• 제목/요약/키워드: Jet-fire

검색결과 164건 처리시간 0.025초

불활성 압축가스를 이용한 미세물분무 소화시스템의 유류화재 소화특성 (Extinguishing of Oil Fire by Water Mist Suppression System Using Compressed Inert Gas)

  • 신창섭;전고운;김기환
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.109-114
    • /
    • 2010
  • Water mist fire suppression system is environmental system and needs a flange pump to jet water. In this research, high pressure Nitrogen cylinder is used as a pressurizing source instead of flange pump, and also we tried to find the possibility of using compressed Nitrogen as a fire suppression agent. As a result, it was possible to design water mist fire suppression system with Nitrogen cylinder and suppress oil fire effectively. With DK1.58 nozzle, the optimum Nitrogen pressure was 80bar and the pressure was stable during water mist spray. However, jet of Nitrogen was not effective fire suppression agent when it was dually used with water mist because water mist has blown away, and it is efficient way to use compressed Nitrogen as a pressurizing source only.

도로터널에서 제트팬 근처의 재순환유동과 연기 역류현상의 상호작용 분석 (Analysis of Interaction Between Recirculating Flow Near The Jet Fan and The Backlayer of Smoke in a Road Tunnel)

  • 김창균;유진웅;김성준
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.191-201
    • /
    • 2005
  • A numerical analysis was done for a tunnel fire in a 1000m road tunnel. A cartesian coordinate was adopted to make a computational grid sytem which has 448,000 computational cells. A transient flow phenomena in the tunnel was simulated by the commercial code of PHEONICS from the ignition of fire to 600 seconds by the interval of 100 seconds. Total computational time of about 44 hours was required to get a convered solution in each time step. The purpose of this research is to analyze of the backlayering pheonomena and recirculation flow in a tunnel. The compuational results say that the backlayering does not happens near the fire of vehicle in this case because the vehicle fire is located at the outside of recirculation zone of flow ocuured near the jet fan. In this research, onset of backlayering pheonomena could be escaped if jet fan is set 95m in front of the the fire of vehicle.

  • PDF

연소해석을 이용한 충돌형 제트분사기의 연소 안정성 평가에 관한 수치적 연구 (A Numerical Study on Combustion-Stability Rating of Impinging-Jet Injectors Using Hot-Fire Simulation)

  • 최효현;손채훈
    • 한국추진공학회지
    • /
    • 제14권5호
    • /
    • pp.24-31
    • /
    • 2010
  • 충돌형 분사기가 장착된 모델 연소실에서 연소장 수치 해석을 이용하여 연소 안정성을 평가하였다. 충돌형 분사기로는 F(fuel)-O(oxidizer)-O-F형 분사기를 채택하였다. 본 연구에서는 연료와 산화제의 제트 혼합과정이 지배적이라는 가정하에 순간 화학 반응 모델을 채택하여 수치해석을 수행하였다. 선행 연구를 통해 제안된 방법론을 토대로 모델 연소실 형상이 설계되고 연소실 작동 조건이 결정되었다. 본 연구에서 제시한 방법을 토대로 얻은 연소 안정성 경계는 공기 분사 음향 실험과 연소 실험결과와 정성적으로 잘 일치하였다. 연료와 산화제의 분사와 혼합이 연소 불안정 유발에 지배적인 경우, 본 연구에서 제안된 수치해석 기법을 이용하여 효과적으로 분사기의 연소 안정성을 평가할 수 있다.

플레어스택의 화염 형상 분석 (Analysis of Flame Shape in Flare Stack)

  • 이헌석;김범수;정상용;유진환;박철환;고재욱
    • 한국가스학회지
    • /
    • 제13권3호
    • /
    • pp.49-53
    • /
    • 2009
  • 릴리프시스템은 공정 내에 과압 방지하여 공정의 안전성을 높여주는 역할을 한다. 릴리프 시스템에서 방출되는 폐가스로 인한 폭발, 복사열, 독성가스 확산을 막기 위하여 플레어스택을 설치한다. 플레어스택에서는 공정의 안전성 향상을 위하여 안전한 연소가 가장 중요한 요소이며, 안전한 연소를 위하여 방출되는 가스량과 속도 제어는 API 521 code의 기술기준을 따르며, 플레어스택에서 발생하는 화염의 형상은 방출되는 가스의 압력과 질량유속에 의하여 jet fire의 형상을 하고 있다. 이는 화염의 형상은 완전 연소와 열 방출에 영향을 미치는 요소로 이 논문에서는 화염의 형상을 분석하였다. 화염의 길이는 API code와 jet fire 모델이 유사한 값을 보였으며, 화염은 지면에 더 많은 영향을 미치는 것으로 분석되었다.

  • PDF

도로터널 화재시 열부력이 제연용 제트팬 댓수에 미치는 영향에 대한 해석적 연구 (A numerical study on effects of thermal buoyance force on number of jet fans for smoke control)

  • 유지오;신현준
    • 한국터널지하공간학회 논문집
    • /
    • 제15권3호
    • /
    • pp.301-310
    • /
    • 2013
  • 현재 도로터널에는 화재시 임계풍속을 유지할 수 있도록 제트팬을 설치하고 있으며, 제트팬 댓수는 임계풍속을 유지하기 위한 유동저항, 자연풍에 의한 환기저항, 열부력에 의한 환기저항을 고려하여 산정한다. 그러나, 국내의 경우, 제트팬 댓수 산정시 열부력은 고려하지 않고 있는 실정이다. 이에 본 연구에서는 열부력이 제트팬 댓수에 미치는 영향을 검토하기 위해서 터널연장(500, 750, 1000, 1500, 2000, 3500 m) 및 경사도(-1.0, -1.5, -2.0%)를 변수로 하여 화재성장곡선에 따른 비정상상태의 수치 시뮬레이션을 수행하였으며, 열기류의 평균온도 및 열부력에 의한 압력손실을 검토하여 열부력이 제트팬 댓수에 미치는 영향을 검토하였다. 이에 본 연구에서는 화재로 인한 열부력을 고려하는 경우에 제트팬 댓수의 증가가 필요하며, 특히, 설계화재강도를 100 MW로 하는 경우에는 본 해석조건의 모든 범위에서 열부력에 의한 압력손실이 차량저항에 의한 압력손실의 최대치보다 증가하며, 현행설계기준을 적용하는 경우보다. 최소 2~11대의 제트팬 대수의 증가가 필요한 것으로 분석되었다. 따라서 제연용 제트팬 용량 산정시 열부력에 대한 고려가 반드시 필요한 것으로 나타났다.

부력을 받는 확산화염에 대한 수치 시뮬레이션 (Numerical Simulation of Buoyant Diffusion Flame)

  • 오창보;이의주
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.234-237
    • /
    • 2008
  • A direct numerical simulation (DNS) code suitable for the prediction of buoyant jet diffusion flames was developed in this study. The thermodynamic and transport properties were evaluated using CHEMKIN package to enhance the prediction performance of the developed DNS code. A two dimensional simulations were performed for the jet diffusion flames in normal and zero-gravity conditions where the Froude numbers are 5 and infinity, respectively. The simulated buoyant jet diffusion flame in normal gravity showed that the unsteady and dynamic motion although the reynolds number is low (400). It was identified that the flame in normal gravity flickered periodically. The periodic motion of the flame disappeared in zero-gravity condition. The dynamic motion of the buoyant jet diffusion flame could be well understood by comparing the flame structures obtained by the simulations of normal and zero-gravity conditions.

  • PDF

터널내 열차 화재시 효과적인 구난역 제연 설비를 위한 수치 해석 연구 (A Numerical Study on Effective Smoke-Control System of a Rescue Station in a Tunnel Fire)

  • 양성진;원찬식;허남건;차철현
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.575-578
    • /
    • 2006
  • In designing smoke-control system of rescue station in train tunnel, a purpose is to prevent a disaster by proposing the jet fan operation together with smoke-control curtain in tunnel fire. This study has investigated the relationship of the Heat Release Rate(HRR) and a adequate ventilation velocity to control the fire propagation in tunnel fire, and has improved the effect of the smoke-control curtain on preventing the flow of pollutants. In this study, Computational Fluid Dynamics(CFD) simulations with ST AR-CD(ver 3.24) were carried out on predicting the fire spreading and the flow of pollutants, considering jet fan operations and effect of smoke-control curtain. Our simulation domain is the full scale model of the 'DAEGWALLYEONG' 1st tunnel. The results represent that ventilation operation can control the fire spreading and pollutants effectively to prevent a disaster.

  • PDF

Application of reinforcement learning to fire suppression system of an autonomous ship in irregular waves

  • Lee, Eun-Joo;Ruy, Won-Sun;Seo, Jeonghwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.910-917
    • /
    • 2020
  • In fire suppression, continuous delivery of water or foam to the fire source is essential. The present study concerns fire suppression in a ship under sea condition, by introducing reinforcement learning technique to aiming of fire extinguishing nozzle, which works in a ship compartment with six degrees of freedom movement by irregular waves. The physical modeling of the water jet and compartment motion was provided using Unity 3D engine. In the reinforcement learning, the change of the nozzle angle during the scenario was set as the action, while the reward is proportional to the ratio of the water particle delivered to the fire source area. The optimal control of nozzle aiming for continuous delivery of water jet could be derived. Various algorithms of reinforcement learning were tested to select the optimal one, the proximal policy optimization.

수소가스사고의 피해범위 (Hazard Distance from Hydrogen Accidents)

  • 조영도
    • 한국가스학회지
    • /
    • 제16권1호
    • /
    • pp.15-21
    • /
    • 2012
  • 수소가스의 제트 누출에 의한 확산, 화재, 그리고 폭발에 의한 위험 범위를 분석하고, 안전거리 기준을 설정하기 위한 위험거리를 확산, 화재, 그리고 폭발에 대한 단순한 예측 식들을 제시하였다. 핀홀에 의한 누출과 같은 소량 수소가스 누출속도에 있어서 피해거리는 제트누출 확산에 의한 피해거리가 제트화재에 의한 피해거리보다 크며, 압력의 제곱근에 그리고 누출 홀의 직경에 비례하고 이는 수 십 미터에 이른다. 배관의 완전 파손 또는 저장 탱크의 큰 홀 발생과 같은 대량의 수소가스 누출속도에서는 제트화재의 피해거리가 개방공간의 가스운 폭발에 의한 피해거리보다 크며, 수 백 미터에 이른다. 수소충전소와 건물과의 최소이격거리 즉 안전거리 설정 기준을 대량 수소가스누출 사고시나리오를 기반으로 한다면, 도심지에 수소충전소는 안전거리 기준을 만족시키기 어려울 것이다. 따라서 대량의 수소가스 누출사고를 안전장치들을 통하여 예방하고, 안전거리 기준을 소량의 수소가스누출사고 기준으로 설정 할 수 있다. 그러나 대량누출 가능성이 있는 경우 학교와 병원 등 인구밀집 건물은 수 백 미터의 안전거리를 유지하여야 한다.

도로터널 환기/제연 시스템 시뮬레이션 (A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL)

  • 박종택;원찬식;허남건;차철현
    • 한국전산유체공학회지
    • /
    • 제11권4호
    • /
    • pp.20-25
    • /
    • 2006
  • In the present study, flow characteristics inside a road tunnel are simulated for the ventilation flows due to jet fan system and flows induces by the traffic. Traffic ventilation is numerically simulated by multiple reference frame. From the results of steady state simulation of tunnel ventilation, it is found that the proper ventilation is achieved by the designed jet fan system along with ventilating flow induced by the traffic. A transient simulation is also performed for the case of vehicle fire in the tunnel reversing the direction of rotation of some fans. The results suggest that the heat and smoke can be controlled by the proper changing of fan operation mode. The present results can be used to design proper ventilation system and effective smoke control system as well.