• Title/Summary/Keyword: KS (Korea Standard)

Search Result 423, Processing Time 0.028 seconds

Development of cooking method for senior-friendly food using fruits suitable for older adults with masticatory dysfunction

  • Dasol Kim;Jihye Ryu;Hee-Sook Lim;Yong-Seok Kwon
    • Nutrition Research and Practice
    • /
    • v.18 no.2
    • /
    • pp.223-238
    • /
    • 2024
  • BACKGROUND/OBJECTIVES: The purpose of this study was to establish a fruit-cooking method suitable for older adults with masticatory dysfunction. MATERIALS/METHODS: Five types of fruits were selected to make fruit jelly and puree: apple, sweet persimmon, mandarin, Korean melon, and watermelon. Recipes were selected based on the Korean Industrial Standard (KS) for senior-friendly foods (KS H 4897), which classifies foods into 3 levels (L1-L3) based on their hardness and viscosity. RESULTS: In South Korea, senior-friendly foods are classified into 3 stages based on their hardness. Stage 1 is for foods that are able to eat with teeth (hardness greater than 50,000 N and less than 500,000 N), Stage 2 is for foods that are able to eat with gums (hardness greater than 20,000 N and less than 50,000 N), and Stage 3 is for foods that are able to eat with the tongue (hardness less than 20,000 N). As a result of measuring the hardness by varying the shape of the fruit, it was found that nearly all fruits could be eaten fresh by chewing with the teeth (L1) but did not meet the KS for mastication using the gums (L2) or tongue (L3), so the cooking method was selected as fruit jelly and fruit puree. Only sweet persimmon, which had a hardness of 61,624-496,393 N, was not suitable for consumption in fresh fruit, unprocessed form. Based on their hardness measurements, fruit jellies (27,869 to 36,343 N) and fruit purees (315 to 1,156 N) met the L2 and L3 requirements, respectively. The viscosity results of all fruit purees met the L3 requirement. CONCLUSION: These results offer a simple cooking method to prepare texture-modified fruits suitable for safe consumption by older adults living with masticatory difficulties in general households and nursing facilities.

The Methods of the Activation of Korean Private sector-driven Standardization for coping with the Dynamic International Standards (변화하는 국제표준에 효과적으로 대응하기 위한 우리나라의 민간표준화 활성화 방안 연구)

  • 이강인;정재익;최순양
    • Journal of Korean Society for Quality Management
    • /
    • v.31 no.3
    • /
    • pp.62-84
    • /
    • 2003
  • The typical reason of the private sector's increasing share in standardization is that the procedures of official standardization organizations are out of step with the rate of technical development. At today's so fast pace that the success of a technology is decided in the market even before it is standardized, several industry leaders jointly make their draft standard at the early stage of development, which becomes 'De fecto Standard.' To respond effectively to current trends of standardization where the market's decision is thought much of than official standardization procedures, it is necessary to shift from our current public sector-driven to private sector-driven standardization. Therefore, to vitalize the private sector-driven standardization in Korea, there is a need to: Run a standard foundation to secure stable resources for standardization Make information exchange between the govertment and private sector active and policy-making on standards consistent by designating a private organization to cover the roles, policies on standards, and support of the national standardization organization Establish a system to make private sector-driven standards approved as international standards Offer a training program to forster standard experts Publicize the importance of standards Promote standardization forums driven by private businesses, like the Integrated Forum. Maximize the benefits of linking standards and patents Now, Korea is on the threshold of developing into a world-class standard leader, and the private sector-driven standardization should be a stepping-stone for crossing over the threshold. This study is designed to suggest a method of promoting private sector-driven standardization to effectively cope with fast-changing international standards, based on the cases in developed countries.

The Study on Filling Factor of Radiation Shielding Lead-free Sheet Via Screen Printing Method (스크린 프린팅 공법을 통한 방사선 무연 차폐 시트에 관한 연구)

  • Kang, Sang-Sik;Jeong, Ah-Rim;Lee, Su-Min;Yang, Seung-Woo;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.713-718
    • /
    • 2018
  • In many previous studies, monte carlo simulation is used to produce lead-free shielding sheet, and the possibility of radiation shielding capability and weight reduction is presented. But it is difficult to simulation for binder and micro-pores because of In fact it does not provide sufficient information necessary for the commercialization process. Therefore, in this paper, the results of radiation shielding capability corresponding to filling factor was presented by using the screen printing method to provide information on gel-paste required for the commercialization process. In this study, the geometric setup for evaluate of radiation shielding ability was designed to comply with IEC 61331-1:2014 and KS A 4025. In addition, radiation irradiation conditions were 100 kVp filtered with 2.0 mmAl total filtration was applied according to KS A 4021 standard. In this study, Pb $1270{\mu}m$, $BaSO_4$ $3035{\mu}m$, $Bi_2O_3$ $1849{\mu}m$ and $WO_3$ $2631{\mu}m$ were analyzed based on ten value layer. Additionally, the filling factor was analyzed as $BaSO_4$ 38.6%, $Bi_2O_3$ 27.1%, $WO_3$ 30.15%. However, in the case of applying low-temperature high-pressure molding in the future, it is expected that the radiation shielding capability can be sufficiently improved by reducing the porosity while increasing the filling factor.

A Study on the Strength at an Early Stage of the Compound Mixed into Polycarboxylate (Polycarboxylate에 혼합 사용된 혼화제의 조기강도 발현성상에 관한 연구)

  • Ryu, Hyun-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.6
    • /
    • pp.175-181
    • /
    • 2009
  • In this research, experiments were conducted to find out whether polycarboxylate could be used as a crude steel admixture for practical work, depending on the change in the replacement level of the compound mixed into polycarboxylate. Its fluidity was satisfactory, its airspace was a bit smaller than the KS standard, and its unit volume weight was proven to meet the standard. The amount of bleeding was smallest in B2, and in terms of the solidification time, the first and the last solidification was faster in A1, B1, and C1. With regard to the compressive strength in early days as acharacteristic of hardened concrete, all addition rates of 7-day C2 displayed the highest strength value, among which the addition rate of 1.3% had the biggest strength performance tendency. The seal strength also showed the strength performance rate which was about one tenth as big as that of the compressive strength. The length change rate resulting from dryness and contraction was proven to be good, and once the appropriate AE air entraining agent is used, it is evaluated to be a very useful and practical compound out in the field.

A Study of Adhesion Process on the Footwear Cotton Fabric Treated with Sericite Antibacterial Agent (Sericite 항균처리 신발용 면직물의 접착공정 연구)

  • Yoon, Rae Won;Lee, Jae Ho;Cho, Hyun Hok
    • Journal of Adhesion and Interface
    • /
    • v.7 no.2
    • /
    • pp.32-38
    • /
    • 2006
  • In this study, we used a sericite which is a cheap price antibacterial agent and had excellent results. The particle size of sericite was fixed to $15{\mu}m$. The effect of the peel strength is not affected by several types of adhesives. Peel strength is increased with increasing adhesive content, and satisfied standard value of peel strength when adhesive content is $20g/m^2$. Laundering cotton fabric treated with antibacterial agent, the optimum content satisfying Korean Standard (KS) is 8%. Continuous processing conditions for antibacterial treatment on the footwear cotton fabrics are follows : melting temperature $120^{\circ}C$, cooling time 20 s, pressing temperature $130^{\circ}C$, pressing time 30 s.

  • PDF

A Study on the Traditional Color Analysis of Chinese Historic Village - Focus on Cuandixia Village of Mentougou District in Beijing - (중국 민속(民俗)마을의 전통(傳統)색채 분석에 관한 연구 - 북경(北京)시 문두구(門頭溝)구 천저하마을(爨底下村)을 대상으로 -)

  • Ma, Yuan;Lim, Jin-Kang;Kim, Dong-Chan
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.33 no.4
    • /
    • pp.112-128
    • /
    • 2015
  • To consider an identity about traditional folk village, this study analyzes color characteristic of traditional folk village by targeting Cuandixia folk village in China. For method of study, color is analyzed by KSCA(Korea Standard Color Analysis) program and images of color are drawn by I.R.I. Based on these, four results are came out. First, color distribution of Cuandixia is appeared in YR, R, Y, GY order. Furthermore, there are no affiliation of BG, and B but a lot of affiliation of YR. Second, the whole is made up of color that is applied to mist gray/low chroma in the value and chroma stakes. Especially, high chroma is extracted by only commercial old house, the rest is made up of middle and low chroma color. Third, dark color is the most by KS Color System and dark reddish gray and medium gray are occupied most part. Fourth, the whole atmosphere of village is static and hard, and the image is researched as gentle. Through the research, It applies extracted color palette for plan and preservation of traditional folk village. As using the color that is reflected in national and local distinct characteristic, preserving the color reflected in history and culture of the village, and applying color planning considered harmony with surrounding environment, it is expected that it can help to direct the color involved traditional and cultural meaning.

A Study on the Standard Test Method for Thermal Resistance of Military Textile Thermal Insulator for Winter Season (방한을 목적으로 하는 군용 섬유제품 충전재의 보온성 시험방법에 대한 표준화 연구)

  • Yeo, Yong-heon;Hong, Seong-don;Lee, Min-hee;Kim, Kyung-pil;Chung, Il-han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.492-500
    • /
    • 2018
  • The performance evaluation of cold weather clothing is mainly carried out with thermal resistance. However, the results of the revised test method regarding the same specimen were decreased compare to previous one. In addition, there were deviations of the results among the authorized testing institutes according to the different interpretation of the KS test method. This makes it a considerable difficulty to the quality assurance of combat supplies. The purpose of this study is to minimize the variation of the results before and after the revision by analyzing the cause of the decrease in the heat insulation rate according to the revised test method. For this purpose, the difference between the test conditions before and after the revision of KS is analyzed and the possible results are reviewed. In addition, we want to minimize the result deviation between testing laboratories by analyzing the cause of the result deviation between test laboratories according to arbitrary interpretation of the standard. Based on this, we propose a standardized test method to prevent the decrease of the heat insulation rate by checking the pre-revision test method and the condition with the least deviation.

Estimation Method of the Interchangeability Using Equivalent Gases in a Partial Premixed Gas Appliance (등가가스를 이용한 부분예혼합 가스기기의 호환성 판정법)

  • Kim, Jong-Min;Lee, Seung-Ro;Ha, Young-Cheol;Lee, Sung-Min;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.761-766
    • /
    • 2010
  • The estimation method of the interchangeability in a partial premixed appliance about various compositions of natural gases using equivalent gases, experimentally. The results of the experiment in which equivalent gases were used compared with those obtained in experiments in which natural gases were used; Images of flames, lift-off limits, CO emissions, and incomplete combustion indices in KS standard for the domestic gas range were considered. From the comparison, it was observed that the length and color of the flame of the equivalent gases were almost the same as those of imported natural gases. Further, in the case of gases with Wobbe indices greater than 51 MJ/$m^3$, the KS standard for lifting limits was satisfied. Furthermore, in the case of gases with Wobbe indices less than 56.3 MJ/$m^3$, the CO mole fractions are in the range 95-100 ppm. Hence, the range of Wobbe indices 51-56.3 MJ/$m^3$ was proposed to be the range for interchangeability from the points of view of lifting limits and incomplete combustion, as prescribed in the domestic gas range in the case of imported natural gases.

A Study on the Performance Evaluation of Water(wash out) Resistance of 5-Type Repair Materials in Water Leakage of Underground Concrete Structures (지하 콘크리트 구조물 누수부위에 시공되는 5계열 보수재료의 유실 저항 성능 평가 연구)

  • Kim, Soo-Yeon;Yoo, Jae-Yong;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.61-68
    • /
    • 2020
  • In this study, the international standard ISO TS 16774 Part 3 Test Method for Water (wash out) Resistance and KS F 4935 「Sealant Injection type for water leakage maintenance of adhesive flexible rubber asphalt series」, which are standardized as a quality control method of injection type repair materials used for water leakage cracks in underground concrete structures, are currently used in Korea. As a result, considering the performance criteria of "mass change rate -0.1%" stipulated in KS F 4935, the remaining 13 types repair materials, excluding RG-2 of synthetic rubber and UG-1 of urethane, need to be reviewed for stabilization of the loss resistance due to the flow of ground water. The results of this study are determined to be available as a basic indicator for the selection of repair materials used for cracks in concrete structures. In addition, it is expected that the results of this study can be utilized as reference data that can be reflected in the improvement of the quality of repair materials that will be researched and developed later.

A Study of Air-source Heat Pump Performance Analysis for Replacing Night Time Electric Heating Boiler (심야전기보일러 대체용 공기열 히트펌프 성능평가)

  • Jo, J.Y.;Jung, H;Lee, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2011
  • The night time electric cost is cheaper due to electric supply and demand policy in Korea from 1985. Currently about 900,000 customers are using night time electric heating boilers and this causes shift of peak demand time to night in winter and increase of deficit spending. To solve this problem, replacing night time electric heating boiler by air-source heat pump using night time electricity has been proposed. An air-source heat pump can provide efficient heating equipment especially in a warm climate. For estimating the night time electric heat pump COP(Coefficient of Performance), Korean Standard KS C 9306:2010 and European Standard EN-14511:2004 is available. SCOP(Seasonal COP) using European weather bin data is also calculated. SCOP is not available yet but European Committee for Standardization will establish a standard in the near future. The evaluation result show that the replacing night time electric heating boiler by heat pump can be possible.