사고각에 따른 자속구속형 전류제한기의 전류제한특성 (Current Limiting Characteristics of Flux-Lock Type High-TC Superconducting Fault Current Limiter According to Fault Angles)

  • 박형민;임성훈;조용선;박충렬;한병성;최효상;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.12-14
    • /
    • 2004
  • We investigated current limiting characteristics of the flux-lock type high-Tc superconcting fault current limiter(HTSC-FCL) according to fault angles. The Flux-lock type HTSC-FCL consists of primary and the secondary copper coils that are wound in parallel each other through the iron core and YBCO thin flim. In this paper, the current limiting characteristics of the flux-lock type HTSC-FCL according to fault angles in case of the subtractive and additive polarity windings were compared and analyzed. From the results, the flux-lock type HTSC-FCL could limit more quickly fault current as the fault angles increased irrespective of the fault angles. On the other hand, the initial power burden of HTSC element after a fault happened increased as the fault angles increased. In addition, it was confirmed that the resistance of flux-lock type HTSC-FCL in case of subtractive polarity winding was more increased than that of additive polarity winding and that the peak current of fault current in case of subtractive polarity winding was larger than that of the additive polarity winding case.

  • PDF

권선계자형 자기 기어의 고 토크 리플 회전자에 대한 분석 및 개선 (Torque Ripple Improving and Analysis of Coil-winding Rotor of Magnetic Gear)

  • 박의종;김용재
    • 한국전자통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.259-266
    • /
    • 2020
  • 자기 기어는 기계식 기어와 동일하게 기어의 특성을 나타내면서 각 회전자가 접촉하지 않아 마찰에 의한 소음 및 발열, 유지보수문제에서 기계식 기어보다 유리하다. 또한 권선계자를 사용하는 회전자를 적용할 경우 기어의 출력조절은 물론, 기어비 및 위급상황에서 자체적인 구동차단까지 가능하여 자기 기어의 활용가능성은 무한하다. 하지만 권선계자를 사용할 경우 영구자석과 철심간의 흡인력에 의한 코깅토크가 나타나게 되고 이는 회전자의 진동을 유발하는 토크 리플성분의 증가로 이어진다. 따라서 본 논문에서는 권선계자를 사용하는 회전자의 토크 리플을 저감하기 위해 회전자의 다양한 형상을 분석하였으며, 자기 기어의 토크 리플을 저감하기 위한 최적의 형상을 제시하였다.

Using Quality of Life Scales with Nutritional Relevance after Gastrectomy: a Challenge for Providing Personalized Treatment

  • Lee, Seung Soo;Yu, Wansik;Chung, Ho Young;Kwon, Oh Kyoung;Lee, Won Kee
    • Journal of Gastric Cancer
    • /
    • 제17권4호
    • /
    • pp.342-353
    • /
    • 2017
  • Purpose: This study evaluated the changes in nutritional status based on quality of life (QoL) item-level analysis to determine whether individual QoL responses might facilitate personal clinical impact. Materials and Methods: This study retrospectively evaluated QoL data obtained by the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire-Core 30 (QLQ-C30) and Quality of Life Questionnaire-Stomach (QLQ-STO22) as well as metabolic-nutritional data obtained by bioelectrical impedance analysis and blood tests. Patients were assessed preoperatively and at the 5-year follow-up. QoL was analyzed at the level of the constituent items. The patients were categorized into vulnerable and non-vulnerable QoL groups for each scale based on their responses to the QoL items and changes in the metabolic-nutritional indices were compared. Results: Multiple shortcomings in the metabolic-nutritional indices were observed in the vulnerable groups for nausea/vomiting (waist-hip ratio, degree of obesity), dyspnea (hemoglobin, iron), constipation (body fat mass, percent body fat), dysphagia (body fat mass, percent body fat), reflux (body weight, hemoglobin), dry mouth (percent body fat, waist-hip ratio), and taste (body weight, total body water, soft lean mass, body fat mass). The shortcomings in a single index were observed in the vulnerable groups for emotional functioning and pain (EORTC QLQ-C30) and for eating restrictions (EORTC QLQ-STO22). Conclusions: Long-term postoperative QoL deterioration in emotional functioning, nausea/vomiting, pain, dyspnea, constipation, dysphagia, reflux, eating restrictions, dry mouth, and taste were associated with nutritional shortcomings. QoL item-level analysis, instead of scale-level analysis, may help to facilitate personalized treatment for individual QoL respondents.

결선방향에 따른 자속구속형 전류제한기의 퀜치 회복 의존도 해석 (Analysis on Quench Recovery Dependence of A Flux-Lock Type SFCL According to the Winding Directions)

  • 정수복;조용선;최명호;최효상
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.113-117
    • /
    • 2008
  • 본 논문에서는 결선방향에 따른 자속구속형 전류제한기의 전류제한 및 회 특성에 대해 분석하였다. 자속구속형 초전도 한류기는 초전도 소자와 직렬로 연결된 2차 권선과 병렬로 연결된 1 2차 권선으로 구성되어 있다. 1 2차 권선의 결선방향에 따른 가극 결선과 가극 결선을 갖는 자속구속형 전류제한기를 저항형 전류제한기와 비교하여 분석하였다. 전류제한 및 회복특성은 1 2차 권선의 결선방향에 의존한다. 가극 결선을 갖는 자속구속형 전류제한기의 퀜치시간은 감극 결선이나 저항형 전류제한기보다 더 빠르다는 것을 확인하였다. 초전도 소자에서 소비되는 에너지는 $W= VIt=I^2Rt$으로 표현할 수 있다. 결선 방향에 따라 초전도 소자에서 소비되는 에너지의 차이는 초전도 소자에서 부담하는 전압의 차이 때문이라는 것을 확인할 수 있었다.

회전자속형 초전도 전원장치의 박막상에서의 2차원 자장분포 및 전류 특성 해석 (Analysis of the Magnetic Field Distribution and the Current Characteristics of Rotating Type Low Tc Superconducting Power Supply)

  • 심기덕;김호민;윤용수;추용;한태수;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.343-345
    • /
    • 1998
  • By computer simulation, the pattern of magnetic field distribution on the Nb-foil of a rotating flux type superconducting power supply has been calculated. Using the results, the current pumping rate has been calculated and compared with the results obtained by the experiment. The experiment has been executed with small-size flux-rump in the environment of LN2 and LHe in order to compare the pattern of magnetic filed in the superconducting state and in the normal state. Five hall-sensor was located on the center, right side, left-side, upper side, lower side of the Nb-foil in order to obtain more accurate pattern of the magnetic field generated by rotating pole. In the simulation, the effects of the excitation-magnet and the iron core located at the inner-side and circumference of the magnet have been considered. By comparing the data from the experiment and the results from the simulation, the size of normal spot estimated. At the same time, by calculating the linkage flux, the current-pumping-rate has been obtained. Consequently, the results obtained from experiment and simulation coincided as expected.

  • PDF

4병렬 팬케이크 권선을 사용한 1 MVA 단상 고온초전도 변압기의 설계 및 제작 (Design and Fabricate a 1 MVA Single Phase HTS Transformer with Four Parallel Pancake Windings)

  • 김우석;김성훈;이상진;최경달;주형길;홍계원;한진호;한송엽;송회석;박정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.723-725
    • /
    • 2003
  • The result of design and Partial fabrication of a 1 MVA single phase high temperature superconducting(HTS) transformer for power distributions are presented in this paper. The HTS windings are wound as double pancake windings which have advantages of uniform distribution of high voltage over the windings. the rated primary and secondary voltages are 22.9 kV and 6.6 kV respectively. Four HTS tapes are wound in parallel for secondary windings considering the rated currents of the transformer. The HTS windings will be cooled down to 65 K by natural convection of sub-cooled liquid nitrogen using a single-staged GM-cryocooler in order to make the stability of the HTS windings better. The iron core is designed as shell type and isolated from the liquid nitrogen by an FRP cryostat which have a room temperature bore. After the complete fabrication of the total HTS transformer system, performance test of the transformer will be carried out.

  • PDF

3상 일체화된 자속구속형 전류제한기의 동작특성 (Operational Characteristics in integrated Three-Phase a Flux-Lock type SFCL according to Fault Conditions)

  • 이나영;최효상;정수복;이상일;남긍현;임성훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.467-470
    • /
    • 2006
  • Superconducting fault current(SFCLs) are expected to improve not only reliability but also stability of real power systems. The analysis on the single line-to-ground fault current of the integrated three phase flux-lock type SFCL, which consists of three flux-lock reactor wound on an iron core in each single phase and three YBCO thin films, was investigated in current limiting operating characteristics. We compared additive polarity winding with the subtractive one in the flux lock reactor. Its turns ratio each phase between the primary and the secondary coils is 63:42. When a single line-to-ground fault occurred in any phase, the peak value of line current in the fault phase of the additive polarity winding increased up to 31.44[A] during first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to 81.77[A] under the same conditions. This is because the current flow between the primary and the secondary windings becomes to be additive or subtractive in each winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to ground fault.

  • PDF

자기동이 가능한 2상 SRM의 자기적 특성에 관한 연구 (The Study on Magnetic Characteristics of 2 Phase SRM with Self-Starting Capability)

  • 오석규;이치우
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.47-54
    • /
    • 2008
  • 중소형 가변속 전동기구는 성능뿐만 아니라 가격경쟁력이 중요한 요인 중에 하나로 인식되고 있다. 가변속 전동기중에서 SRM을 중소형 전동기로서 적용할 때 가격경쟁력 측면에서 보면 단상이나 2상이 적합하다. 그러한 이유로 전력용량이 비교적 작은 가정용 전동기구에는 거의 단상 혹은 2상 SRM이 연구되고 있다. 그러나 단상 SRM은 근본적으로 발생토오크가 블연속적이여서 운전특성이 떨어지고 자기동능력이 없어 기동을 위한 보조적인 장치가 항상 필요하다. 또한 2상 SRM은 연속적인 토오크를 만들 수 있으나 기동에 관해서는 아 도 많은 문제점을 안고 있다. 제안한 2상 6/3 SRM은 일반적인 다른 SRM과 달리 고정자 철심에 자속의 교번 없이 구동이 가능하여 철손을 줄일 수 있다. 또한 일반적으로 단상과 2상의 SRM에서 실용화에 있어서 가장 장애가 된 자기동이 안 되는 문제점을 회전자의 비대칭 형상을 이용하여 구동특성의 저하없이 자기동 능력을 가지게 되었다. 특성 해석을 위해 FEM 해석프로그램인 FLUX2D을 사용하였다.

배전자동화 개폐기 내장형 광 전류 및 광 전압 센서에 관한 연구 (A Study on Optical Current Sensor and Voltage Sensor for automation of power distribution)

  • 양승국;오상기;박해수;김인수;김요희;홍창희
    • 한국정보통신학회논문지
    • /
    • 제6권1호
    • /
    • pp.89-98
    • /
    • 2002
  • 본 연구에서는 광계측 기술을 이용하여 배전자동화 개폐기 내에서 발생하는 전자 계측장치의 절연문제 및 측정오차의 문제점을 개선하기 위하여 배선자동화개폐기 내장형 광전류 및 광전압센서를 연구하였다. 자기광학 효과(magneto optic effect)인 페러데이효과(Faraday effect)를 이용하여 최적의 광전류 센서를 설계 제작하여 높은 전류까지 선형성을 유지시키고 다른 상의 전류에 대한 유도현상을 최소로 하기 위해 순철 코아를 사용하여 광전류 센서를 일체화시켜 설계 제작하였다. 설계내에서 결정의 굴절률 및 방위각의 변화에 의해 생기는 전기광학효과(electrooptic effect)인 포켈스 효과(pockels effect)를 이용하여 광전압센서를 구성하였으며 배전 자동화용 개폐기의 협소한 내부구조를 고려하여 공간전계방식을 채택하였다. 또한 다심의 광섬유를 개폐기와 외부의 신호처리 단말기와 연결하기 위하여 기밀형 멀티 광커넥터를 설계 자작하여 접속 손실 및 가스 누설 시험을 하였다. 전기적 특성시험에서 광 전류센서에서는 인가 전류에 대한 선형 특성은 20A 에서 700A까지 변동 오차 2.5% 이내의 선형성을 유지하였으며, 광전압센서에 있어서 인가 전압에 대한 선형 특성은 6.6kV에서 19.8kV까지 거의 변동 오차가 1% 이내로 우수한 선형 특성을 나타냈다.

과전압에 의한 변압기 철공진 분석 및 방지대책 (Analysis for the Ferroresonance on the Transformer by Overvoltage and Prevention Measures)

  • 윤동현;신동열;차한주
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1543-1550
    • /
    • 2015
  • Ferroresonance is a non-linear vibrational phenomenon that is generated by the electrical interaction of the inductance component with the capacitor component of a certain capacitance as the device of the inductance component such as a transformer is saturated due to the degradation, the waveform distortion of current and voltage, and the oscillation of overcurrent and overvoltage in a system. Recently, ferroresonance was generated from the waveform distortion of current and voltage, or the overvoltage or undervoltage phenomenon caused by the nature of an electrical power system and design technology of the transformer in the three phase transformer system. Hence, in general, ferroresonance analyzed by converting to the LC equivalent circuit. However, in general, the aforementioned analytical method only applies to the resonance phenomenon that is generated by the interaction of the capacitance of bussbar and grounding, and switching as the capacitor component with PT and the transformer as the inductance component in a system. Subsequently, the condition where ferroresonance was generated since overvoltage was supplied as line voltage to the phase voltage and thus the iron core is saturated due to the interconnection between grounded and ungrounded systems could not be analyzed when single phase PT was connected in a ${\Delta}$/Y connection system. In this study, voltage swell in the configuration of grounded circuit of a step-up transformer with the ${\Delta}-{\Delta}$ connection linked to PT for control power and the ferroresonance generated by overvoltage when the line voltage of the ${\Delta}-{\Delta}$ connection was connected to the phase voltage of the grounded Y-Y connection were analyzed using PSCAD / EMTDC through the failure case of the transformer caused by ferroresonance in the system with the ${\Delta}-{\Delta}$/Y-Y connection, and subsequently, the preventive measure of ferroresonance was proposed.