Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay

면역방사 계수측정법 (Immunoradiometric, Assay)에 의한 혈청 TSH 측정의 기본적 검토 및 임상적 의의

  • Suh, Kyo-Il (Department of Internal Medicine, College of Medicine, Seoul National University) ;
  • Cho, Bo-Youn (Department of Internal Medicine, College of Medicine, Seoul National University) ;
  • Lee, Hong-Kyu (Department of Internal Medicine, College of Medicine, Seoul National University) ;
  • Koh, Chang-Soon (Department of Internal Medicine, College of Medicine, Seoul National University) ;
  • Min, Hun-Ki (Department of Internal Medicine, College of Medicine, Seoul National University) ;
  • Lee, Mun-Ho (Department of Internal Medicine, College of Medicine, Seoul National University)
  • 서교일 (서울대학교 의과대학 내과학교실) ;
  • 조보연 (서울대학교 의과대학 내과학교실) ;
  • 이홍규 (서울대학교 의과대학 내과학교실) ;
  • 고창순 (서울대학교 의과대학 내과학교실) ;
  • 민헌기 (서울대학교 의과대학 내과학교실) ;
  • 이문호 (서울대학교 의과대학 내과학교실)
  • Published : 1987.11.13

Abstract

To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit $(Abott^{(R)}\;and\;Daichi^{(R)})$. Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 voluteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intra assay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/l respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU/l. Mean recoveray rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/l and 2.85-30.8 mU/l repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function.

Keywords