• Title/Summary/Keyword: Kit

Search Result 2,352, Processing Time 0.03 seconds

Assay of Human Chorionic Gonadotropin in Urine of Athletes and Evaluation of Assay Kit Performance (운동선수들의 뇨 중 Human Chorionic Gonadotropin 분석 및 분석킷트 평가)

  • 최명자;이정란;김명수
    • Biomolecules & Therapeutics
    • /
    • v.10 no.3
    • /
    • pp.186-192
    • /
    • 2002
  • Special attention has been paid to human chorionic gonadotropin (hCG) for athlete doping control because it stimulates the endogenous production of testosterone and epitestosterone without increasing the T/E ratio which is a doping indicator for the exogenous administration of testosterone. Even though the IOC banned the use of hCG, a detection method has not been decided upon since there are a variety of immunoassay kits available on the market. We evaluated three kits in terms of their performance characteristics. The assay value of the control sample varied depending on the kit, resulting in 198 mIU/ml for the MAIA kit, 172mIU/ml for the IRMA kit, and 143 mIU/ml for the MEIA kit. Considering the IOC inter-lab distribution of results(55-312 mIU/ml) using 27 different kits and the mean value (178$\pm$56 mIU/ml), all three kits are within the range of -15.8% - +5.6% of the mean value, which proves them useful for the hCG assay. The MEIA kit resulted in lower hCG values because it detects only intact hCG molecules, in contrast to the other two kits which detect intact hCG and -hCG together. However, it is suitable for screening purposes because of its advantage of being an automated system. When 123 urine samples of athletes were analyzed in 22 batches using this system, the variation of control values fell within $\pm$ 10% of the mean values, and an specimens tested negative with hCG values less than the detection limit of 2 mIU/ml.

C-kit Protein Expression and Mutation Analysis in Adenoid Cystic Carcinomas (샘낭암종에서의 C-kit 단백 발현 및 돌연변이 분석)

  • Cho Kyung-Ja;Choi Jene;Kim Sang-Yoon;Nam Soon-Yuhl;Choi Seung-Ho;Kim Sung-Bae
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.2
    • /
    • pp.158-163
    • /
    • 2003
  • Objectives: To document the incidence and pattern of c-kit protein expression & mutation in adenoid cystic carcinomas. Materials and Methods: Twenty-five cases of adenoid cystic carcinomas of the major and minor salivary glands and the upper and lower respiratory tract were subjected to the immunohistochemical study for ckit(CD117 ; Dako). Nineteen cases of them were analyzed for mutations in exon 11 and exon 17 by PCR-SSCP, and in cases of need, by DNA sequencing. Results: Twenty-three cases (92%) showed c-kit expression, but none showed mutations in exon 11 and exon 17. The expression was restricted to the inner luminal cells in all tubular types and most of cribriform adenoid cystic carcinomas, while the staining was diffuse in all solid variants and two cribriform types. Conclusion: C-kit expression was common in adenoid cystic carcinomas, regardless of their origins. Although genetic bases await further studies, a clinical trial of tyrosine kinase inhibitors in adenoid cystic carcinomas, especially in solid variants, is considered encouraging.

Remote practice of AVR system (AVR 시스템의 원격 실습방법)

  • Kim, Byun-Gon;Baek, Jong-Deuk;Kim, Myung-Soo;Jeong, Kyeong-Taek;kwon, Oh-Shin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.751-753
    • /
    • 2017
  • In this paper, we implement remote training kit using camera, Arduino and AVR practice kit so that AVR practice kit can be practiced remotely. Implemented systems can be practiced by a large number of users one at a time from a remote location. The practitioner creates the AVR Studio program using the PC remote control method and downloads it to the AVR training kit. When a computer program is created and a mouse is clicked or dragged, the input signal is transmitted to the Arduino and the Arduino transmits the actual button input signal or the analog voltage to the AVR kit. When the AVR kit is activated by receiving the input signal, you can check the operation through the camera. Therefore, using the implemented system, a plurality of users can perform AVR training using one kit.

  • PDF

A Study on Satisfaction with Makeup-kits and Makeup-kit Brand Development -Focused on Lifelong Education Centers of Colleges-

  • Kim, EunSil;Chung, Ju-Im
    • Journal of Fashion Business
    • /
    • v.19 no.3
    • /
    • pp.31-42
    • /
    • 2015
  • The purpose of this study is to develop a new makeup-kit brand for education, analyzing customer satisfaction of makeup-kits used in makeup lessons provided by lifelong education centers of colleges. The research method is as follows. In order to understand the current status of the kits used in makeup lessons offered by lifelong education centers of colleges in South Korea, the study conducted a survey from October 10 of 2014 to October 31 via fax, telephone and e-mail targeting these 98 colleges that were open makeup-courses available in October 2014. As for an analysis technique, the study used a frequency analysis. In order to develop a makeup-kit brand, the study investigated these makeup-kits as well and presented a BI draft and a makeup-kit design that the study had created for itself using Photoshop CS6 and Illustrator CS4. According to findings of the survey, the students were not satisfied with kits that had too many items, were high in price and had poor case design. In the light of that, the study conducted to develop a low to middle priced makeup-kit ranging from 110,000 KRW and 150,000 KRW with approximately 26 items. In terms of a case design, black was a dominant color which would make the case feel simple and modern. Dimensions of a small size makeup-kit container were 22cm*35cm*37cm with a sponge and rubber pad proposed as product ideas. The study also worked on a BI design.

Evaluation of the Kit's Efficiency of Alpha Fetoprotein (AFP) Test (Alpha feto protein(AFP)검사 키트의 유효성 평가실험)

  • Cho, Hyun-su;Noh, Gyeong-woon;You, Tae-min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.101-104
    • /
    • 2018
  • Purpose Alpha fetoprotein(AFP) is a fetal serum protein that increases in germ cell tumors derived from liver cancer or egg yolk. AFP test has been used for screening of liver cancer, determination of tumor stage, determination of therapeutic effect, and fetal congenital malformations. The purpose of this study was to compare the results of the four kits, identify the advantages and disadvantages of each kit, and select the appropriate kits for our laboratory. Materials and Methods Blood samples were obtained from 89 patients attending the Seoul national university hospital. Experiments were carried out in accordance with manufacturer's instructions of four companies(A, B, C, D). The precision, recovery, linearity, and sensitivity test were performed for each kit. Results In case of the precision within the measurement, the CV value of the C kit was less than 5% at the low, middle, and high concentrations. The A, B and D kit's the CV value was less than 5% at the concentrations except the low concentration. The recovery rates of the A, B, C, and D kits were $100{\pm}15%$, $100{\pm}30%$, $100{\pm}16%$ and $100{\pm}14%$, respectively. All kits showed good linearity. Sensitivity was measured as 0.5 IU/mL for A, 0.4 IU/mL for B, 0.98 IU/mL for C, and 0.3 IU/mL for D. Conclusion The CV values of the four kits were within 10%, and the correlation coefficients were close to 1 for $R^2=0.978$, $R^2=0.992$ and $R^2=0.8957$. As a result, they are clinically available. Therefore, each laboratory should select the appropriate kit for their experiment's environment.

Fermented Colostrum Whey Upregulates Aquaporin-3 Expression in, and Proliferation of, Keratinocytes via p38/c-Jun N-Terminal Kinase Activation

  • Seo, Sang-Ah;Park, Hyun-Jung;Han, Min-Gi;Lee, Ran;Kim, Ji-Soo;Park, Ji-Hoo;Lee, Won-Young;Song, Hyuk
    • Food Science of Animal Resources
    • /
    • v.41 no.5
    • /
    • pp.749-762
    • /
    • 2021
  • Colostrum, which contains various immune and growth factors, aids wound healing by promoting keratinocyte proliferation. Aquaporins (AQPs) are small, hydrophobic membrane proteins that regulate cellular water retention. However, few studies have examined the effect of processed colostrum whey on AQP-3 expression in human skin cells. Here, we investigated the effect of milk, colostrum, fermented milk, and fermented colostrum whey on AQP-3 expression in keratinocyte HaCaT cells. Concentrations of 100-400 ㎍/mL of fermented colostrum whey were found to induce HaCaT cell proliferation. AQP-3 was found to be expressed exclusively in HaCaT cells. AQP-3 expression was significantly increased in 100 ㎍/mL fermented colostrum whey-treated cells compared with that in controls. Moreover, fermented colostrum increased p38 mitogen-activated protein kinase (MAPK) and c-Jun N-terminal kinase (JNK) phosphorylation, but not ERK1/2 phosphorylation. Thus, our results suggest that fermented colostrum whey increased AQP-3 expression in, and the proliferation of, keratinocytes via JNK and p38 MAPK activation.

Carbon Dioxide Reforming of Methane over a Ni/KIT-1 Catalyst (Ni/KIT-1 촉매를 이용한 메탄의 이산화탄소 개질반응 연구)

  • Ryn, Seong-Yun;Ahn, Wha-Seung;Park, Sang-Eon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.1070-1078
    • /
    • 1998
  • Thermodynamic analysis on carbon dioxide reforming of methane was performed using a computer program which can handle condensed species in the products, and the reforming experiments were conducted over $Al_2O_3$, $La_2O_3$, ZSM-5, MCM-41, KIT-1 supported nickel catalysts, and a commercial ICI 46-1. It was estabished that a system which consists of $CH_4$, $CO_2$, CO, $H_2$, $H_2O$, and C is appropriate for theoretical equilibrium calculations and addition of water vapor or oxygen was found to diminish the contribution of carbon dioxide in reforming. Silicate molecular sieve-supported catalysts such as Ni/ZSM-5, Ni/MCM-41, Ni/KIT-1 were effective for high $CH_4$ and $CO_2$ conversions as well as for high CO yield. Coke formation was suppressed when CaO was added as a promoter. Ni/Ca/KIT-1 which contains 10% Ni with 3% Ca showed conversion approaching equilibrium levels above $650^{\circ}C$ and maintained constant activity over 20 h. Despite increased space velocity, relatively high conversion and CO yield were observed.

  • PDF

Performance Evaluation of PCR Kits for Detecting Genetically Modified Crop Ingredients (유전자 변형 작물 성분 검출용 PCR Kit의 성능 평가 연구)

  • 윤시온;정순천;윤원기;박상규;문제선;이정현;김환묵
    • Toxicological Research
    • /
    • v.20 no.2
    • /
    • pp.101-108
    • /
    • 2004
  • The different social reflections about the benefits and the potential risks of genetically modified (GM) crops have evolved with .different reactions in different countries. Many countries including Korea are working toward setting down new guidelines. Korea requires companies to label all food that contains more than 3% GM ingredients. One of the rapid and convenient detection methods of GM ingredients is amplification of the introduced DNAs by polymerase chain reaction (PCR). Many PCR kits for this purpose are commercially available. The objective of this study was to evaluate performance of commercialized GM crop detection kits. The results showed that 6 out of 15 kits tested did not meet the requirements even purposed by the manufacturers themselves in terms of stability, reproducibility, and detection limits, suggesting a potential quality control problem in their design stage or production line. The evaluation also suggests that, although the duplex and triplex detection kits allowed unambiguous detection in a single PCR reaction, the monoplex detection kits were the most sensitive to the detection of GM ingredients. The detection limits also differ between soybean and corn. Results from this study will be useful in the development of sound qualitative tracking systems of GM ingredients for monitoring throughout the cultivation of GM crops, their trans-boundary movement, and food production using GM grains as well as for complying with government guidelines associated with GM crops.

Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay (면역방사 계수측정법 (Immunoradiometric, Assay)에 의한 혈청 TSH 측정의 기본적 검토 및 임상적 의의)

  • Suh, Kyo-Il;Cho, Bo-Youn;Lee, Hong-Kyu;Koh, Chang-Soon;Min, Hun-Ki;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.143-150
    • /
    • 1987
  • To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit $(Abott^{(R)}\;and\;Daichi^{(R)})$. Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 voluteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intra assay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/l respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU/l. Mean recoveray rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/l and 2.85-30.8 mU/l repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function.

  • PDF

Tests of a Guidance Kit for Air-to-Surface Bomb (공대지 폭탄용 유도키트 시험)

  • Lee, Inwon;Lee, Kidu;Park, Youngkuen;Lim, Sangsoo;Baek, Seungwoock;Lee, Daeyearl
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.4
    • /
    • pp.314-318
    • /
    • 2013
  • Tests and evaluations following the U.S. MIL-HDBK/STANDARD were successfully conducted to assure the performance of the air-to-surface guidance kit which was developed first in Korea. Various ground tests confirmed the operation capability and reliability of the guidance kit, and flight tests proved very good mid-range gliding performance and accuracy of the gliding bomb which was a general purpose bomb with the guidance kit.