result 4,814, Processing Time 0.031 seconds

Evaluation on compressive strength of steel-concrete composite piles using a large scaled UTM(Universal Test Machine) (대형 UTM을 이용한 강관합성 말뚝재료의 강도 특성 평가)

  • Lee, Ju-Hyung;Kwon, Hyung-Min;Park, Jae-Hyun;Kwak, Ki-Seok;Chung, Moon-Kyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.482-489
    • /
    • 2009
  • Various model piles with different sections such as reinforced concrete, steel, steel-concrete composite without rebar and steel-concrete composite with rebar were made, and vertical load test was conducted using a large scaled UTM(Universal Test Machine) to evaluate Young's modulus and ultimate load of the model piles. Based on the tests, ultimate load of steel-concrete composite pile is 31% greater than the sum of it of reinforced concrete pile and it of steel pile. This is caused that ultimate load and Young's modulus of inner concrete increase due to confining effect by outer steel casing. Variation of ultimate load is also insignificant depending on the ratio of length to diameter(L/D), therefore bucking has not an effect on change of ultimate load in case of the L/D below 10.

  • PDF

Compressive strength properties of concrete using Waste Concrete Powder as a cement substitute (폐콘크리트 미분말을 시멘트 대체제로 활용한 콘크리트의 압축강도 특성)

  • Kim, Young-Kyu;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.128-129
    • /
    • 2015
  • Recently, a number of problems due to the CO2 emissions are occurred. Therefore, it is a movement to restrict this activity. The research is being carried out steadily for recycling waste concrete from the cement paste based fine powder, which accounts for over 60% of construction waste as a recycled cement. In this study, the conclusion was obtained as a result of the research conducted, and then, replacing the main material of cement concrete to solve the above problem by reducing the amount of cement used Waste Concrete Powder. The more concrete results page replacement ratio of fine powder increases, the flow value of the concrete is lowered, the strength was remarkably reduced when the page Concrete Powder.

  • PDF

Literature study on the improvement of lightweight concrete in perspective of foaming agent (기포제 관점에서 경량기포 콘크리트의 개선방향에 관한 문헌적 연구)

  • Choi, Myeong-In;Lee, Han-seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.141-142
    • /
    • 2015
  • This literature study is focused on the improvement of lightweight concrete in perspective of foaming agent. Lightweight concrete is the cured concrete as putting required amount of foaming agent to slurry which is a mixture of a certain amount of cement, sand, and water. It has lower density than general concrete, because foaming agent disintegrates numerous bubbles evenly and independently. Thus, it is capable of lightening the weight and great for sound absorption and insulation, In foreign countries, studies for structural lightweight concrete mainly of tunnel grouting and weight lightening of heavy structures are going along actively. Domestically, exterior panel and ALC blocks are alternatively used for flooring. Therefore, this research consider improvement of lightweight concrete in perspective of foaming agent with foundation study.

  • PDF

A Fundamental Study on the Control of Hydration Heat of Mass Concrete Using Setting Time Difference (응결시간차를 활용한 매스콘크리트의 수화열 조정에 관한 기초적 연구)

  • 배정렬;윤치환;김기철;한민철;오선교;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.41-45
    • /
    • 2002
  • Placing lift is applied to place mass concrete in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

A Study on the Physical Properties of Concrete Using Drying Shrinkage-Reducing Superplasticizer (건조수축 저감형 유동화제를 사용한 콘크리트의 물리적 특성에 관한 연구)

  • Shin Jae-Kyung;Oh Chi-Hyun;Choi Jin-Man;Lee Seong-Yeun;Han Min-Cheol;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.215-218
    • /
    • 2005
  • This paper intended to evaluate the applicability of drying shrinkage reducing superplasticizer (DSRA) by investigating physical properties of concrete using DSRA, The application of flowing concrete method exhibited a less loss of slump and air content with time than those of conventional concrete and had small bleeding. Flowing concrete had larger compressive strength than base and conventional concrete by as much as $3\~5\%$. It also had less drying shrinkage by as much as $20\%$ compared with conventional concrete. This is due to the coupled effect of reduced water content and aqueous type expansive admixture. On the other hand, neutralization depth of flowing concrete showed greater than conventional concrete.

  • PDF

Drying Shrinkage Cracking of Concrete used Very Fine Sand (미립 잔골재를 혼입한 콘크리트의 건조수축 균열 특성)

  • Lee, Eui-Bae;Park, Sang-Jun;Kim, Kyoung-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.90-91
    • /
    • 2014
  • In this study, the effect of very fine sand on drying shrinkage cracking of concrete was experimentally evaluated. As a result of the study, the time-to-cracking of concrete used very fine sand was shorter than plain concrete. Also, the stress rate of concrete used very fine sand was higher than plain concrete. It was due to the increase of water content when very fine sand was used in concrete. In conclusion, the use of very fine sand can lead the increase of water content to meet the target slump and higher potential of cracking of concrete.

  • PDF

Quality Variation of Concrete Containing Beverage and detergent During Placement (콘크리트 타설시 음료 및 세제류 유입에 따른 품질변화)

  • No Dong-Hyun;Kim Jong-Back;Hwang Yin-Seong;Li Bai-Shou;Yang Seong-Hwan;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.85-88
    • /
    • 2005
  • This study investigates influence on concrete adding beverage or detergent, by work man's mistakes during concrete placement in field. Overall, concrete adding beverage or detergent does not affect slump and air content, compared with control concrete. However concrete adding detergent resulted in significantly higher air content, due to inter facial activation ingredient. For the properties of setting time, concrete adding lactic acid beverage indicated the longest retarding properties, next was coffee and soft drink in order. Compressive strength of concrete, which retarded setting time. exhibited slightly improved value at 7 and 28 days respectively, while that of concrete adding detergent significantly decreased, due to higher air content.

  • PDF

Propose of Eco-efficiency Evaluation Method for Concrete (콘크리트의 에코효율성 평가방법 제안에 관한 연구)

  • Kim, Tae-Hyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.187-188
    • /
    • 2016
  • The purpose of this study is to develop a method of evaluating eco-efficiency of concrete based on environmental load emission, manufacturing cost, and durability in the concrete production process. Eco-efficiency is an advanced concept used to evaluate eco-friendliness of concrete. This technique intends to produce environment-friendly and highly durable concrete while minimizing environmental load on the ecosystem and manufacturing cost based on the results of service life assessment on concrete. This technique can be utilized to efficiently evaluate sustainability of concrete and find methods to improve it. Furthermore, the vision of this study is to contribute to implementation of environment-friendly concrete and construction industry.

  • PDF

A Study on the Manufacture and Application of Ultra-high Strength Concrete (초고강도 콘크리트의 제조 및 현장적용성에 관한 연구)

  • Choi, Il-Ho;Jung, Yang-Hee;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.1-4
    • /
    • 2007
  • Because reinforced concrete structures were being high more and more in recent year, concrete was being demanded high performance of high strength and high fluidity. But various characteristics must be confirmed besides guarantee of demand strength in ultra-high strength concrete. In ultra-high strength concrete, autogenous shrinkage and drying shrinkage grow big because of a low water cement ratio and much quantity of binder. So dangerousness of crack generation grow big in early ages. And ultra-high strength concrete is influenced by use materials more than ordinary strength concrete. In this study we were examined mix design, atuogenous shrinkage and pumpability of ultra-high strength concrete to apply on the ground.

  • PDF

A Study on the Flexural Rigidity Change according to Quantities Characteristics of Waterproof Admixture for Concrete (콘크리트용 수밀 혼화재 첨가량에 따른 휨 강도 변화추이 연구)

  • Choi, Su-Young;Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.128-129
    • /
    • 2017
  • Concrete properties alone cannot provide satisfactory waterproof performance because concrete can generate cracks due to possible problems in design, construction and curing process, and various environmental factors. Therefore, concrete structures require installing waterproofing layers for concrete protection and various types of construction methods are currently being applied. The purpose of this study is to investigate the concrete strength changes when waterproofing admixtures are mixed into the concrete. The results of flexural strength testing confirmed that the initial strength of concrete specimens with the admixtures was lower than that of the concrete specimen without the admixture based on different curing periods.

  • PDF