Analysis of Interaction Between Recirculating Flow Near The Jet Fan and The Backlayer of Smoke in a Road Tunnel

도로터널에서 제트팬 근처의 재순환유동과 연기 역류현상의 상호작용 분석

  • 김창균 ((주)한국수력원자력, 팔당댐 발전) ;
  • 유진웅 (강원대학교 기계메카트로닉스공학부 기계공학전공) ;
  • 김성준 (강원대학교 공과대학 기계메카트로닉스공학부)
  • Published : 2005.02.28

Abstract

A numerical analysis was done for a tunnel fire in a 1000m road tunnel. A cartesian coordinate was adopted to make a computational grid sytem which has 448,000 computational cells. A transient flow phenomena in the tunnel was simulated by the commercial code of PHEONICS from the ignition of fire to 600 seconds by the interval of 100 seconds. Total computational time of about 44 hours was required to get a convered solution in each time step. The purpose of this research is to analyze of the backlayering pheonomena and recirculation flow in a tunnel. The compuational results say that the backlayering does not happens near the fire of vehicle in this case because the vehicle fire is located at the outside of recirculation zone of flow ocuured near the jet fan. In this research, onset of backlayering pheonomena could be escaped if jet fan is set 95m in front of the the fire of vehicle.

Keywords