• Title/Summary/Keyword: Isolation Level

Search Result 798, Processing Time 0.022 seconds

On component isolation of conceptual advanced reactors

  • Shrestha, Samyog;Kurt, Efe G.;Prakash, Arun;Irfanoglu, Ayhan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2974-2988
    • /
    • 2022
  • Implementation of component isolation in nuclear industry is challenging due to gaps in research and the lack of specific guidelines. In this study, parameters affecting component-level isolation of advanced reactor vessels are identified based on a representative numerical model with explicit consideration of nonlinear soil-structure interaction (SSI). The objective of this study is to evaluate the effectiveness of, and to identify potential limitations of using conventional friction pendulum bearings to seismically isolate vessels. It is found that slender vessels or components are particularly vulnerable to rotational accelerations at the isolation interface, which are caused by rotation of the sub-structure and by excitation of higher modes in the horizontal direction of the seismically isolated system. Component isolation is found to be more effective for relatively stiffer vessels and at sites with stiff soil. Considering that conventional isolators are deficient in resisting axial tension, it is observed that the optimum location for supporting a component to achieve seismic isolation, is at a cross-sectional plane passing through the center of mass of the vessel. These findings are corroborated by numerous simulations of the response of seismically isolated reactor vessels at different nuclear power plant sites subject to a variety of ground motions.

Combining approach in Fault Detection and Isolation for GPS applications

  • Chey, Jay-Won;Jee, Gyu-In;Lee, Jang-Gyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1949-1952
    • /
    • 2004
  • GPS is widely used for outdoor positioning in many applications. But it is not suitable for positioning in an obstacle environment such as urban area, tunnels and so on, due to variable signal level. So new technology of the positioning is required to provide the consistent error level regardless of any changes in any environment. Abrupt changes of GPS signal can be detected by various fault detection and isolation methods. Conventional FDI (Fault Detection and Isolation) methods are categorized into two approaches. One approach is the snapshot method that uses measurements only at present step. The other approach is the filtering method that uses measurements stacked from previous step to present step. The FDI result of the snapshot method can be considered reliable independently with previous results and the FDI result of the filtering method is more reliable and detection time is a little longer. Therefore combining approach of two methods is proposed for increasing FDI performance in this paper. Three approaches that are the snapshot method, the filtering method and the combining method are compared to show the probability of correct FDI in simulations. The combining approach presents best result of FDI among them and shows the consistent accuracy irrespective of any changes in outdoor environment.

  • PDF

The Design of a Sub-Harmonic Dual-Gate FET Mixer

  • Kim, Jeongpyo;Lee, Hyok;Park, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • In this paper, a sub-harmonic dual-gate FET mixer is suggested to improve the isolation characteristic between LO and RF ports of an unbalanced mixer. The mixer was designed by using single-gate FET cascode structure and driven by the second harmonic component of LO signal. A dual-gate FET mixer has good isolation characteristic since RF and LO signals are injected into gatel and gate2, respectively. In addition, the isolation characteristic of a sub-harmonic mixer is better than that of a fundamental mixer due to the large frequency separation between the LO and RF frequencies. As RF power was -30 ㏈m and LO power was 0 ㏈m, the designed mixer yielded the -47.17 ㏈m LO-to-RF leakage power level, 10 ㏈ conversion gain, -2.5 ㏈m OIP3, -12.5 ㏈m IIP3 and -1 ㏈m 1 ㏈ gain compression point. Since the LO-to-RF leakage power level of the designed mixer is as good as that of a double-balanced mixer, the sub-harmonic dual-gate FET mixer can be utilized instead.

A Performance Isolation Mechanism Considering SLA in High Available Heterogeneous Cluster Web Systems (SLA를 고려한 클러스터 기반 고가용성 이질 웹 시스템의 성능 분리 기법)

  • Kang, Chang-Hoon;Park, Kie-Jin;Kim, Sung-Soo
    • The KIPS Transactions:PartA
    • /
    • v.12A no.7 s.97
    • /
    • pp.613-620
    • /
    • 2005
  • To provide reliable differentiated service for internet clients, many studies on differentiated service are widely done. According to the types of the request of the clients in cluster-based web systems, SLA (Service Level Agreement) between service provider and the clients is considered. In this Paper, we study primary-backup web switch in the web systems that distribute the request of clients to each of web servers and also study performance isolation and admission control schemes of heterogeneous web systems which distinguish the servers into each different function domains. We analyze the availability, the response time and the performance of admission control through various simulated experiments on the proposed web systems.

Debates on the isolation distances to segregate fields with GM crops from fields with non-GM crops for the establishment of their coexistence (GM과 non-GM 작물의 공존제도의 정착을 위한 포장의 격리거리에 관한 고찰)

  • Lee, Shin-Woo
    • Journal of Plant Biotechnology
    • /
    • v.36 no.3
    • /
    • pp.261-267
    • /
    • 2009
  • The coexistence policy of GM and non-GM crops is still on the debates in EU since “the recommendation on guidelines for the development of national strategies and best practices to ensure the coexistence of GM crops with conventional and organic farming” has been reported in 2003. The major issues are maximum tolerance level of GMO admixture and minimum isolation distances of GM fields with others including conventional, organic and seeds production. Majority of member states in EU proposed that the tolerance level of GMO admixture must be more strictly controlled, in particular in the fields for organic crops and seeds production. To this end, it was proposed that minimum isolation distances to segregate GM crops from fields with organic crops and seeds production need to be further extended than those of conventional crops since cross pollination with other crops adjacent GM fields is known as the most prevalent source for GMO contamination. In these circumstances, it is strongly suggested that the current legislations need to be revised including the minimum isolation distances of fields for each species before field cultivation for a commercial GM crop is approved for the first time in South Korea.

High-Isolation SPDT RF Switch Using Inductive Switching and Leakage Signal Cancellation

  • Ha, Byeong Wan;Cho, Choon Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.411-414
    • /
    • 2014
  • A switch is one of the most useful circuits for controlling the path of signal transmission. It can be added to digital circuits to create a kind of gate-level device and it can also save information into memory. In RF subsystems, a switch is used in a different way than its general role in digital circuits. The most important characteristic to consider when designing an RF switch is keeping the isolation as high as possible while also keeping insertion loss as low as possible. For high isolation, we propose leakage signal cancellation and inductive switching for designing a singlepole double-throw (SPDT) RF switch. By using the proposed method, an isolation level of more than 23 dB can be achieved. Furthermore, the heterojunction bipolar transistor (HBT) process is used in the RF switch design to keep the insertion loss low. It is demonstrated that the proposed RF switch has an insertion loss of less than 2 dB. The RF switch operates from 1 to 8 GHz based on the $0.18-{\mu}m$ SiGe HBT process, taking up an area of $0.3mm^2$.

Seismic protection of LNG tanks with reliability based optimally designed combined rubber isolator and friction damper

  • Khansefid, Ali;Maghsoudi-Barmi, Ali;Khaloo, Alireza
    • Earthquakes and Structures
    • /
    • v.16 no.5
    • /
    • pp.523-532
    • /
    • 2019
  • Different types of gas reservoir such as Liquid Natural Gas (LNG) are among the strategic infrastructures, and have great importance for any government or their private owners. To keep the tank and its contents safe during earthquakes especially if the contents are of hazardous or flammable materials; using seismic protection systems such as base isolator can be considered as an effective solution. However, the major deficiency of this system can be the large deformation in the isolation level which may lead to the failure of bearing system. In this paper, as a solution, the efficacy of an optimally designed combined vibration control system, the combined laminated rubber isolator and rotational friction damper, is investigated to evaluate the enhancement of an existing metal tank response under both far- and near-field earthquakes. Responses like impulsive and convective accelerations, base shear, and sloshing height are studied herein. The probabilistic framework is used to consider the uncertainties in the structural modeling, as well as record-to-record variability. Due to the high calculation cost of probabilistic methods, a simplified structural model is used. By using the Mont-Carlo simulation approach, it is revealed that this combined isolation system is a highly reliable system which provides considerable enhancement in the performance of reservoir, not only leads to the reduction of probability of catastrophic failure of the tank but also decrease the reservoir damage during the earthquake. Moreover, the relative displacement of the isolation level is controlled very well by this combined system.

Dynamic characteristics of combined isolation systems using rubber and wire isolators

  • Lee, Seung-Jae;Truong, Gia Toai;Lee, Ji-Eon;Park, Sang-Hyun;Choi, Kyoung-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1071-1084
    • /
    • 2022
  • The present study aims to investigate the dynamic properties of a novel isolation system composed of separate rubber and wire isolators. The testing program comprised pure compressive, pure-shear, compressive-stress dependence, and shear-strain dependence tests that used full-scale test specimens according to ISO 22762-1. A total of 22 test specimens were fabricated and investigated. Among the tests, the pure compressive test was a destructive test that reached up to the failure stage, whereas the others were nondestructive tests before the failure stage. Similar to the pure-shear test, at each compressive-stress level in the compressive dependence test or at each shear-strain level in the shear-strain dependence test, the cyclic loading was conducted for three cycles. In the nondestructive tests, examination of the dynamic shear properties in the X-direction was independent of the Y-direction. The test results revealed that the increase in the shear strain increased the energy dissipation but decreased the damping ratio, whereas the increase in the compressive stress increased the damping ratio. In addition, a macro model was developed to simulate the load-displacement response of the isolation systems, and the prediction results were consistent with the experimental results.

A Study on the Architectural Planning of Material Handling System for the Airborne Infection Isolation Hospitals (호흡기 감염 격리병원의 물류시스템 계획에 관한 연구)

  • Choi, Kwangseok;Kwon, Soon Jung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.2
    • /
    • pp.63-72
    • /
    • 2017
  • Purpose: The purpose of this study is to review the material handling system of the Airborne Infection Isolation Hospitals which is the one of the key elements of infection control and to improve the basic data for the planning and design of those facilities. Methods: Research was conducted by literature reviews and case studies for the material handling system of domestic and foreign Isolation hospitals. Results: The result of this study can be summarized into three points. First, a general isolation unit and a high level isolated unit need to be distinguished in terms of efficiency and safety. In particular, it is desirable that a high level isolated unit have to completely separate clean and soiled circulations, and soiled corridor should be installed by those means. By doing this, the medical staff can observe patient rooms and supply clean materials directly in the clean zone without wearing PPE, so that safety and work efficiency can be improved at the same time. Second, for the safe disposal of wastes, it is desirable to install a dedicated sterilizer per ward and sterilize it at least in the ward. In addition, It is desirable to install a central waste treatment room and a dedicated soiled corridor in consideration of the inadequate handling capacity and emergency situation. Third, the characteristics of material flow chart in the negative pressured isolation hospitals and the corresponding material handling system have been presented. Implications: Infection control is very important in safety, but it is necessary to respond to the symptoms of the patient.

Anomalous Subthreshold Characteristics for Charge Trapping NVSM at memory states. (기억상태에 있는 전하트랩형 비휘발성 반도체 기억소자의 하위문턱이상전류특성)

  • 김병철;김주연;서광열;이상배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.13-16
    • /
    • 1998
  • An anomalous current characteristics which show the superposition of a low current level and high current level at the subthreshold region when SONOSFETs are in memory states were investigated. We have assumed this phenomena were resulted from the effect of parasitic transistors by LOCOS isolation and were modeled to a parallel equivalent circuit of one memory transistor and two parasitic transistors. Theoretical curves are well fitted in measured log I$_{D}$-V$_{G}$ curves independent of channel width of memory devices. The difference between low current level and high current level is apparently decreased with decrease of channel width of devices because parasitic devices dominantly contribute to the current conduction with decrease of channel width of memory devices. As a result, we concluded that the LOCOS isolation has to selectively adopt in the design of process for charge-trap type NVSM.VSM.

  • PDF